Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Med Internet Res ; 26: e58278, 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39302714

RESUMEN

BACKGROUND: International Classification of Diseases codes are widely used to describe diagnosis information, but manual coding relies heavily on human interpretation, which can be expensive, time consuming, and prone to errors. With the transition from the International Classification of Diseases, Ninth Revision, to the International Classification of Diseases, Tenth Revision (ICD-10), the coding process has become more complex, highlighting the need for automated approaches to enhance coding efficiency and accuracy. Inaccurate coding can result in substantial financial losses for hospitals, and a precise assessment of outcomes generated by a natural language processing (NLP)-driven autocoding system thus assumes a critical role in safeguarding the accuracy of the Taiwan diagnosis related groups (Tw-DRGs). OBJECTIVE: This study aims to evaluate the feasibility of applying an International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM), autocoding system that can automatically determine diagnoses and codes based on free-text discharge summaries to facilitate the assessment of Tw-DRGs, specifically principal diagnosis and major diagnostic categories (MDCs). METHODS: By using the patient discharge summaries from Kaohsiung Medical University Chung-Ho Memorial Hospital (KMUCHH) from April 2019 to December 2020 as a reference data set we developed artificial intelligence (AI)-assisted ICD-10-CM coding systems based on deep learning models. We constructed a web-based user interface for the AI-assisted coding system and deployed the system to the workflow of the certified coding specialists (CCSs) of KMUCHH. The data used for the assessment of Tw-DRGs were manually curated by a CCS with the principal diagnosis and MDC was determined from discharge summaries collected at KMUCHH from February 2023 to April 2023. RESULTS: Both the reference data set and real hospital data were used to assess performance in determining ICD-10-CM coding, principal diagnosis, and MDC for Tw-DRGs. Among all methods, the GPT-2 (OpenAI)-based model achieved the highest F1-score, 0.667 (F1-score 0.851 for the top 50 codes), on the KMUCHH test set and a slightly lower F1-score, 0.621, in real hospital data. Cohen κ evaluation for the agreement of MDC between the models and the CCS revealed that the overall average κ value for GPT-2 (κ=0.714) was approximately 12.2 percentage points higher than that of the hierarchy attention network (κ=0.592). GPT-2 demonstrated superior agreement with the CCS across 6 categories of MDC, with an average κ value of approximately 0.869 (SD 0.033), underscoring the effectiveness of the developed AI-assisted coding system in supporting the work of CCSs. CONCLUSIONS: An NLP-driven AI-assisted coding system can assist CCSs in ICD-10-CM coding by offering coding references via a user interface, demonstrating the potential to reduce the manual workload and expedite Tw-DRG assessment. Consistency in performance affirmed the effectiveness of the system in supporting CCSs in ICD-10-CM coding and the judgment of Tw-DRGs.

2.
Chem Commun (Camb) ; 54(81): 11495-11498, 2018 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-30259019

RESUMEN

We report a step-saving new access to D-π-D-π-D type oligoaryls through one-pot sequential C-H (hetero)arylations. Conventionally, these oligomers were prepared by Stille or Suzuki coupling reactions that required prefunctionalization steps. The facilely synthesized linear oligomers were fabricated in perovskite-based solar devices as efficient hole transporters, exhibiting a power conversion efficiency of up to 15.4%.

3.
Chem Asian J ; 13(11): 1510-1515, 2018 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-29603676

RESUMEN

In contrast to the traditional multistep synthesis, we demonstrate herein a two-step synthesis shortcut to triphenylamine-based hole-transporting materials (HTMs) through sequential direct C-H arylations. These hole-transporting molecules are fabricated in perovskite-based solar cells (PSCs) that exhibit promising efficiencies up to 17.69 %, which is comparable to PSCs utilizing commercially available 2,2',7,7'-tetrakis[N,N-di(4-methoxyphenyl)amino]-9,9'-spirobifluorene (spiro-OMeTAD) as the HTM. This is the first report describing the use of step-saving C-H activations/arylations in the facile synthesis of small-molecule HTMs for perovskite solar cells.

4.
BMC Anesthesiol ; 14: 75, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25210501

RESUMEN

BACKGROUND: The abdominal insufflation and surgical positioning in the laparoscopic surgery have been reported to result in an increase of airway pressure. However, associated effects on changes of endotracheal tube cuff pressure are not well established. METHODS: 70 patients undergoing elective laparoscopic colorectal tumor resection (head-down position, n = 38) and laparoscopic cholecystecomy (head-up position, n = 32) were enrolled and were compared to 15 patients undergoing elective open abdominal surgery. Changes of cuff and airway pressures before and after abdominal insufflation in supine position and after head-down or head-up positioning were analysed and compared. RESULTS: There was no significant cuff and airway pressure changes during the first fifteen minutes in open abdominal surgery. After insufflation, the cuff pressure increased from 26 ± 3 to 32 ± 6 and 27 ± 3 to 33 ± 5 cmH2O in patients receiving laparoscopic cholecystecomy and laparoscopic colorectal tumor resection respectively (both p < 0.001). The head-down tilt further increased cuff pressure from 33 ± 5 to 35 ± 5 cmH2O (p < 0.001). There six patients undergoing colorectal tumor resection (18.8%) and eight patients undergoing cholecystecomy (21.1%) had a total increase of cuff pressure more than 10 cm H2O (18.8%). There was no significant correlation between increase of cuff pressure and either the patient's body mass index or the common range of intra-abdominal pressure (10-15 mmHg) used in laparoscopic surgery. CONCLUSIONS: An increase of endotracheal tube cuff pressure may occur during laparoscopic surgery especially in the head-down position.


Asunto(s)
Anestesia por Inhalación/métodos , Intubación Intratraqueal/métodos , Laparoscopía/métodos , Posicionamiento del Paciente , Adulto , Anciano , Resistencia de las Vías Respiratorias , Índice de Masa Corporal , Femenino , Cabeza , Inclinación de Cabeza , Humanos , Masculino , Persona de Mediana Edad , Presión , Estudios Prospectivos
5.
BMC Med Educ ; 14: 168, 2014 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-25123826

RESUMEN

BACKGROUND: Medical students often learn the skills necessary to perform a central venous catheterization in the operating room after simulator training. We examined the performance of central venous catheterization by medical students from the logbooks during their rotation in department of anesthesiology. METHODS: From the logbooks of medical students rotating in our department between January 2011 and June 2012, we obtained the kind and the number of central venous catheterization students had done, the results of the procedures whether they were success or failed, the reasons of the failures, complications, and the student self-reported confidence and satisfaction of their performance. RESULTS: There were 93 medical students performed 875 central venous catheterizations with landmark guidance on patients in the operating theater, and the mean number of catheterizations performed per student was 9.4 ± 2.0, with a success rate of 67.3%. Adjusted for age, sex, body mass index, surgical category, ASA score and insertion site, the odds of successful catherization improved with cumulative practice (odds ratio 1.10 per additional central venous catheterization performed; 95% confidence interval 1.05-1.15). The major challenge students encountered during the procedure was the difficulty of finding the central veins, which led to 185 catheterizations failed. The complication rate of central venous catheterization by the students was 7.8%, while the most common complication was puncture of artery. The satisfaction and confidence of students regarding their performance increased with each additional procedure and decreased significantly if failure or complications had occurred. CONCLUSION: A student logbook is a useful tool for recording the actual procedural performance of students. From the logbooks, we could see the students' performance, challenges, satisfaction and confidence of central venous catheterization were improved through cumulative clinical practice of the procedure.


Asunto(s)
Cateterismo Venoso Central , Educación Médica , Adulto , Cateterismo Venoso Central/efectos adversos , Competencia Clínica , Curriculum , Femenino , Humanos , Masculino , Maniquíes , Quirófanos , Estudios Retrospectivos , Taiwán , Adulto Joven
6.
J Orthop Surg Res ; 9: 42, 2014 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-24885387

RESUMEN

BACKGROUND: Surgical managements are recommended for unstable distal clavicle fractures because of a high incidence of nonunion. A variety of methods have been previously reported, but there is no current consensus regarding which method is the most suitable. METHODS: Between December 2004 and August 2010, we treated 68 patients with Neer type IIB distal clavicle fractures using single coracoclavicular suture fixation with Mersilene tape (M group) or clavicular hook plate (H group). Sixty-eight patients were followed at least 24 months (mean, 37.9 months). We retrospectively compared the functional outcome, parameters, and perioperative course of the two treatments. Statistical analysis was performed with independent sample t test and chi-square test. RESULTS: The M group presented significantly less operation time (P = 0.005) and intra-operative blood loss (P = 0.010) than the H group. The mean University of California at Los Angeles (UCLA) shoulder rating scale, Oxford shoulder score, VAS scale, and satisfaction score revealed no significant difference between the M group and the H group. The M group had better range of motion in the operated shoulder during forward flexion and abduction at 3 and 6 months postoperatively. However, the range of motion at 1 and 2 years after operation revealed almost the same results. Two acromial osteolysis and one acromial fracture were noted in the H group and one superficial wound infection and one frozen shoulder in the M group during follow-up. Finally, there was no significant difference in the complication rate between the two groups, and all fractures achieved union clinically at final follow-up. CONCLUSIONS: Both single coracoclavicular suture fixation and clavicular hook plate offered effective treatment in acute unstable distal clavicle fractures. However, single coracoclavicular suture fixation with Mersilene tape provided early recovery of shoulder motion and avoided further morbidity of the acromion.


Asunto(s)
Placas Óseas/normas , Clavícula/lesiones , Clavícula/cirugía , Fijación Interna de Fracturas/normas , Fracturas Óseas/cirugía , Adolescente , Adulto , Anciano , Clavícula/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
8.
Acta Anaesthesiol Taiwan ; 50(2): 49-53, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22769857

RESUMEN

BACKGROUND/PURPOSE: Weak opioid combined with acetaminophen (APAP) has been proven to provide better analgesic efficacy and cause fewer complications than either drug alone. However, there are questions about whether different opioids, tramadol and propoxyphene, provide similar efficacy or safety. Thus, we investigated Ultracet (37.5 mg tramadol/325 mg APAP) and Depain-X (65 mg propoxyphene/650 mg APAP). The primary aims of this study were to compare the analgesic efficacy and adverse effects of single-dose oral Ultracet versus Depain-X in acute postoperative pain. MATERIALS AND METHODS: This was a randomized, open-label, active-controlled parallel study on patients with postsurgical pain. Sixty patients who sustained moderate postsurgical pain (visual analog scale(3)3 cm) after undergoing implantation of venous access were randomized to two groups to receive either Ultracetor Depain-X for postoperative analgesia. Assessment items included pain intensity and pain relief ratings at the first 4 hours, and adverse events. RESULTS: There were initially 107 patients who were enrolled in this trial, but up to 45 (42.1%) of them were withdrawn during the study. In these 62 patients who complied with treatment (Ultracet: Depain-X = 29: 33), pain relief scale indicated that Ultracet could provide a better analgesic effect than Depain-X provided at 1 hour (p < 0.05). At 4 hours, the pain score in the Ultracet group was significantly lower than that in the Depain-X group (p < 0.05). Adverse events, such as drowsiness, dizziness, and skin itching did not differ in both groups. CONCLUSION: Among patients with mild to moderate postoperative wound pain, single-dose Ultracet can provide slightly better analgesic efficacy than Depain-X in terms of onset and duration. Depain-X is no longer marketed in Europe, America, Taiwan and other countries, therefore, Ultracet can serve as a good substitute for treating postoperative pain.


Asunto(s)
Acetaminofén/administración & dosificación , Analgésicos/uso terapéutico , Dextropropoxifeno/uso terapéutico , Dolor Postoperatorio/tratamiento farmacológico , Tramadol/administración & dosificación , Acetaminofén/efectos adversos , Acetaminofén/uso terapéutico , Adulto , Anciano , Dextropropoxifeno/efectos adversos , Combinación de Medicamentos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tramadol/efectos adversos
9.
Cardiol J ; 19(1): 89-91, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22298175

RESUMEN

With its unique en face view, real time three-dimensional transesophageal echocardiography has been reported to be more precise than conventional two-dimensional studies in evaluating mitral regurgitation etiology, and can locate diseased segments correctly. We present a case with severe mitral regurgitation due to anterior mitral leaflet perforation. Intraoperative real time three-dimensional transesophageal echocardiography demonstrated its value in diagnosis and surgical planning for this perforation, which had not been identified preoperatively. This technique should be applied more widely for dedicated mitral valve assessment in clinical practice.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Endocarditis/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Endocarditis/microbiología , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/microbiología , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/microbiología , Insuficiencia de la Válvula Mitral/cirugía , Pericardio/trasplante , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Streptococcus/aislamiento & purificación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA