The study compared the marginal accuracy of premade and cast abutments. Premade titanium, stainless steel, and gold abutments formed the control groups. Plastic abutments were cast in nickel-chromium, cobalt-chromium and grade IV titanium. The abutment/implant interface was analyzed. Analysis of variance and Duncan's multiple range test revealed no significant difference in mean marginal microgap between premade gold and titanium abutments and between premade stainless steel and cast titanium abutments. Statistically significant differences (P < .001) were found among all other groups.


Asunto(s)
Pilares Dentales , Aleaciones Dentales/química , Adaptación Marginal Dental , Diseño de Prótesis Dental , Óxido de Aluminio/química , Aleaciones de Cromo/química , Revestimiento para Colado Dental/química , Grabado Dental/métodos , Diseño de Implante Dental-Pilar , Aleaciones de Oro/química , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Ensayo de Materiales , Fotograbar/métodos , Acero Inoxidable/química , Propiedades de Superficie , Titanio/química , Torque