Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Sci Technol ; 58(5): 2271-2281, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38270974

RESUMEN

To mitigate methane emission from urban natural gas distribution systems, it is crucial to understand local leak rates and occurrence rates. To explore urban methane emissions in cities outside the U.S., where significant emissions were found previously, mobile measurements were performed in 12 cities across eight countries. The surveyed cities range from medium size, like Groningen, NL, to large size, like Toronto, CA, and London, UK. Furthermore, this survey spanned across European regions from Barcelona, ES, to Bucharest, RO. The joint analysis of all data allows us to focus on general emission behavior for cities with different infrastructure and environmental conditions. We find that all cities have a spectrum of small, medium, and large methane sources in their domain. The emission rates found follow a heavy-tailed distribution, and the top 10% of emitters account for 60-80% of total emissions, which implies that strategic repair planning could help reduce emissions quickly. Furthermore, we compare our findings with inventory estimates for urban natural gas-related methane emissions from this sector in Europe. While cities with larger reported emissions were found to generally also have larger observed emissions, we find clear discrepancies between observation-based and inventory-based emission estimates for our 12 cities.


Asunto(s)
Contaminantes Atmosféricos , Gas Natural , Ciudades , Gas Natural/análisis , Metano/análisis , Contaminantes Atmosféricos/análisis , Londres
2.
Sci Rep ; 7(1): 4854, 2017 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-28687748

RESUMEN

A thorough understanding of methane sources is necessary to accomplish methane reduction targets. Urban environments, where a large variety of methane sources coexist, are one of the most complex areas to investigate. Methane sources are characterised by specific δ13C-CH4 signatures, so high precision stable isotope analysis of atmospheric methane can be used to give a better understanding of urban sources and their partition in a source mix. Diurnal measurements of methane and carbon dioxide mole fraction, and isotopic values at King's College London, enabled assessment of the isotopic signal of the source mix in central London. Surveys with a mobile measurement system in the London region were also carried out for detection of methane plumes at near ground level, in order to evaluate the spatial allocation of sources suggested by the inventories. The measured isotopic signal in central London (-45.7 ±0.5‰) was more than 2‰ higher than the isotopic value calculated using emission inventories and updated δ13C-CH4 signatures. Besides, during the mobile surveys, many gas leaks were identified that are not included in the inventories. This suggests that a revision of the source distribution given by the emission inventories is needed.

3.
Sci Rep ; 6: 25661, 2016 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-27210416

RESUMEN

Atmospheric CO at Egham in SE England has shown a marked and progressive decline since 1997, following adoption of strict controls on emissions. The Egham site is uniquely positioned to allow both assessment and comparison of 'clean Atlantic background' air and CO-enriched air downwind from the London conurbation. The decline is strongest (approximately 50 ppb per year) in the 1997-2003 period but continues post 2003. A 'local CO increment' can be identified as the residual after subtraction of contemporary background Atlantic CO mixing ratios from measured values at Egham. This increment, which is primarily from regional sources (during anticyclonic or northerly winds) or from the European continent (with easterly air mass origins), has significant seasonality, but overall has declined steadily since 1997. On many days of the year CO measured at Egham is now not far above Atlantic background levels measured at Mace Head (Ireland). The results are consistent with MOPITT satellite observations and 'bottom-up' inventory results. Comparison with urban and regional background CO mixing ratios in Hong Kong demonstrates the importance of regional, as opposed to local reduction of CO emission. The Egham record implies that controls on emissions subsequent to legislation have been extremely successful in the UK.

4.
J Geophys Res Atmos ; 121(23): 14257-14270, 2016 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-31413935

RESUMEN

A stratified air mass enriched in methane (CH4) was sampled at ~600 m to ~2000 m altitude, between the north coast of Norway and Svalbard as part of the Methane in the Arctic: Measurements and Modelling campaign on board the UK's BAe-146-301 Atmospheric Research Aircraft. The approach used here, which combines interpretation of multiple tracers with transport modeling, enables better understanding of the emission sources that contribute to the background mixing ratios of CH4 in the Arctic. Importantly, it allows constraints to be placed on the location and isotopic bulk signature of the emission source(s). Measurements of δ13C in CH4 in whole air samples taken while traversing the air mass identified that the source(s) had a strongly depleted bulk δ13C CH4 isotopic signature of -70 (±2.1)‰. Combined Numerical Atmospheric-dispersion Modeling Environment and inventory analysis indicates that the air mass was recently in the planetary boundary layer over northwest Russia and the Barents Sea, with the likely dominant source of methane being from wetlands in that region.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA