Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Int J Cardiol ; 140(1): 66-72, 2010 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-19131135

RESUMEN

BACKGROUND: Elevations in troponin T (TnT) occur frequently following percutaneous coronary intervention (PCI) and are associated with an adverse prognosis. The Joint ESC/ACC/AHA/WHF Task Force have released a proposal for a universal definition of myocardial infarction (MI), including diagnostic criteria for PCI associated MI. This is based on a TnT cut-point of more than three times the 99th percentile (0.03 ng/ml), which better reflects the precision of the assay. Our study investigated the incidence and predictive factors of a PCI associated MI, using the revised definition. METHODS: 325 patients were studied following PCI with stenting. TnT was collected at both 8 and 18 h following PCI in patients with either stable or unstable angina and normal baseline TnT levels. Comparison was made of both clinical and procedural characteristics of patients with and without a rise in TnT following intervention, using cut points of 0.01 and 0.03 ng/ml. RESULTS: TnT was elevated > or = 0.03 ng/ml in 27% and > or = 0.01 ng/ml in 39% of patients following PCI. Troponin elevation was significantly more likely in those patients who experienced peri-procedural ischemic symptoms or EKG changes, or in whom abciximab was used. The variables associated with a troponin rise showed a greater difference between TnT positive and negative patients when using 0.03 ng/ml compared to 0.01 ng/ml, suggesting that this may be a better definition of PCI-related MI. CONCLUSIONS: Approximately one-quarter of low risk patients experience a procedural MI according to the revised definition. Rises in troponin were significantly associated with peri-procedural ischemic symptoms and EKG changes, and abciximab use, consistent with this level of TnT reflecting true myocardial necrosis.


Asunto(s)
Angioplastia Coronaria con Balón , Infarto del Miocardio/epidemiología , Troponina T/sangre , Abciximab , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Anticuerpos Monoclonales/uso terapéutico , Electrocardiografía , Humanos , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Incidencia , Masculino , Persona de Mediana Edad , Análisis Multivariante , Inhibidores de Agregación Plaquetaria/uso terapéutico , Pronóstico , Estudios Retrospectivos
3.
Ultrasound Med Biol ; 33(1): 67-73, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17189048

RESUMEN

Optical coherence tomography (OCT) is an optical analog of mechanical intravascular ultrasound (M-IVUS) with much higher spatial resolution. However, no data exist regarding the nonuniform rotational distortion (NURD) with OCT. The aim of the study was to investigate whether OCT generates less NURD relative to M-IVUS. A coronary artery phantom model was constructed with a rubber ring (3.68 mm in diameter), located at the distal end of the phantom. This model was also composed of eight equally spaced steel wires and an additional marker-wire. Two types of vascular phantoms were used, mild curve (90 degrees ) and acute curve (near 180 degrees ). Subsequent M-IVUS (n = 6) and OCT (n = 6) imaging was performed. Eight angles between eight wires, except the marker-wire, were measured from each image. These angles, measured with M-IVUS and OCT, were compared with those of high-resolution optical photography as a gold standard. The average in angle differences was significantly smaller in OCT compared with M-IVUS in the mild curve model (3.2 +/- 1.0 degrees vs, 6.9 +/- 2.1 degrees , p < 0.01). Compared with the latter model, the average in angle differences was exaggerated in the acute curve model with M-IVUS (9.1 +/- 0.9 degrees vs. 6.9 +/- 2.1 degrees , p < 0.05) but not with OCT (3.5 +/- 0.8 degrees vs. 3.2 +/- 1.0 degrees , p= not significant). OCT generates significantly less NURD compared with M-IVUS, especially in tortuous situation.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Ultrasonografía Intervencional/métodos , Artefactos , Cateterismo , Diseño de Equipo , Humanos , Fantasmas de Imagen , Rotación , Tomografía de Coherencia Óptica/instrumentación , Ultrasonografía Intervencional/instrumentación
4.
Circulation ; 114(1 Suppl): I435-40, 2006 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-16820615

RESUMEN

BACKGROUND: The use of saphenous vein grafts (SVG) in coronary artery bypass surgery is established but little is known of SVG remodeling during the first year in vivo. METHODS AND RESULTS: The feasibility of measuring total vessel diameter (lumen plus wall), lumen diameter, and wall thickness by a novel computed tomography (CT) method was established in phantom model tubes (r=0.98 for lumen diameter and r=0.98 for wall thickness) and in an initial clinical study of 14 patients correlating CT and intravascular ultrasound measurements of SVG (r=0.88 for total vessel diameter, r=0.85 for lumen diameter and r=0.89 for wall thickness). In a separate group of 42 patients (aged 66+/-10 years; 36 male, 6 female) undergoing coronary artery bypass grafting, SVG total vessel diameter, lumen diameter, and wall thickness were determined prospectively with multi-slice CT angiography at 1 and 12 months postoperatively. Mean total vessel diameter decreased from 5.95+/-0.83 mm to 5.39+/-0.87 mm, P<0.001 (range, -39% to +8% change). Twenty-six patients (62%) had a decrease of SVG vessel diameter (negative remodeling) >5%. Mean lumen diameter decreased from 3.69+/-0.66 mm to 3.36+/-0.68 mm, P<0.001, (range, -40 to +11% change). Surprisingly, mean wall thickness decreased from 1.14+/-0.27 mm to 1.01+/-0.21 mm (P<0.001; range, -48 to +33% change). CONCLUSIONS: Lumen loss in SVG between postoperative months 1 and 12 is predominantly caused by negative remodeling of the whole vessel rather than to changes in wall thickness. Therapies targeting negative remodeling may be required for optimal maintenance of SVG lumen in the first postoperative year.


Asunto(s)
Puente de Arteria Coronaria/métodos , Reestenosis Coronaria/etiología , Oclusión de Injerto Vascular/etiología , Vena Safena/trasplante , Antagonistas Adrenérgicos beta/farmacología , Anciano , Estudios de Cohortes , Puente de Arteria Coronaria/estadística & datos numéricos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/patología , Reestenosis Coronaria/fisiopatología , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/epidemiología , Oclusión de Injerto Vascular/patología , Oclusión de Injerto Vascular/fisiopatología , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Metoprolol/farmacología , Persona de Mediana Edad , Fantasmas de Imagen , Periodo Posoperatorio , Vena Safena/diagnóstico por imagen , Vena Safena/patología , Método Simple Ciego , Tomografía Computarizada por Rayos X , Trasplante Heterólogo , Ultrasonografía Intervencional
6.
J Am Soc Echocardiogr ; 19(3): 347-53, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16500500

RESUMEN

BACKGROUND: Acute pulmonary thromboembolism (PTE) can be associated with right ventricular (RV) dysfunction. The relative importance of individual echocardiographic parameters, including those suggesting interdependence between right and left heart chambers, in predicting thromboembolic burden in elderly patients with acute PTE is unknown. METHODS: We retrospectively studied the transthoracic echocardiograms of 63 elderly patients (age 71 +/- 16 years) with acute PTE, and assessed which individual echocardiographic parameters identified more than 30% pulmonary artery obstruction on the basis of quantitative ventilation/perfusion pulmonary scintigraphy. RESULTS: RV hypokinesis (visual grade 0-3, P = .02), and the quantitative parameters RV end-systolic area (P = .005) and RV ejection area (P = .01) were associated with more extensive pulmonary artery obstruction. Although right atrial end-systolic area and RV end-diastolic area did not correlate with extent of PTE, the ratio of RV:left ventricular end-diastolic area (P = .003), and ratio of right:left atrial end-systolic area (P = .004), were strongly associated with the extent of pulmonary artery obstruction. These transthoracic echocardiographic parameters were independent of clinical variables such as prior chronic lung disease, congestive cardiac failure, or prior PTE. CONCLUSION: RV systolic dysfunction, RV end-systolic dilatation, right:left atrial end-systolic area ratio, and RV:left ventricular end-diastolic area ratio correlate with extent of PTE in the elderly.


Asunto(s)
Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Embolia Pulmonar/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Anciano , Femenino , Humanos , Masculino , Embolia Pulmonar/complicaciones , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Estadística como Asunto , Disfunción Ventricular Derecha/etiología
7.
Radiology ; 235(2): 415-22, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15858083

RESUMEN

PURPOSE: To investigate prospectively the relative accuracy of computed tomographic (CT) angiography, calcium scoring (CS), and both methods combined in demonstrating coronary artery stenoses by using conventional angiography as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board Human Research Ethics Committee, and all patients completed written informed consent. Fifty patients (40 men, 10 women) aged 62 years +/- 11 (+/- standard deviation) who were suspected of having coronary artery disease underwent both conventional coronary angiography and multisection coronary CT angiography with CS. Sensitivity and specificity of CS, CT angiography, and both methods combined in demonstrating luminal stenosis greater than or equal to 50% were determined for each arterial segment, coronary vessel, and patient. Receiver operating characteristic (ROC) curves were generated for CS prediction of significant stenosis, and the Mann-Whitney U test was used for comparison of CS between groups. RESULTS: When used with segment-specific electrocardiographic phase reconstructions, CT angiography demonstrated stenosed segments with 79% sensitivity and 95% specificity. Mean calcium score was greater in segments, vessels, and patients with stenoses than in segments, vessels, and patients without stenoses (P < .001 for all); nine (16%) of 56 stenosed segments, however, had a calcium score of 0. The patient calcium score correlated strongly with the number of stenosed arteries (Spearman rho = 0.75, P < .001). CS was more accurate in demonstrating stenosis in patients than in segments (areas under ROC curve were 0.88 and 0.74, respectively). CT angiography, however, was more accurate than CS in demonstrating stenosis in patients, vessels, and segments. The sensitivity and specificity of CS varied according to the threshold used, but when the calcium score cutoff (ie, >150) matched the specificity of CT angiography (95%), the sensitivity of CS in demonstrating stenosed segments was 29% (compared with 79% for CT angiography). Combining CT angiography with CS (at threshold of 400) improved the sensitivity of CT angiography (from 93% to 100%) in demonstrating significant coronary disease in patients, without a loss of specificity (85%); this finding, however, was not statistically significant. CONCLUSION: CT angiography is more accurate than CS in demonstrating coronary stenoses. A patient calcium score of greater than or equal to 400, however, can be used to potentially identify patients with significant coronary stenoses not detected at CT angiography.


Asunto(s)
Calcinosis/diagnóstico por imagen , Calcio/análisis , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Tomografía Computarizada Espiral/estadística & datos numéricos , Adulto , Anciano , Algoritmos , Interpretación Estadística de Datos , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Valores de Referencia , Riesgo , Sensibilidad y Especificidad
8.
Am J Cardiol ; 94(9): 1214-6, 2004 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-15518629

RESUMEN

We present a series of 9 adults in 2 families with isolated noncompaction of the ventricular myocardium involving the left ventricular apex. Three of these patients had been previously misdiagnosed as having dilated cardiomyopathy, apical hypertrophic cardiomyopathy, or apical mural thrombus. Phenotypic variation was observed with gradation of severity of noncompaction and left ventricular systolic dysfunction between first-degree relatives.


Asunto(s)
Miocardio/patología , Adolescente , Adulto , Anciano , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/genética , Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/genética , Cardiomiopatía Hipertrófica/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/genética , Enfermedad de la Arteria Coronaria/fisiopatología , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/genética , Trombosis Coronaria/fisiopatología , Diagnóstico Diferencial , Ecocardiografía Doppler en Color , Electrocardiografía Ambulatoria , Salud de la Familia , Femenino , Predisposición Genética a la Enfermedad/genética , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/genética , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad , Linaje , Volumen Sistólico/genética , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA