Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Lab Med ; 40(2): 122-130, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31650728

RESUMEN

BACKGROUND: Automated cellular analyzers are expected to improve the analytical performance in body fluid (BF) analysis. We evaluated the analytical performance of three automated cellular analyzers and established optimum reflex analysis guidelines. METHODS: A total of 542 BF samples (88 cerebrospinal fluid [CSF] samples and 454 non-CSF samples) were examined using manual counting and three automated cellular analyzers: UniCel DxH 800 (Beckman Coulter), XN-350 (Sysmex), and UF-5000 (Sysmex). Additionally, 2,779 BF analysis results were retrospectively reviewed. For malignant cell analysis, the receiver operating characteristic (ROC) curve was used, and the detection of high fluorescence-BF cells (HF-BFs) using the XN-350 analyzer was compared with cytology results. RESULTS: All three analyzers showed good agreement for total nucleated cell (TNC) and red blood cell (RBC) counts, except for the RBC count in CSF samples using the UniCel DxH 800. However, variable degrees of differences were observed during differential cell counting. For malignant cell analysis, the area under the curve was 0.63 for the XN-350 analyzer and 0.76 for manual counting. We established our own reflex analysis guidelines as follows: HF-BFs <0.7/100 white blood cells (WBCs) is the criterion for quick scans with 100× magnification microscopic examination as a rule-out cut-off, while HF-BFs >83.4/100 WBCs or eosinophils >3.8% are the criteria for mandatory double check confirmation with 1,000× magnification examination. CONCLUSIONS: The three automated analyzers showed good analytical performances. Application of reflex analysis guidelines is recommended for eosinophils and HF-BFs, and manual confirmation is warranted.


Asunto(s)
Líquidos Corporales/citología , Recuento de Células/métodos , Área Bajo la Curva , Automatización , Recuento de Células/instrumentación , Citometría de Flujo , Humanos , Límite de Detección , Curva ROC , Reproducibilidad de los Resultados
2.
Biol Pharm Bull ; 27(11): 1883-6, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15516743

RESUMEN

In order to determine on the anti-complement activity of triterpenes, following eleven triterpenoides were isolated from the fruits of the Zizyphus jujuba MILL: ceanothane-type triterpenes: colubrinic acid (1), zizyberenalic acid (11); lupane-type triterpenes: alphitolic acid (2), 3-O-cis-p-coumaroyl alphitolic acid (3), 3-O-trans-p-coumaroyl alphitolic acid (4), betulinic acid (7), betulonic acid (9); and oleanane-type triterpenes: 3-O-cis-p-coumaroyl maslinic acid (5), 3-O-trans-p-coumaroyl maslinic acid (6), oleanolic acid (8), oleanonic acid (10). These compounds were examined for their anti-complement activity against the classical pathway of the complement system. Among them, compounds 5, 6, and 8 exhibited significant anti-complement activity with IC(50) values of 101.4, 143.9, and 163.4 microM, respectively, whereas the ceanothane-type and the lupane-type triterpenes were inactive. This suggests that the oleanane-structure plays an important role in inhibiting the hemolytic activity of human serum against erythrocytes.


Asunto(s)
Proteínas Inactivadoras de Complemento/farmacología , Triterpenos/farmacología , Ziziphus/química , Cromatografía Líquida de Alta Presión , Proteínas Inactivadoras de Complemento/química , Proteínas Inactivadoras de Complemento/aislamiento & purificación , Vía Clásica del Complemento/efectos de los fármacos , Frutas , Humanos , Técnicas In Vitro , Masculino , Triterpenos/química , Triterpenos/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA