Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Orthop Surg Res ; 19(1): 562, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39267139

RESUMEN

BACKGROUND: Anatomical reduction and stable fixation of complex tibial plateau fractures remain challenging in clinical practice. This study examines the efficacy of using 3D printing technology combined with customized plates for treating these fractures. METHODS: We retrospectively analyzed 22 patients treated with 3D printing and customized plates at the Orthopedic Department of the Central Hospital affiliated with Shenyang Medical College from September 2020 to January 2023. These patients were matched with 22 patients treated with traditional plates with similar baseline characteristics. Patients were divided into an experimental group (3D-printed models and customized plates) and a control group (traditional plates). The control group underwent traditional surgical methods, while the experimental group had a preoperative 3D model and customized plates for surgical planning. We compared baseline characteristics and recorded various indicators, including preoperative preparation time, surgical time, intraoperative blood loss, number of intraoperative fluoroscopies, hospital stay duration, fracture healing time, complications, knee joint range of motion (ROM), Rasmussen anatomical and functional scores, and HSS scores. RESULTS: All surgeries were successful with effective follow-up. The experimental group had shorter surgical time, less intraoperative blood loss, and fewer intraoperative fluoroscopies (P < 0.05). At 6 months and 1 year postoperatively, the experimental group had better knee joint HSS scores than the control group. Preoperative preparation time and total hospital stay were shorter in the control group (P < 0.05). There were no significant differences in fracture healing time and follow-up duration between groups. The experimental group showed better knee joint flexion angles (P < 0.05). Rasmussen scores showed no statistical difference between groups (P > 0.05). The incidence of complications was slightly lower in the experimental group but not significantly different. CONCLUSION: 3D printing technology combined with customized plates for complex tibial plateau fractures enables precise articular surface reduction, significantly shortens surgical time, and reduces intraoperative blood loss. This method improves knee joint function, offering a more effective treatment option.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Impresión Tridimensional , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Resultado del Tratamiento , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Tempo Operativo , Rango del Movimiento Articular , Fracturas de la Meseta Tibial
2.
J Int Med Res ; 52(8): 3000605241274524, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39216075

RESUMEN

This case report describes a woman in her 70s who presented with a 3-month history of hip pain and inability to walk. Upon admission, she was diagnosed with the extremely rare condition of complete femoral head disappearance. A comprehensive examination was conducted to determine the cause and devise an effective treatment strategy, taking the patient's medical history into account. Through interdisciplinary discussions, occult infection and other potential causes were ruled out. The femoral head disappearance was ultimately determined to be due to wear, ischemia, and absorption following a fracture. After informing the patient of the diagnosis and treatment plan, total hip arthroplasty was proposed. This case highlights the rarity and severity of femoral head disappearance in patients with femoral neck fractures, emphasizing the effectiveness of total hip arthroplasty and appropriate joint prostheses in managing such cases. This case has significant implications for clinical diagnosis, treatment, and complication prevention. The report also discusses the causes of acquired femoral head disappearance, relevant diagnostic assessments, and alternative treatment options.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Cuello Femoral , Cabeza Femoral , Humanos , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/diagnóstico por imagen , Femenino , Cabeza Femoral/cirugía , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/patología , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos
3.
Medicine (Baltimore) ; 103(35): e39369, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39213232

RESUMEN

BACKGROUND: This study aims to evaluate the therapeutic efficacy of combined treatment with pulsed electromagnetic fields (PEMFs) and platelet-rich plasma (PRP) injection in improving pain and functional mobility among patients with early-stage knee osteoarthritis (KOA). We hypothesize that this combined therapy can yield superior treatment outcomes. METHODS: Based on the different treatment regimens, we divided 48 patients diagnosed with Kellgren-Lawrence grades I-III KOA into 3 groups: the PRP group, the PEMFs group, and the PRP + PEMFs group. Each subtype of KOA patients was randomly assigned to different treatment groups. In the PRP group, patients received intra-articular injections of leukocyte-rich platelet-rich plasma once a month for 3 consecutive months. In the PEMFs group, patients receive low-frequency PEMFs irradiation therapy with a frequency of 30 Hz and intensity of 1.5 mT, once daily, 5 times a week, for a consecutive treatment period of 12 weeks. In the PRP + PEMFs group, patients receive both of the aforementioned treatment protocol. The treatment effects on patients are evaluated at baseline and at weeks 4, 8, and 12 post-treatment. Assessment parameters include visual analog scale for pain, Western Ontario and McMaster Universities Osteoarthritis Index, Lequesne Index score, and knee joint range of motion. RESULTS: From the 4th to the 12th week of treatment, the visual analog scale scores, Western Ontario and McMaster Universities Osteoarthritis Index scores, and Lequesne index scores of patients in all 3 groups gradually decreased, while knee joint mobility gradually increased (P < .05). At weeks 4, 8, and 12 after treatment, the PRP combined with PEMFs group showed significantly better scores compared to the PRP group and the PEMFs group, with statistically significant differences (P < .05). A total of 7 patients experienced adverse reactions such as knee joint swelling, low-grade fever, and worsening knee joint pain after treatment, all of which disappeared within 1 week after treatment. The incidence of complications did not differ significantly among the 3 groups (P = .67). CONCLUSION: PRP, PEMFs, and the combination of PRP and PEMFs therapy all effectively alleviate knee joint pain and improve joint function. However, compared to single treatment modalities, the combined therapy of PRP and PEMFs demonstrates more pronounced efficacy.


Asunto(s)
Magnetoterapia , Osteoartritis de la Rodilla , Plasma Rico en Plaquetas , Humanos , Osteoartritis de la Rodilla/terapia , Masculino , Femenino , Persona de Mediana Edad , Terapia Combinada , Magnetoterapia/métodos , Anciano , Resultado del Tratamiento , Dimensión del Dolor , Inyecciones Intraarticulares
4.
PLoS One ; 19(5): e0302839, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38696506

RESUMEN

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Asunto(s)
Hilos Ortopédicos , Fijación Interna de Fracturas , Fracturas Conminutas , Rótula , Humanos , Masculino , Femenino , Adulto , Rótula/cirugía , Rótula/lesiones , Fracturas Conminutas/cirugía , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Estudios Retrospectivos , Persona de Mediana Edad , Rango del Movimiento Articular , Resultado del Tratamiento , Fracturas Óseas/cirugía , Curación de Fractura , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Adulto Joven , Tornillos Óseos , Anclas para Sutura
5.
Front Surg ; 11: 1383401, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38817945

RESUMEN

Background: In recent years, 3D printing technology has made significant strides in the medical field. With the advancement of orthopedics, there is an increasing pursuit of high surgical quality and optimal functional recovery. 3D printing enables the creation of precise physical models of fractures, and customized personalized steel plates can better realign and more comprehensively and securely fix fractures. These technologies improve preoperative diagnosis, simulation, and planning for complex limb fractures, providing patients with better treatment options. Patients and methods: Five typical cases were selected from a pool of numerous patients treated with 3D printing technology combined with personalized custom steel plates at our hospital. These cases were chosen to demonstrate the entire process of printing 3D models and customizing individualized steel plates, including details of the patients' surgeries and treatment procedures. Literature reviews were conducted, with a focus on highlighting the application of 3D printing technology combined with personalized custom steel plates in the treatment of complex limb fractures. Results: 3D printing technology can produce accurate physical models of fractures, and personalized custom plates can achieve better fracture realignment and more comprehensive and robust fixation. These technologies provide patients with better treatment options. Conclusion: The use of 3D printing models and personalized custom steel plates can improve preoperative diagnosis, simulation, and planning for complex limb fractures, realizing personalized medicine. This approach helps reduce surgical time, minimize trauma, enhance treatment outcomes, and improve patient functional recovery.

6.
BMC Surg ; 24(1): 157, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755649

RESUMEN

BACKGROUND: Fractures involving the posterior acetabulum with its rich vascular and neural supply present challenges in trauma orthopedics. This study evaluates the effectiveness of 3D printing technology with the use of custom-made metal plates in the treatment of posterior wall and column acetabular fractures. METHODS: A retrospective analysis included 31 patients undergoing surgical fixation for posterior wall and column fractures of the acetabulum (16 in the 3D printing group, utilizing 3D printing for a 1:1 pelvic model and custom-made plates based on preoperative simulation; 15 in the traditional group, using conventional methods). Surgical and instrument operation times, intraoperative fluoroscopy frequency, intraoperative blood loss, fracture reduction quality, fracture healing time, preoperative and 12-month postoperative pain scores (Numeric Rating Scale, NRS), hip joint function at 6 and 12 months (Harris scores), and complications were compared. RESULTS: The surgical and instrument operation times were significantly shorter in the 3D printing group (p < 0.001). The 3D printing group exhibited significantly lower intraoperative fluoroscopy frequency and blood loss (p = 0.001 and p < 0.001, respectively). No significant differences were observed between the two groups in terms of fracture reduction quality, fracture healing time, preoperative pain scores (NRS scores), and 6-month hip joint function (Harris scores) (p > 0.05). However, at 12 months, hip joint function and pain scores were significantly better in the 3D printing group (p < 0.05). Although the incidence of complications was lower in the 3D printing group (18.8% vs. 33.3%), the difference did not reach statistical significance (p = 0.433). CONCLUSION: Combining 3D printing with individualized custom-made metal plates for acetabular posterior wall and column fractures reduces surgery and instrument time, minimizes intraoperative procedures and blood loss, enhancing long-term hip joint function recovery. CLINICAL TRIAL REGISTRATION: 12/04/2023;Trial Registration No. ChiCTR2300070438; http://www.chictr.org.cn .


Asunto(s)
Acetábulo , Placas Óseas , Fijación Interna de Fracturas , Fracturas Óseas , Impresión Tridimensional , Humanos , Estudios Retrospectivos , Acetábulo/cirugía , Acetábulo/lesiones , Masculino , Femenino , Adulto , Persona de Mediana Edad , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Resultado del Tratamiento , Fracturas Óseas/cirugía , Tempo Operativo , Adulto Joven , Diseño de Prótesis , Anciano
7.
Sci Rep ; 13(1): 22667, 2023 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-38114629

RESUMEN

This study investigated the effectiveness of 3D printing technology in combination with personalized custom-made steel plates in the treatment of complex distal intra-articular trimalleolar fractures, with the aim of providing a new approach to improve ankle joint function in patients. The 48 patients with complex distal intra-articular trimalleolar fractures included in the study were randomly divided into two groups: the personalized custom-made steel plate group (n = 24) and the conventional steel plate group (n = 24). A comparison was made between the two groups in terms of preoperative preparation time, hospitalization duration, surgical time, fracture reduction and internal fixation time, intraoperative fluoroscopy instances, surgical incision length, fracture healing time, follow-up duration, degree of fracture reduction, ankle joint functional recovery, and the occurrence of complications. The personalized steel plate group exhibited longer preoperative preparation time and hospitalization duration compared to the conventional steel plate group (p < 0.001). However, the personalized steel plate group demonstrated significantly shorter surgical duration, time for fracture reduction and internal fixation, reduced intraoperative fluoroscopy frequency, and a shorter overall surgical incision length (p < 0.001). Both groups displayed similar fracture healing times and follow-up durations (p > 0.05). The personalized steel plate group showed a higher rate of successful fracture reduction (87.5% vs. 79.2%, p > 0.05) and a lower incidence of complications (8.3% vs. 20.8%, p = 0.22), although these differences did not reach statistical significance. Furthermore, the personalized steel plate group exhibited superior ankle joint function scores during follow-up compared to the conventional steel plate group (p < 0.05). By utilizing 3D printing technology in conjunction with personalized custom-made steel plates, personalized treatment plans are provided for patients with complex comminuted tri-malleolar ankle fractures, enabling safer, more efficient, and satisfactory orthopedic surgeries.


Asunto(s)
Fracturas de Tobillo , Fracturas Intraarticulares , Herida Quirúrgica , Humanos , Tobillo , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/cirugía , Fijación Interna de Fracturas , Impresión Tridimensional , Acero , Resultado del Tratamiento , Estudios Retrospectivos
8.
J Orthop Surg Res ; 18(1): 669, 2023 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-37689739

RESUMEN

BACKGROUND: ue to the lack of consensus on the optimal surgical treatment for distal radius fractures (DRF) in elderly patients over 65 years old, the purpose of this study was to compare the efficacy of external fixation (EF) with Kirschner wires and volar locking plate (VLP) in the treatment of DRF through a retrospective cohort study. We hypothesized that there would be no significant difference in overall complications and functional recovery between the two methods. METHODS: We retrospectively analyzed 62 patients over 65 years old who underwent surgical treatment for C-type DRF between 2019 and 2022. Based on the different treatment methods, they were divided into the EF group and the VLP group. General data, inpatient data, and postoperative complications during follow-up were recorded. The X-ray images before surgery, after surgery, and at the last follow-up were analyzed, and the results of wrist motion range, Gartland-Werley wrist joint score, and DASH score were evaluated 6 months after surgery for both groups. RESULT: Thirty patients underwent closed reduction and external fixation combined with Kirschner wire fixation, while 32 underwent open reduction and VLP fixation. The EF group had significantly shorter operation time, intraoperative blood loss, injury-to-surgery time, and hospital stay compared to the VLP group (all p < 0.001). At the last follow-up, the radiographic parameters (ulnar variance and radial inclination) and wrist joint function (wrist dorsiflexion and forearm supination) were better in the VLP group than in the EF group (p = 0.04, p = 0.01, p = 0.001, p = 0.02, respectively). However, there was no significant difference in overall Gartland-Werley wrist joint score, DASH score, and incidence of postoperative complications between the two groups (p = 0.31, p = 0.25, p = 0.47, respectively). CONCLUSION: For patients aged 65 and above with distal radius fractures (DRF) of type C, VLP and external fixation with Kirschner wires yield comparable functional outcome and complications rate at the short term. However, VLP allowed restoration of better radiological parameters.


Asunto(s)
Hilos Ortopédicos , Fracturas de la Muñeca , Anciano , Humanos , Estudios Retrospectivos , Fijadores Externos , Fijación de Fractura , Complicaciones Posoperatorias
9.
Artículo en Inglés | MEDLINE | ID: mdl-12016015

RESUMEN

A selective, sensitive and accurate liquid chromatographic method with UV and fluorescence detection was developed, validated and applied for the determination of fluoroquinolones in human plasma. The effects of mobile phase composition, ion-pair and competing-base reagents, buffers, pH, and acetonitrile concentrations were investigated on the separation of six quinolones (cinoxacin, levofloxacin, ciprofloxacin, gatifloxacin, moxifloxacin and trovafloxacin). Sample preparation was carried out by adding internal standard and displacing agent and processing by ultrafiltration. This method uses ultraviolet and fluorescence detection and separation using a C(18) column. The recovery, selectivity, linearity, precision, and accuracy of the method were evaluated from spiked human plasma samples. The method was successfully applied to patient plasma samples in support of a levofloxacin pharmacokinetic study.


Asunto(s)
Antiinfecciosos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Levofloxacino , Ofloxacino/aislamiento & purificación , Antiinfecciosos/sangre , Antiinfecciosos/farmacocinética , Calibración , Humanos , Concentración de Iones de Hidrógeno , Ofloxacino/sangre , Ofloxacino/farmacocinética , Concentración Osmolar , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Fluorescencia , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA