Magn Reson Med ; 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39301770

RESUMEN

PURPOSE: Chemical exchange saturation transfer (CEST) measurements at ultra-high field (UHF) suffer from strong saturation inhomogeneity. Retrospective correction of this inhomogeneity is possible to some extent, but requires a time-consuming repetition of the measurement. Here, we propose a calibration-free parallel transmit (pTx)-based saturation scheme that homogenizes the saturation over the imaging volume, which we call PUlse design for Saturation Homogeneity utilizing Universal Pulses (PUSHUP). THEORY: Magnetization transfer effects depend on the saturation B 1 rms $$ {\mathrm{B}}_1^{\mathrm{rms}} $$ . PUSHUP homogenizes the saturation B 1 rms $$ {\mathrm{B}}_1^{\mathrm{rms}} $$ by using multiple saturation pulses with alternating B 1 $$ {\mathrm{B}}_1 $$ -shims. Using a database of B 1 $$ {\mathrm{B}}_1 $$ maps, universal pulses are calculated that remove the necessity of time-consuming, subject-based pulse calculation during the measurement. METHODS: PUSHUP was combined with a whole-brain three-dimensional-echo planar imaging (3D-EPI) readout. Two PUSHUP saturation modules were calculated by either applying whole-brain or cerebellum masks to the database maps. The saturation homogeneity and the group mean CEST amplitudes were calculated for different B 1 $$ {\mathrm{B}}_1 $$ -correction methods and were compared to circular polarized (CP) saturation in five healthy volunteers using an eight-channel transmit coil at 7 Tesla. RESULTS: In contrast to CP saturation, where accurate CEST maps were impossible to obtain in the cerebellum, even with extensive B 1 $$ {\mathrm{B}}_1 $$ -correction, PUSHUP CEST maps were artifact-free throughout the whole brain. A 1-point retrospective B 1 $$ {\mathrm{B}}_1 $$ -correction, that does not need repeated measurements, sufficiently removed the effect of residual saturation inhomogeneity. CONCLUSION: The presented method allows for homogeneous whole-brain CEST imaging at 7 Tesla without the need of a repetition-based B 1 $$ {\mathrm{B}}_1 $$ -correction or online pulse calculation. With the fast 3D-EPI readout, whole-brain CEST imaging with 45 saturation offsets is possible at 1.6 mm resolution in under 4 min.

2.
Magn Reson Med ; 92(5): 2037-2050, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39054786

RESUMEN

PURPOSE: T 2 $$ {}_2 $$ -weighted turbo-spin-echo (TSE) sequences are a fundamental technique in brain imaging but suffer from field inhomogeneities at ultra-high fields. Several methods have been proposed to mitigate the problem, but were limited so far to nonselective three-dimensional (3D) measurements, making short acquisitions difficult to achieve when targeting very high resolution images, or needed additional calibration procedures, thus complicating their application. METHODS: Slab-selective excitation pulses were designed for flexible placement utilizing the concept of k T $$ {}_T $$ -spokes. Phase-coherent refocusing universal pulses were subsequently optimized with the Gradient Ascent Pulse Engineering algorithm and tested in vivo for improved signal homogeneity. RESULTS: Implemented within a 3D variable flip angle TSE sequence, these pulses led to a signal-to-noise ratio (SNR) improvement ranging from 10% to 30% compared to a two-dimensional (2D) T2w TSE sequence employing B 1 + $$ {\mathrm{B}}_1^{+} $$ -shimmed pulses. B 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneities could be mitigated and artifacts from B 0 $$ {\mathrm{B}}_0 $$ deviations reduced. The concept of universal pulses was successfully applied. CONCLUSION: We present a pulse design method which provides a set of calibration-free universal pulses (UPs) for slab-selective excitation and phase-coherent refocusing in slab-selective TSE sequences.


Asunto(s)
Algoritmos , Encéfalo , Imagenología Tridimensional , Imagen por Resonancia Magnética , Relación Señal-Ruido , Humanos , Encéfalo/diagnóstico por imagen , Calibración , Fantasmas de Imagen , Ondas de Radio , Procesamiento de Imagen Asistido por Computador/métodos
3.
Magn Reson Med ; 88(6): 2564-2572, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35942989

RESUMEN

PURPOSE: We present a time-efficient water-selective, parallel transmit RF excitation pulse design for ultra-high field applications. METHODS: The proposed pulse design method achieves flip angle homogenization at ultra-high fields by employing spatially nonselective k T $$ {\mathrm{k}}_T $$ -points pulses. In order to introduce water-selection, the concept of binomial pulses is applied. Due to the composite nature of k T $$ {\mathrm{k}}_T $$ -points, the pulse can be split into multiple binomial subpulse blocks shorter than half the precession period of fat, that are played out successively. Additional fat precession turns, that would otherwise impair the spectral response, can thus be avoided. Bloch simulations of the proposed interleaved binomial k T $$ {\mathrm{k}}_T $$ -points pulses were carried out and compared in terms of duration, homogeneity, fat suppression and pulse energy. For validation, in vivo MP-RAGE and 3D-EPI data were acquired. RESULTS: Simulation results show that interleaved binomial k T $$ {\mathrm{k}}_T $$ -points pulses achieve shorter total pulse durations, improved flip angle homogeneity and more robust fat suppression compared to available methods. Interleaved binomial k T $$ {\mathrm{k}}_T $$ -points can be customized by changing the number of k T $$ {\mathrm{k}}_T $$ -points, the subpulse duration and the order of the binomial pulse. Using shorter subpulses, the number of k T $$ {\mathrm{k}}_T $$ -points can be increased and hence better homogeneity is achieved, while still maintaining short total pulse durations. Flip angle homogenization and fat suppression of interleaved binomial k T $$ {\mathrm{k}}_T $$ -points pulses is demonstrated in vivo at 7T, confirming Bloch simulation results. CONCLUSION: In this work, we present a time efficient and robust parallel transmission technique for nonselective water excitation with simultaneous flip angle homogenization at ultra-high field.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Agua , Algoritmos , Encéfalo , Simulación por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen