Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(1)2022 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-36616854

RESUMEN

The performance of microelectromechanical system (MEMS) inertial measurement units (IMUs) is susceptible to many environmental factors. Among different factors, temperature is one of the most challenging issues. This report reveals the bias stability analysis of an ovenized MEMS gyroscope. A micro-heater and a control system exploiting PID/PWM were used to compensate for the bias stability variations of a commercial MEMS IMU from BOSCH "BMI 088". A micro-heater made of gold (Au) thin film is integrated with the commercial MEMS IMU chip. A custom-designed micro-machined glass platform thermally isolates the MEMS IMU from the ambient environment and is vacuum sealed in the leadless chip carrier (LCC) package. The BMI 088 built-in temperature sensor is used for temperature sensing of the device and the locally integrated heater. The experimental results reveal that the bias repeatability of the devices has been improved significantly to achieve the target specifications, making the commercial devices suitable for navigation. Furthermore, the effect of vacuum-packaged and non-vacuum-packaged devices was compared. It was found that the bias repeatability of vacuum-packaged devices was improved by more than 60%.


Asunto(s)
Artículos Domésticos , Sistemas Microelectromecánicos , Cultura , Vidrio , Oro
2.
Micromachines (Basel) ; 12(8)2021 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-34442524

RESUMEN

In this paper, a new design technique is presented to estimate and reduce the cross-axis sensitivity (CAS) in a single-drive multi-axis microelectromechanical systems (MEMS) gyroscope. A simplified single-drive multi-axis MEMS gyroscope, based on a mode-split approach, was analyzed for cross-axis sensitivity using COMSOL Multiphysics. A design technique named the "ratio-matching method" of drive displacement amplitudes and sense frequency differences ratios was proposed to reduce the cross-axis sensitivity. Initially, the cross-axis sensitivities in the designed gyroscope for x and y-axis were calculated to be 0.482% and 0.120%, respectively, having an average CAS of 0.301%. Using the proposed ratio-matching method and design technique, the individual cross-axis sensitivities in the designed gyroscope for x and y-axis were reduced to 0.018% and 0.073%, respectively. While the average CAS was reduced to 0.045%, showing a reduction rate of 85.1%. Moreover, the proposed ratio-matching method for cross-axis sensitivity reduction was successfully validated through simulations by varying the coupling spring position and sense frequency difference variation analyses. Furthermore, the proposed methodology was verified experimentally using fabricated single-drive multi-axis gyroscope.

3.
Micromachines (Basel) ; 11(12)2020 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-33255312

RESUMEN

In this paper, a COMSOL Multiphysics-based methodology is presented for evaluation of the microelectromechanical systems (MEMS) gyroscope. The established finite element analysis (FEA) model was successfully validated through a comparison with analytical and Matlab/Simulink analysis results. A simplified single-drive, 3-axis MEMS gyroscope was analyzed using a mode split approach, having a drive resonant frequency of 24,918 Hz, with the x-sense, y-sense, and z-sense being 25,625, 25,886, and 25,806 Hz, respectively. Drive-mode analysis was carried out and a maximum drive-displacement of 4.0 µm was computed for a 0.378 µN harmonic drive force. Mechanical sensitivity was computed at 2000 degrees per second (dps) input angular rate while the scale factor for roll, pitch, and yaw was computed to be 0.014, 0.011, and 0.013 nm/dps, respectively.

4.
Micromachines (Basel) ; 10(6)2019 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-31226741

RESUMEN

This paper presents the design, fabrication, and characterization of a highly sensitive, single drive multi-axis gyroscope. The multi-axis gyroscope allows for a wide bandwidth in all three axes (X, Y, Z) and exhibits high linearity. The fabricated multi-axis gyroscope was fabricated with a structural thickness of 30 µm and packaged at 100 mtorr using wafer level packaging. The fabricated multi-axis gyroscope has a small footprint of 1426 × 1426 µm2, making it one of the smallest multi-axis gyroscopes. A custom printed circuit board (PCB) was designed for the evaluation of the multi-axis gyroscope. The experimental results demonstrate that the gyroscope has a high sensitivity of 12.56   µ V / dps ,   17.13   µ V / dps and 25.79   µ V / dps in the roll (X-sense), pitch (Y-sense) and yaw (Z-sense) modes respectively. The scale-factor non-linearity of the gyroscope is less than 0.2 % for roll and pitch mode and 0.001 % for the yaw mode, in the full-scale range of ± 1500   deg / s . The multi-axis gyroscope demonstrates an angle random walk of 2.79   dps / Hz , 2.14   dps / Hz , and   1.42   dps / Hz , for the roll, pitch and yaw rate with the in-run bias stability 1.62   deg / s , 1.14   deg / s and 0.84   deg / s respectively.

5.
Micromachines (Basel) ; 9(4)2018 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-30424106

RESUMEN

Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS resonators, using frequency domain analysis. The influence of the applied driving force was studied to evaluate the measurement variations in resonant characteristics, such as the natural frequency and the quality factor of the resonator. To quantify the measurement results, measurement system analysis (MSA) was performed using the analysis of variance (ANOVA) method. The results demonstrate that the resonant frequency ( f r ) is mostly affected by systematic error. However, the quality (Q) factor strongly depends on the applied driving force. To reduce the measurement variations in Q factor, experiments were carried out to study the influence of DC and/or AC driving voltages on the resonator. The results reveal that measurement uncertainties in the quality factor were high for a small electrostatic force.

6.
J Nanosci Nanotechnol ; 15(10): 7624-31, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26726386

RESUMEN

We developed a novel process for synthesizing Si solar cells with improved efficiencies. The process involved the formation of pyramid-like structures on the Si substrate and the deposition and subsequent thermal annealing of an antireflection coating. The process consisted of three main stages. First, pyramid-like structures were textured on the Si substrate by reactive ion etching and subsequently etched using a mixture of HF, HNO3, and deionized water for 300 s. Next, an antireflection coating was deposited on the substrate and was subsequently thermally annealed in a furnace in a N2 atmosphere. After the annealing process, the minority carrier lifetime increased by approximately 40 µs. Further, because of the increase in the minority carrier lifetime and the uniform doping of the substrate, the leakage current decreased. As a result, the efficiency of resulting solar cell increased to 17.24%, in contrast to that of the reference cell, which was only 15.89%. Thus, uniform doping and the thermal annealing of the antireflective coating improved solar cell efficiency.

7.
IET Nanobiotechnol ; 8(1): 37-43, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24888190

RESUMEN

The authors developed a cantilever-arrayed blood pressure sensor array fabricated by (111) silicon bulk-micromachining for the non-invasive and continuous measurement of blood pressure. The blood pressure sensor measures the blood pressure based on the change in the resistance of the piezoresistor on a 5-microm-thick-arrayed perforated membrane and 20-microm-thick metal pads. The length and the width of the unit membrane are 210 and 310 microm, respectively. The width of the insensible zone between the adjacent units is only 10 microm. The resistance change over contact force was measured to verify the performance. The good linearity of the result confirmed that the polydimethylsiloxane package transfers the forces appropriately. The measured sensitivity was about 4.5%/N. The maximum measurement range and the resolution of the fabricated blood pressure sensor were greater than 900 mmHg (= 120 kPa) and less than 1 mmHg (= 133.3 Pa), respectively.


Asunto(s)
Presión Arterial/fisiología , Determinación de la Presión Sanguínea/instrumentación , Manometría/instrumentación , Sistemas Microelectromecánicos/instrumentación , Análisis por Micromatrices/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA