Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
medRxiv ; 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39252896

RESUMEN

The OpenOximetry Repository is a structured database storing clinical and lab pulse oximetry data, serving as a centralized repository and data model for pulse oximetry initiatives. It supports measurements of arterial oxygen saturation (SaO2) by arterial blood gas co-oximetry and pulse oximetry (SpO2), alongside processed and unprocessed photoplethysmography (PPG) data and other metadata. This includes skin color measurements, finger diameter, vital signs (e.g., arterial blood pressure, end-tidal carbon dioxide), and arterial blood gas parameters (e.g., acid-base balance, hemoglobin concentration). Data contributions are encouraged. All data, from desaturation studies to clinical trials, are collected prospectively to ensure accuracy. A common data model and standardized protocols for consistent archival and interpretation ensure consistent data archival and interpretation. The dataset aims to facilitate research on pulse oximeter performance across diverse human characteristics, addressing performance issues and promoting accurate pulse oximeters. The initial release includes controlled lab desaturation studies (CLDS), with ongoing updates planned as further data from clinical trials and CLDS become available.

2.
Respir Care ; 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39242173

RESUMEN

BACKGROUND: Mechanical power applied to the respiratory system (MPRS) is associated with ventilator-induced lung injury (VILI) and ARDS mortality. Absent automated ventilator MPRS measurements, the alternative is clinically unwieldy equations. However, simplified surrogate formulas are now available and accurately reflect values produced by airway pressure-volume curves. This retrospective, observational study examined whether the surrogate pressure-control equation alone could accurately assess mortality risk in ARDS subjects managed almost exclusively with volume-control ventilation.METHODS: 948 subjects were studied in whom invasive mechanical ventilation and implementation of ARDSNet ventilator protocols commenced ≤ 24hr after ARDS onset, and who survived > 24hr. MPRS was calculated as 0.098 x respiratory frequency x VT x (PEEP + driving pressure [PDR]). MPRS was assessed as a risk factor for hospital mortality, and compared between non-survivors and survivors across Berlin Definition classifications. In addition, mortality was compared across 4 MPRS thresholds associated with VILI or mortality (ie. 15, 20, 25 and 30 J/m).RESULTS: MPRS was associated with increased mortality risk: Odds Ratio (95% CI) of 1.06 (1.04-1.07) per J/m, P<0.001). Median MPRS differentiated non-survivors from survivors in Mild (24.7 vs. 18.5 J/m, respectively, P==0.034); Moderate (25.7 vs. 21.3 J/m, P<0.001); and Severe ARDS (28.7 vs. 23.5 J/m, P<0.001). Across 4 MPRS thresholds mortality increased from 23-29% when MPRS was < threshold vs. 38-51% when MPRS was > threshold (P<0.001). In the > cohort the Odds Ratio (95%CI) increased from 2.03 (1.34-3.12) to 2.51 (1.87-3.33).CONCLUSION: The pressure control surrogate formula is sufficiently accurate to assess mortality in ARDS, even when using volume control ventilation. In our subjects when MPRS exceeds established cut-off values for VILI or mortality risk, we found mortality risk consistently increased by a factor of > 2.0.

3.
JAMA ; 331(24): 2075-2076, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38809524

RESUMEN

This Viewpoint discusses the recent use of forced nitrogen inhalation as capital punishment in Alabama and describes the body of evidence indicating that forced nitrogen inhalation is an inhumane practice.


Asunto(s)
Pena de Muerte , Hipoxia , Nitrógeno , Tortura , Humanos , Pena de Muerte/legislación & jurisprudencia , Pena de Muerte/métodos , Nitrógeno/administración & dosificación , Estados Unidos , Administración por Inhalación , Hipoxia/etiología
4.
Anesth Analg ; 139(1): 15-24, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38470828

RESUMEN

BACKGROUND: There is a large global deficit of anesthesia providers. In 2016, the World Federation of Societies of Anaesthesiologists (WFSA) conducted a survey to count the number of anesthesia providers worldwide. Much work has taken place since then to strengthen the anesthesia health workforce. This study updates the global count of anesthesia providers. METHODS: Between 2021 and 2023, an electronic survey was sent to national professional societies of physician anesthesia providers (PAPs), nurse anesthetists, and other nonphysician anesthesia providers (NPAPs). Data included number of providers and trainees, proportion of females, and limited intensive care unit (ICU) capacity data. Descriptive statistics were calculated by country, World Bank income group, and World Health Organization (WHO) region. Provider density is reported as the number of providers per 100,000 population. RESULTS: Responses were obtained for 172 of 193 United Nations (UN) member countries. The global provider density was 8.8 (PAP 6.6 NPAP 2.3). Seventy-six countries had a PAP density <5, whereas 66 countries had a total provider density <5. PAP density increased everywhere except for high- and low-income countries and the African region. CONCLUSIONS: The overall size of the global anesthesia workforce has increased over time, although some countries have experienced a decrease. Population growth and differences in which provider types that are counted can have an important impact on provider density. More work is needed to define appropriate metrics for measuring changes in density, to describe anesthesia cadres, and to improve workforce data collection processes. Effort to scale up anesthesia provider training must urgently continue.


Asunto(s)
Anestesiólogos , Anestesiología , Salud Global , Humanos , Anestesiólogos/tendencias , Anestesiólogos/provisión & distribución , Anestesiología/tendencias , Anestesiología/educación , Femenino , Fuerza Laboral en Salud/tendencias , Enfermeras Anestesistas/tendencias , Enfermeras Anestesistas/provisión & distribución , Masculino , Encuestas de Atención de la Salud , Recursos Humanos/tendencias , Encuestas y Cuestionarios , Anestesia/tendencias , Países en Desarrollo
5.
Anesth Analg ; 137(5): 934-942, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37862392

RESUMEN

Capnography is now recognized as an indispensable patient safety monitor. Evidence suggests that its use improves outcomes in operating rooms, intensive care units, and emergency departments, as well as in sedation suites, in postanesthesia recovery units, and on general postsurgical wards. Capnography can accurately and rapidly detect respiratory, circulatory, and metabolic derangements. In addition to being useful for diagnosing and managing esophageal intubation, capnography provides crucial information when used for monitoring airway patency and hypoventilation in patients without instrumented airways. Despite its ubiquitous use in high-income-country operating rooms, deaths from esophageal intubations continue to occur in these contexts due to incorrect use or interpretation of capnography. National and international society guidelines on airway management mandate capnography's use during intubations across all hospital areas, and recommend it when ventilation may be impaired, such as during procedural sedation. Nevertheless, capnography's use across high-income-country intensive care units, emergency departments, and postanesthesia recovery units remains inconsistent. While capnography is universally used in high-income-country operating rooms, it remains largely unavailable to anesthesia providers in low- and middle-income countries. This lack of access to capnography likely contributes to more frequent and serious airway events and higher rates of perioperative mortality in low- and middle-income countries. New capnography equipment, which overcomes cost and context barriers, has recently been developed. Increasing access to capnography in low- and middle-income countries must occur to improve patient outcomes and expand universal health care. It is time to extend capnography's safety benefits to all patients, everywhere.


Asunto(s)
Anestesia , Capnografía , Humanos , Unidades de Cuidados Intensivos , Anestesia/efectos adversos , Monitoreo Fisiológico , Quirófanos
6.
J Clin Monit Comput ; 37(6): 1441-1449, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37266710

RESUMEN

Anemia and hypoxemia are common clinical conditions that are difficult to study and may impact pulse oximeter performance. Utilizing an in vitro circulation system, we studied performance of three pulse oximeters during hypoxemia and severe anemia. Three oximeters including one benchtop, one handheld, and one fingertip device were selected to reflect a range of cost and device types. Human blood was diluted to generate four hematocrit levels (40%, 30%, 20%, and 10%). Oxygen and nitrogen were bubbled through the blood to generate a range of oxygen saturations (O2Hb) and the blood was cycled through the in vitro circulation system. Pulse oximeter saturations (SpO2) were paired with simultaneously-measured O2Hb readings from a reference CO-oximeter. Data for each hematocrit level and each device were least-squares fit to a 2nd-order equation with quality of each curve fit evaluated using standard error of the estimate. Bias and average root mean square error were calculated after correcting for the calibration difference between human and in vitro circulation system calibration. The benchtop oximeter maintained good accuracy at all but the most extreme level of anemia. The handheld device was not as accurate as the benchtop, and inaccuracies increased at lower hematocrit levels. The fingertip device was the least accurate of the three oximeters. Pulse oximeter performance is impacted by severe anemia in vitro. The use of in vitro calibration systems may play an important role in augmenting in vivo performance studies evaluating pulse oximeter performance in challenging conditions.


Asunto(s)
Anemia , Sistema Cardiovascular , Humanos , Oximetría , Oxígeno , Hipoxia , Anemia/diagnóstico
7.
Front Med (Lausanne) ; 10: 1148334, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37138744

RESUMEN

Knowing the target oxygen saturation (SpO2) range that results in the best outcomes for acutely hypoxemic adults is important for clinical care, training, and research in low-income and lower-middle income countries (collectively LMICs). The evidence we have for SpO2 targets emanates from high-income countries (HICs), and therefore may miss important contextual factors for LMIC settings. Furthermore, the evidence from HICs is mixed, amplifying the importance of specific circumstances. For this literature review and analysis, we considered SpO2 targets used in previous trials, international and national society guidelines, and direct trial evidence comparing outcomes using different SpO2 ranges (all from HICs). We also considered contextual factors, including emerging data on pulse oximetry performance in different skin pigmentation ranges, the risk of depleting oxygen resources in LMIC settings, the lack of access to arterial blood gases that necessitates consideration of the subpopulation of hypoxemic patients who are also hypercapnic, and the impact of altitude on median SpO2 values. This process of integrating prior study protocols, society guidelines, available evidence, and contextual factors is potentially useful for the development of other clinical guidelines for LMIC settings. We suggest that a goal SpO2 range of 90-94% is reasonable, using high-performing pulse oximeters. Answering context-specific research questions, such as an optimal SpO2 target range in LMIC contexts, is critical for advancing equity in clinical outcomes globally.

8.
Anesth Analg ; 137(1): 191-199, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37115721

RESUMEN

BACKGROUND: Anesthesia-related causes contribute to a significant proportion of perioperative deaths, especially in low and middle-income countries (LMICs). There is evidence that complications related to failed airway management are a significant contributor to perioperative morbidity and mortality. While existing data have highlighted the magnitude of airway management complications in LMICs, there are inadequate data to understand their root causes. This study aimed to pilot an airway management capacity tool that evaluates airway management resources, provider practices, and experiences with difficult airways in an attempt to better understand potential contributing factors to airway management challenges. METHODS: We developed a novel airway management capacity assessment tool through a nonsystematic review of existing literature on anesthesia and airway management in LMICs, internationally recognized difficult airway algorithms, minimum standards for equipment, the safe practice of anesthesia, and the essential medicines and health supplies list of Uganda. We distributed the survey tool during conferences and workshops, to anesthesia care providers from across the spectrum of surgical care facilities in Uganda. The data were analyzed using descriptive methods. RESULTS: Between May 2017 and May 2018, 89 of 93 surveys were returned (17% of anesthesia providers in the country) from all levels of health facilities that provide surgical services in Uganda. Equipment for routine airway management was available to all anesthesia providers surveyed, but with a limited range of sizes. Pediatric airway equipment was always available 54% of the time. There was limited availability of capnography (15%), video laryngoscopes (4%), cricothyroidotomy kits (6%), and fiber-optic bronchoscopes (7%). Twenty-one percent (18/87) of respondents reported experiencing a "can't intubate, can't ventilate" (CICV) scenario in the 12 months preceding the survey, while 63% (54/86) reported experiencing at least 1 CICV during their career. Eighty-five percent (74/87) of respondents reported witnessing a severe airway management complication during their career, with 21% (19/89) witnessing a death as a result of a CICV scenario. CONCLUSIONS: We have developed and implemented an airway management capacity tool that describes airway management practices in Uganda. Using this tool, we have identified significant gaps in access to airway management resources. Gaps identified by the survey, along with advocacy by the Association of Anesthesiologists of Uganda, in partnership with the Ugandan Ministry of Health, have led to some progress in closing these gaps. Expanding the availability of airway management resources further, providing more airway management training, and identifying opportunities to support skilled workforce expansion have the potential to improve perioperative safety in Uganda.


Asunto(s)
Anestesiología , Anestésicos , Humanos , Niño , Uganda , Estudios Transversales , Manejo de la Vía Aérea/efectos adversos
9.
Respir Care ; 68(3): 309-319, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35977748

RESUMEN

BACKGROUND: Postextubation stridor (PES) is an imminently life-threatening event. Maximizing patient safety requires a systematic approach to screen patients for PES risk factors and a standardized test to evaluate that risk. This retrospective study of adult subjects was based on quality assurance data including standardized surveillance screening criteria and a volume-based cuff leak test (CLT) to evaluate PES risk among predominantly surgical-trauma and neurotrauma subjects. Data characterizing PES subjects also were collected. METHODS: Data were collected between May 2010-December 2017 for all intubated subjects in our surgical-trauma, neurotrauma, and medical ICUs. Respiratory therapists were trained in performing both PES risk assessment surveillance and a volume-based CLT. A pre hoc cutoff leak volume of < 110 mL defined a true positive test result when associated with PES, and a leak ≥ 110 mL defined a true negative test if PES was absent. Multiple comparisons were analyzed by Kruskal-Wallis tests and dichotomous variables assessed by Fisher exact tests. Alpha was set at 0.05. RESULTS: In 681 pre-extubation CLTs ∼85% produced true-negative results and 15% consisted of true-positive (∼4%), false-negative (∼5%), and false-positive (∼6%) results. Positive and negative predictive values were 0.42 (0.32-0.54) and 0.94 (0.92-0.96), respectively. The PES likelihood ratio was 7.0, and correct classification was 89%. Of the 115 PES incidences occurring in 112 PES cases, 67% were female and 48% had suffered acute brain injury. CONCLUSIONS: Among predominantly surgical-trauma and neurotrauma subjects with a CLT, leak volume of ≥ 110 mL was associated with a PES risk of ∼6%, whereas the risk of PES was 7 times greater when the leak volume was < 110 mL.


Asunto(s)
Intubación Intratraqueal , Ruidos Respiratorios , Adulto , Humanos , Femenino , Masculino , Ruidos Respiratorios/etiología , Estudios Retrospectivos , Intubación Intratraqueal/efectos adversos , Estudios Prospectivos , Medición de Riesgo
11.
Respir Care ; 67(10): 1343-1360, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35501129

RESUMEN

Infection with SARS-CoV-2 in select individuals results in viral sepsis, pneumonia, and hypoxemic respiratory failure, collectively known as COVID-19. In the early months of the pandemic, the combination of novel disease presentation, enormous surges of critically ill patients, and severity of illness lent to early observations and pronouncements regarding COVID-19 that could not be scientifically validated owing to crisis circumstances. One of these was a phenomenon referred to as "happy hypoxia." Widely discussed in the lay press, it was thought to represent a novel and perplexing phenomenon: severe hypoxemia coupled with the absence of respiratory distress and dyspnea. Silent hypoxemia is the preferred term describing an apparent lack of distress in the presence of hypoxemia. However, the phenomenon is well known among respiratory physiologists as hypoxic ventilatory decline. Silent hypoxemia can be explained by physiologic mechanisms governing the control of breathing, breathing perception, and cardiovascular compensation. This narrative review examines silent hypoxemia during COVID-19 as well as hypotheses that viral infection of the central and peripheral nervous system may be implicated. Moreover, the credulous embrace of happy hypoxia and the novel hypotheses proposed to explain it has exposed significant misunderstandings among clinicians regarding the physiologic mechanisms governing both the control of breathing and the modulation of breathing sensations. Therefore, a substantial focus of this paper is to provide an in-depth review of these topics.


Asunto(s)
COVID-19 , COVID-19/complicaciones , Disnea/etiología , Humanos , Hipoxia/epidemiología , Hipoxia/etiología , Pandemias , SARS-CoV-2
12.
Cell Rep Med ; 3(3): 100533, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-35474746

RESUMEN

The rapid pace of the COVID-19 pandemic precluded traditional approaches to evaluating clinical research and guidelines. We highlight notable successes and pitfalls of clinicians' new approaches to managing evidence amidst an unprecedented crisis. In "Era 1" (early 2020), clinicians relied on anecdote and social media, which democratized conversations on guidelines, but also led clinicians astray. "Era 2" (approximately late 2020 to early 2021) saw preprints that accelerated new interventions but suffered from a surfeit of poor-quality data. In the current era, clinicians consolidate the evidentiary gains of Era 2 with living, online clinical guidelines, but the public suffers from misinformation. The COVID-19 pandemic is a laboratory on how clinicians adapt to an absence of clinical guidance amidst an informational and healthcare crisis. Challenges remain as we integrate new approaches to innovations made in the traditional guideline process to confront both the long tail of COVID-19 and future pandemics.


Asunto(s)
COVID-19 , Medios de Comunicación Sociales , Comunicación , Humanos , Pandemias
13.
Respir Care ; 67(2): 252-257, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34772785

RESUMEN

It has long been known that many pulse oximeters function less accurately in patients with darker skin. Reasons for this observation are incompletely characterized and potentially enabled by limitations in existing regulatory oversight. Based on decades of experience and unpublished data, we believe it is feasible to fully characterize, in the public domain, the factors that contribute to missing clinically important hypoxemia in patients with darkly pigmented skin. Here we propose 5 priority areas of inquiry for the research community and actionable changes to current regulations that will help improve oximeter accuracy. We propose that leading regulatory agencies should immediately modify standards for measuring accuracy and precision of oximeter performance, analyzing and reporting performance outliers, diversifying study subject pools, thoughtfully defining skin pigmentation, reporting data transparently, and accounting for performance during low-perfusion states. These changes will help reduce bias in pulse oximeter performance and improve access to safe oximeters.


Asunto(s)
Oximetría , Oxígeno , Humanos , Hipoxia/diagnóstico , Hipoxia/etiología , Pigmentación de la Piel
14.
Respir Care ; 66(11): 1649-1656, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34493608

RESUMEN

BACKGROUND: The generation of excessive inspiratory muscle pressure (Pmus) during assisted mechanical ventilation in patients with respiratory failure may result in acute respiratory muscle injury and/or fatigue, and exacerbate ventilator-induced lung injury. A readily available noninvasive surrogate measure of Pmus may help in titrating both mechanical ventilation and sedation to minimize these risks. This bench study explored the feasibility and accuracy of using a ventilator's expiratory pause hold function to measure Pmus across multiple operators. METHODS: A standardized technique for executing a brief (<1 s) expiratory pause maneuver was used to measure the airway occlusion pressure change (Δ Paw) by using 3 simulated Pmus (Δ Pmus: 5, 10, 15 cm H2O) under (1) pressure support ventilation (0, 10, 15 cm H2O), (2) volume and pressure-regulated volume ventilation, (3) flow and pressure-triggering, and (4) varying levels of PEEP and pressure-rise time. Individual and grouped measurements were made by 4-7 clinicians on 3 different ventilators. The concordance between occlusion Δ Paw and Δ Pmus was arbitrarily set at ≤ 2 cm H2O. Data were evaluated by using analysis of variance and the Tukey-Kramer posttest. Correlation was assessed by using the Pearson R test; bias and precision were assessed by using the Bland-Altman method. Alpha was set at 0.05. RESULTS: Grouped expiratory pause maneuver measurements of occlusion Δ Paw across simulated Δ Pmus, mode and level of ventilatory support showed reasonable concordance, regardless of the ventilator used. Occlusion Δ Paw accuracy frequently decreased by ∼3 cm H2O when both pressure support ventilation and Δ Pmus reached 15 cm H2O. Expiratory pause maneuver accuracy was not affected by trigger mechanism and/or sensitivity, PEEP, or the post-trigger pressurization rate. In general, only small differences in Δ Paw occurred among the individual operators. CONCLUSIONS: The expiratory pause maneuver generally provided reproducible, stable approximations of Δ Pmus across ventilators and ventilator settings, and a range of simulated effort. Technique standardization produced relatively consistent results across multiple operators. The expiratory pause maneuver seemed feasible for general use in monitoring inspiratory effort during assisted mechanical ventilation.


Asunto(s)
Respiración Artificial , Ventiladores Mecánicos , Animales , Humanos , Ratones , Respiración con Presión Positiva , Respiración , Músculos Respiratorios
15.
Pediatr Emerg Care ; 37(10): 519-525, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34591810

RESUMEN

ABSTRACT: Most children with coronavirus disease 2019 (COVID-19) infection are asymptomatic or have mild disease. About 5% of infected children will develop severe or critical disease. Rapid identification and treatment are essential for children who are critically ill with signs and symptoms of respiratory failure, septic shock, and multisystem inflammatory syndrome in children. This article is intended for pediatricians, pediatric emergency physicians, and individuals involved in the emergency care of children. It reviews the current epidemiology of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in children, summarizes key aspects of clinical assessment including identification of high-risk patients and manifestations of severe disease, and provides an overview of COVID-19 management in the emergency department based on clinical severity.


Asunto(s)
COVID-19 , Niño , Servicio de Urgencia en Hospital , Humanos , SARS-CoV-2 , Síndrome , Síndrome de Respuesta Inflamatoria Sistémica
16.
PLoS Med ; 18(8): e1003749, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34415914

RESUMEN

BACKGROUND: Indicators to evaluate progress towards timely access to safe surgical, anaesthesia, and obstetric (SAO) care were proposed in 2015 by the Lancet Commission on Global Surgery. These aimed to capture access to surgery, surgical workforce, surgical volume, perioperative mortality rate, and catastrophic and impoverishing financial consequences of surgery. Despite being rapidly taken up by practitioners, data points from which to derive the indicators were not defined, limiting comparability across time or settings. We convened global experts to evaluate and explicitly define-for the first time-the indicators to improve comparability and support achievement of 2030 goals to improve access to safe affordable surgical and anaesthesia care globally. METHODS AND FINDINGS: The Utstein process for developing and reporting guidelines through a consensus building process was followed. In-person discussions at a 2-day meeting were followed by an iterative process conducted by email and virtual group meetings until consensus was reached. The meeting was held between June 16 to 18, 2019; discussions continued until August 2020. Participants consisted of experts in surgery, anaesthesia, and obstetric care, data science, and health indicators from high-, middle-, and low-income countries. Considering each of the 6 indicators in turn, we refined overarching descriptions and agreed upon data points needed for construction of each indicator at current time (basic data points), and as each evolves over 2 to 5 (intermediate) and >5 year (full) time frames. We removed one of the original 6 indicators (one of 2 financial risk protection indicators was eliminated) and refined descriptions and defined data points required to construct the 5 remaining indicators: geospatial access, workforce, surgical volume, perioperative mortality, and catastrophic expenditure. A strength of the process was the number of people from global institutes and multilateral agencies involved in the collection and reporting of global health metrics; a limitation was the limited number of participants from low- or middle-income countries-who only made up 21% of the total attendees. CONCLUSIONS: To track global progress towards timely access to quality SAO care, these indicators-at the basic level-should be implemented universally as soon as possible. Intermediate and full indicator sets should be achieved by all countries over time. Meanwhile, these evolutions can assist in the short term in developing national surgical plans and collecting more detailed data for research studies.


Asunto(s)
Anestesia/normas , Salud Global/normas , Procedimientos Quirúrgicos Obstétricos/normas , Indicadores de Calidad de la Atención de Salud/estadística & datos numéricos , Consenso
17.
Cell Rep Med ; 2(8): 100375, 2021 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-34337553

RESUMEN

The speed and scale of new information during the COVID-19 pandemic required a new approach toward developing best practices and evidence-based clinical guidance. To address this need, we produced COVIDProtocols.org, a collaborative, evidence-based, digital platform for the development and dissemination of COVID-19 clinical guidelines that has been used by over 500,000 people from 196 countries. We use a Collaborative Writing Application (CWA) to facilitate an expedited expert review process and a web platform that deploys content directly from the CWA to minimize any delays. Over 200 contributors have volunteered to create open creative-commons content that spans over 30 specialties and medical disciplines. Multiple local and national governments, hospitals, and clinics have used the site as a key resource for their own clinical guideline development. COVIDprotocols.org represents a model for efficiently launching open-access clinical guidelines during crisis situations to share expertise and combat misinformation.


Asunto(s)
COVID-19/terapia , Práctica Clínica Basada en la Evidencia/métodos , Difusión de la Información/métodos , Guías de Práctica Clínica como Asunto , COVID-19/transmisión , Humanos , Pandemias/prevención & control , Guías de Práctica Clínica como Asunto/normas , SARS-CoV-2/patogenicidad
18.
Hum Resour Health ; 19(1): 93, 2021 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-34321021

RESUMEN

BACKGROUND: One of the biggest barriers to accessing safe surgical and anesthetic care is lack of trained providers. Uganda has one of the largest deficits in anesthesia providers in the world, and though they are increasing in number, they remain concentrated in the capital city. Salary is an oft-cited barrier to rural job choice, yet the size and sources of anesthesia provider incomes are unclear, and so the potential income loss from taking a rural job is unknown. Additionally, while salary augmentation is a common policy proposal to increase rural job uptake, the relative importance of non-monetary job factors in job choice is also unknown. METHODS: A survey on income sources and magnitude, and a Discrete Choice Experiment examining the relative importance of monetary and non-monetary factors in job choice, was administered to 37 and 47 physician anesthesiologists in Uganda, between May-June 2019. RESULTS: No providers worked only at government jobs. Providers earned most of their total income from a non-government job (50% of income, 23% of working hours), but worked more hours at their government job (36% of income, and 44% of working hours). Providers felt the most important job attributes were the quality of the facility and scope of practice they could provide, and the presence of a colleague (33% and 32% overall relative importance). These were more important than salary and living conditions (14% and 12% importance). CONCLUSIONS: No providers accepted the salary from a government job alone, which was always augmented by other work. However, few providers worked only nongovernment jobs. Non-monetary incentives are powerful influencers of job preference, and may be leveraged as policy options to attract providers. Salary continues to be an important driver of job choice, and jobs with fewer income generating opportunities (e.g. private work in rural areas) are likely to need salary augmentation to attract providers.


Asunto(s)
Anestesia , Médicos , Servicios de Salud Rural , Selección de Profesión , Humanos , Renta , Uganda
19.
Respir Care ; 66(9): 1380-1388, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33888589

RESUMEN

BACKGROUND: ARDS mortality is lower among subjects participating in randomized controlled trials (RCTs) compared to subjects in observational studies. Excluding potential subjects with inordinately high mortality risk is necessary to prevent masking the impact of potentially effective treatments. We inquired whether observed mortality differed between RCT-eligible and RCT-ineligible subjects managed with varying degrees of lung-protective ventilation in a non-research setting. METHODS: This single-center, retrospective, observational study utilized quality assurance data for monitoring lung-protective ventilation practices based upon National Institutes of Health ARDS Network (ARDSNet) protocols. Between 2002 and 2017, 1,975 subjects meeting the 1994 consensus criteria for acute lung injury/ARDS (later reclassified by the Berlin definition) were prospectively identified and classified as RCT-eligible or RCT-ineligible on the basis of the original ARDSNet exclusion criteria for comorbidities or moribund condition. Demographic and physiologic data from the day of ARDS onset and outcome data were studied. Survival was modeled with a mixed-effect Cox proportional hazard model adjusted for age, both illness and lung injury severity plateau pressure, and formal use of the ARDSNet ventilator protocol. The primary outcome of interest was all-cause mortality during the first 90 d following onset of ARDS. RESULTS: Day 90 mortality was 27.6% in RCT-eligible subjects versus 50.4% in RCT-ineligible subjects (hazard ratio 0.47 [95% CI 0.41-0.54], P < .001). Regardless of eligibility or ineligibility, achieving a plateau pressure ≤ 30 cm H2O was associated with lower mortality. Overall, mortality risk was lower in subjects managed by protocol versus clinician-directed lung-protective ventilation (hazard ratio 0.60 [95% CI 0.52-0.69], P < .001), even among those in whom plateau pressure was ≤ 30 cm H2O (hazard ratio 0.64 [95% CI 0.54-0.76], P < .001). CONCLUSIONS: Mortality in non-research, RCT-eligible subjects was substantially lower compared to RCT-ineligible subjects. Managing non-research patients with ARDS by keeping plateau pressure ≤ 30 cm H2O and formal use of a lung-protective ventilation protocol significantly reduces mortality risk.


Asunto(s)
Síndrome de Dificultad Respiratoria , Humanos , Pulmón , Respiración Artificial , Síndrome de Dificultad Respiratoria/terapia , Volumen de Ventilación Pulmonar , Ventiladores Mecánicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA