Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1043649

RESUMEN

Background@#In the Rivaroxaban Once-daily oral direct factor Xa inhibition Compared with vitamin K antagonism for prevention of stroke and Embolism Trial in Atrial Fibrillation (ROCKET AF) trial, rivaroxaban 20 mg was the on-label dose, and the dose-reduction criterion for rivaroxaban was a creatinine clearance of 65 years of age with or without renal impairment. @*Results@#A total of 1,093 patients (mean age, 72.8 ± 5.8 years; 686 [62.9%] men) were included in the analysis, with 493 patients allocated to the HDRR group and 598 patients allocated to the LDRR group. A total of 765 patients received 15 mg of rivaroxaban (203 in the HDRR group and 562 in the LDRR group). There were no significant differences in the incidence rates of major bleeding (adjusted hazard ratio [HR], 0.64; 95% confidential interval [CI], 0.21–1.93), stroke (adjusted HR, 3.21; 95% CI, 0.54–19.03), and composite outcomes (adjusted HR, 1.13;95% CI, 0.47–2.69) between the HDRR and LDRR groups. @*Conclusion@#This study revealed the safety and effectiveness of either dose regimen of rivaroxaban in an Asian population for stroke prevention of AF. Considerable numbers of patients are receiving LDRR therapy in real-world practice in Asia. Both regimens were safe and effective for these patients.

2.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1001185

RESUMEN

Background@#The objective of this study was to evaluate the efficacy and safety of totally thoracoscopic ablation (TTA) in patients with recurrent atrial fibrillation (AF) after radiofrequency catheter ablation (RFCA). @*Methods@#From February 2012 to May 2020, 460 patients who underwent TTA were classified into two groups: CA (presence of RFCA history, n = 74) and nCA groups (absence of RFCA history, n = 386). Inverse probability of treatment weighting (IPTW) analyses were used to adjust for confounders. The primary endpoint was freedom from the composite of AF, typical atrial flutter, atypical atrial flutter and any atrial tachyarrhythmia, lasting more than 30 seconds during the follow-up. All patients were followed up at 3, 6, and 12 months via electrocardiogram and 24-hour Holter monitoring. @*Results@#Bilateral pulmonary vein isolation (PVI) was conducted in all patients and the conduction block tests were confirmed. In the CA group, difficult PVI occasionally occurred due to structural changes, such as pericardial adhesion and fibrosis of the pulmonary venous structure, caused by a previous catheter ablation. Early complications such as stroke and pacemaker insertion were not different between the two groups. The normal sinus rhythm was maintained in 70.1% (317/460) patients after a median follow-up period of 38.1 months.The IPTW-weighted Kaplan-Meier curves revealed that freedom from AF events at 5 years was 68.4% (95% confidence interval, 62.8–74.5) in the nCA group and 31.2% (95% confidence interval, 16.9–57.5) in the CA group (P < 0.001). In IPTW-weighted Cox regression, preoperative left atrial diameter, persistent or long-standing AF, the presence of congestive heart failure and catheter ablation history were associated with AF events. @*Conclusion@#Patients in the CA group showed a higher recurrence rate of AF than those in the nCA group, while TTA was safely performed in both the groups.

3.
Journal of Stroke ; : 199-213, 2023.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1001582

RESUMEN

Atrial fibrillation (AF) is a leading cause of cardioembolic stroke, which is often fatal or disabling. Prevention of stroke is crucial in AF management, and anticoagulation with non-vitamin K oral anticoagulants (NOACs) is the mainstay of AF management for stroke prevention. Because NOAC prescriptions have been surging worldwide, the development of acute ischemic stroke in patients with AF who receive NOAC treatment is an increasingly important issue in clinical practice. Moreover, these patients show a high risk of recurrence, with more than a 50% higher risk, than do patients with AF and no prior anticoagulation therapy. Careful evaluation is mandatory to determine possible causes of ischemic stroke during NOAC therapy. Differentiation of AF-unrelated stroke and demonstration of combined cardiac disease/systemic coagulopathy are important in these patients and may provide improved results in their treatment. In addition, ensuring appropriate dosing and good adherence to NOAC treatment is important. Cardioembolism, despite sufficient anticoagulation and no other causes, is the most common and challenging complication because switching to anticoagulants or adding antiplatelets to the treatment regimen does not reduce the risk of recurrent stroke, and there are no guidelines for this specific situation. This review article aimed to present the most updated data on the prevalence, causes, and secondary prevention strategies, specifically focusing on non-pharmacological approaches, together with relevant cases of AF in patients who developed ischemic stroke on NOAC therapy.

4.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1003032

RESUMEN

Background/Aims@#Atrial fibrillation (AF) is a common arrhythmia and is associated with cardiovascular morbidity and mortality. It is important to identify and control the modifiable risk factors of AF. We aimed to examine the association of exercise capacity with the risk of incident AF within 3 years in healthy subjects. @*Methods@#We evaluated asymptomatic adults who had undergone more than two consecutive health checkups. We included subjects who exhibited normal sinus rhythm on the first health examination and who developed AF on the second or subsequent health examinations. Subjects who underwent cardiopulmonary exercise testing within 3 years before the diagnosis of AF were examined. @*Results@#The study population in the analyses included 428 cases (mean age 58.4 ± 7.6 yr, male 95.6%). There were significant differences in maximal systolic blood pressure (SBP; case 169.4 ± 24.2 vs. control 173.9 ± 22.3 mmHg), peak VO2 (29.5 ± 5.4 vs. 30.4 ± 4.8 mL/kg per minute), and maximal metabolic equivalents (METs; 8.5 ± 1.6 vs. 8.7 ± 1.4) between the two groups. In the multivariable logistic models, adjusted odds ratios were 0.99 for maximal SBP (95% confidence interval [CI] 0.98–0.99), 0.97 for peak VO2 (95% CI 0.95–0.99), and 0.91 for maximal METs (95% CI 0.83–0.98). @*Conclusions@#We demonstrated that poorer exercise capacity was associated with the development of AF in a healthy population. A prospective, systematic trial is necessary to confirm that appropriate exercise training will be beneficial in preventing the development of AF in such patients.

5.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1040812

RESUMEN

Background@#In patients with non-paroxysmal AF (atrial fibrillation), various ablation strategies have been attempted to target non-pulmonary vein (PV) foci or to achieve substrate modification beyond pulmonary vein isolation. The efficacy of empirical ablation of the SVC, one of the most common non-PV foci, is unclear. The aim of this study was to investigate the efficacy and safety of additional superior vena cava (SVC) isolation in patients with non-parox‑ ysmal AF undergoing thoracoscopic surgical ablation. @*Methods@#/results A total of 191 patients with persistent or long-standing persistent AF was enrolled. All patients underwent total thoracoscopic surgical ablation for AF, and half of them also received empirical SVC isolation. We compared the atrial tachyarrhythmia (ATa)-free survival rate and procedure-related complications in the two groups of patients. The 3-year ATa-free survival rate was 53% in the SVC isolation group and 52% in the no-SVC isolation group (p = 0.644). There were no differences between the two groups with respect to AF type or LA size. Procedure-related complications occurred in 12 patients (6%). Pacemakers were implanted only in three patients from the SVC isolation group. The only factor influencing recurrence of ATa was LA diameter. @*Conclusions@#Empirical SVC isolation during thoracoscopic ablation for persistent AF did not improve patient outcomes.

6.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-925064

RESUMEN

As the indications for catheter-based electrophysiologic procedures become more diverse and complex, accurate assessment of the anatomy of intracardiac structure has become essential for the optimal clinical outcome. Since intracardiac echocardiography (ICE) was first introduced in 1980, it has become an integral part of various electro‑ physiologic procedures enabling accurate visualization of cardiac structures and continuous monitoring of catheter position, with integration of real-time images and electroanatomic mapping. Catheter ablation for outflow tract ventricular arrhythmias (OTVAs) has been actively performed in symptomatic patients. However, the anatomic com‑ plexity of OT serves as the biggest obstacle to obtain the optimal results. In OTVAs, ICE has played an invaluable role in precisely defining the anatomic shell of OT beyond fluoroscopy and in guiding catheter manipulation in relation to critical structures like the conduction system and coronary arteries. This review article provides detailed information on comprehensive application of ICE for catheter ablation of OTVAs.

7.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-966960

RESUMEN

Background@#An exponential rise in clinical demand for cardiac implantable electronic device (CIED) therapy is observed all over the world due to the rapidly expanding lifespan. Accordingly, appropriate lead management including lead extraction is becoming increasingly essential components for the comprehensive care of patients with various CIEDs.Main body: With a high success rate and a low complication rate, transvenous lead extraction (TLE) has now been established as first-line therapy for lead extraction. However, TLE is often challenging when there are heavily calcified fibrous adhesions between leads and cardiovascular structures. Recently, rotational mechanical dilator (RMD) sheaths were introduced to resolve this issue and facilitate TLE procedure. There are two types of commercially available RMD sheaths, Evolution ® systems and TightRail™. Thorough knowledge of the proper use of the RMD devices is essential to increase success rate and to reduce complications of TLE. In the present review, mechanical features, various tech‑ niques, and clinical data of RMD sheaths will be described. @*Conclusion@#According to recent advancement of device technology, the clinical outcomes of TLE using the RMD sheaths are continuously improving. However, as the RMD sheath is a potentially aggressive tool, special care should be taken when used in patients with longer lead ages.

8.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-915459

RESUMEN

Background@#The efficacy of catheter ablation for persistent atrial fibrillation (AF) remains suboptimal. A hybrid approach of catheter ablation combined with totally thoracoscopic surgical ablation can improve outcomes. In this study, we evaluated the efficacy of the early staged hybrid procedure in hospital stay after totally thoracoscopic ablation compared to the stand-alone totally thoracoscopic ablation. @*Methods@#Patients who underwent totally thoracoscopic ablation from February 2012 to December 2018 were included in this study. We compared the outcomes of the totally thoracoscopic ablation only group versus the early staged hybrid procedure group. The primary outcome was recurrence of atrial tachyarrhythmia after three months of blanking period. The secondary outcome was repeated unplanned additional electrophysiology study and catheter ablation due to atrial tachyarrhythmia recurrence. @*Results@#A total of 306 patients (mean age, 56.8 ± 8.5 years; 278 [90.8%] males) was included in the study, with 81 patients in the early staged hybrid group and 225 patients in the standalone totally thoracoscopic ablation only group. The mean follow-up duration was 30.0 months. Overall arrhythmia-free survival showed no significant difference between the two groups (log-rank P = 0.402). There was no significant difference in the rate of repeat procedure between the two groups (log-rank = 0.11). @*Conclusion@#The early staged hybrid procedure after thoracoscopic ablation could not improve the outcome of recurrence of atrial tachyarrhythmia. The second stage of electrophysiology study could be deferred to patients with recurrence of atrial tachyarrhythmia during follow up after totally thoracoscopic ablation.

9.
Korean Circulation Journal ; : 430-431, 2020.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-816674

RESUMEN

No abstract available.


Asunto(s)
Miocardio
10.
Korean Circulation Journal ; : 998-1009, 2020.
Artículo | WPRIM (Pacífico Occidental) | ID: wpr-833063

RESUMEN

Background and Objectives@#Pacemaker (PM) implantation is a well-accepted treatment option for patients with paroxysmal atrial fibrillation (AF) and related tachycardiabradycardia syndrome (TBS). Data on the long-term clinical outcomes after radiofrequency catheter ablation (RFCA) or PM implantation are sparse. @*Methods@#The medical records of 217 patients with TBS were retrospectively assessed.Outcomes in patients who underwent RFCA (n=108, 49.8%) were compared to those with PM implantation (n=109, 50.2%). The clinical outcomes were sinus rhythm maintenance, conversion to persistent AF, additional procedure or crossover, and the composite of cardiovascular hospitalization and death. @*Results@#During the follow-up period (mean 3.5±2.0 years), the RFCA group, compared to the PM group, showed better sinus rhythm maintenance (adjusted hazard ratio [aHR], 0.27;95% confidence interval [CI], 0.15–0.46; p=0.002) and less progression to persistent AF (aHR, 0.20; 95% CI, 0.06–0.63; p=0.006). Additional procedure or crossover did not differ significantly between the groups (aHR, 2.07; 95% CI, 0.71–6.06; p=0.185 and aHR, 0.69; 95% CI, 10.8–2.67; p=0.590, respectively). Most RFCA patients (92.6%) did not require pacemaker implantation during long term follow-up period (>3.5 years). The composite endpoint of cardiovascular rehospitalization and death was not significantly different between the groups (aHR, 0.92; 95% CI, 0.50–1.66; p=0.769).Background and Objectives: Pacemaker (PM) implantation is a well-accepted treatment option for patients with paroxysmal atrial fibrillation (AF) and related tachycardiabradycardia syndrome (TBS). Data on the long-term clinical outcomes after radiofrequency catheter ablation (RFCA) or PM implantation are sparse. @*Methods@#The medical records of 217 patients with TBS were retrospectively assessed.Outcomes in patients who underwent RFCA (n=108, 49.8%) were compared to those with PM implantation (n=109, 50.2%). The clinical outcomes were sinus rhythm maintenance, conversion to persistent AF, additional procedure or crossover, and the composite of cardiovascular hospitalization and death. @*Results@#During the follow-up period (mean 3.5±2.0 years), the RFCA group, compared to the PM group, showed better sinus rhythm maintenance (adjusted hazard ratio [aHR], 0.27;95% confidence interval [CI], 0.15–0.46; p=0.002) and less progression to persistent AF (aHR, 0.20; 95% CI, 0.06–0.63; p=0.006). Additional procedure or crossover did not differ significantly between the groups (aHR, 2.07; 95% CI, 0.71–6.06; p=0.185 and aHR, 0.69; 95% CI, 10.8–2.67; p=0.590, respectively). Most RFCA patients (92.6%) did not require pacemaker implantation during long term follow-up period (>3.5 years). The composite endpoint of cardiovascular rehospitalization and death was not significantly different between the groups (aHR, 0.92; 95% CI, 0.50–1.66; p=0.769). @*Conclusions@#RFCA is an effective alternative to PM implantation in patients with TBS.In these patients, successful RF ablation of AF is related to a higher rate of sinus rhythm maintenance compared to PM implantation, and the composite outcome of cardiovascular rehospitalization and death is similar.

11.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-765018

RESUMEN

BACKGROUND: Although device-based optimization has been developed to overcome the limitations of conventional optimization methods in cardiac resynchronization therapy (CRT), few real-world data supports the results of clinical trials that showed the efficacy of automatic optimization algorithms. We investigated whether CRT using the adaptive CRT algorithm is comparable to non-adaptive biventricular (BiV) pacing optimized with electrocardiogram or echocardiography-based methods. METHODS: Consecutive 155 CRT patients were categorized into 3 groups according to the optimization methods: non-adaptive BiV (n = 129), adaptive BiV (n = 11), and adaptive left ventricular (LV) pacing (n = 15) groups. Additionally, a subgroup of patients (n = 59) with normal PR interval and left bundle branch block (LBBB) was selected from the non-adaptive BiV group. The primary outcomes included cardiac death, heart transplantation, LV assist device implantation, and heart failure admission. Secondary outcomes were electromechanical reverse remodeling and responder rates at 6 months after CRT. RESULTS: During a median 27.5-month follow-up, there was no significant difference in primary outcomes among the 3 groups. However, there was a trend toward better outcomes in the adaptive LV group compared to the other groups. In a more rigorous comparisons among the patients with normal PR interval and LBBB, similar patterns were still observed. CONCLUSION: In our first Asian-Pacific real-world data, automated dynamic CRT optimization showed comparable efficacy to conventional methods regarding clinical outcomes and electromechanical remodeling.


Asunto(s)
Humanos , Bloqueo de Rama , Terapia de Resincronización Cardíaca , Muerte , Electrocardiografía , Estudios de Seguimiento , Insuficiencia Cardíaca , Trasplante de Corazón , Virus de la Inmunodeficiencia Bovina
12.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-740052

RESUMEN

Treatment of ventricular arrhythmias (VA) usually involves managing the underlying cardiac conditions that cause the arrhythmia. However, managing the underlying disease is often challenging, and catheter ablation, or treatment targeting the VA itself might be required in a few patients. In this article, we explored evidence and recommendations regarding the treatment of VA in patients with structural heart disease focusing on the utilization of catheter ablation in these patients. The administration of optimal medical therapy, insertion of an implantable cardioverter-defibrillator, or resynchronization therapy improves survival in patients with left ventricular dysfunction. The role of catheter ablation in preventing sudden cardiac death remains uncertain in this population. In patients with coronary artery disease, reversing myocardial ischemia via revascularization is important in managing VA. Catheter ablation is recommended in patients with recurrent ventricular tachycardia in a setting of ischemic heart disease. In patients with non-ischemic cardiomyopathies such as dilated cardiomyopathy or hypertrophic cardiomyopathy, catheter ablation may be considered for those presenting with drug-refractory ventricular tachycardia.


Asunto(s)
Humanos , Arritmias Cardíacas , Cardiomiopatías , Cardiomiopatía Dilatada , Cardiomiopatía Hipertrófica , Ablación por Catéter , Catéteres , Enfermedad de la Arteria Coronaria , Muerte Súbita Cardíaca , Desfibriladores Implantables , Cardiopatías , Isquemia Miocárdica , Taquicardia Ventricular , Disfunción Ventricular Izquierda
13.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-740053

RESUMEN

The recommendations outlined constitute the first clinical practice guidelines of the Korean Heart Rhythm Society regarding catheter ablation of ventricular arrhythmias (VA). This is a guideline PART 2, which includes VA in the structurally normal heart, inherited primary arrhythmia syndromes, VA related to congenital heart disease, as well as VA and sudden cardiac death observed in specific populations. In the structurally normal heart, treatment is guided by the occurrence of symptoms or the frequency of arrhythmias that cause ventricular dysfunction over time. Catheter ablation can be recommended in patients in whom anti-arrhythmic medications are ineffective. The sites of origin of arrhythmic activity are known to be the outflow tract, fascicles, papillary muscle, or the annulus. Specific cardiac channelopathies include congenital long QT and Brugada syndrome. This guideline discusses the diagnostic criteria, risk stratification, and treatment of these syndromes. We have included recommendations for adult congenital heart disease. Moreover, we have discussed the management of VA occurring in specific populations such as in patients with psychiatric and neurological disorders, pregnant patients, those with obstructive sleep apnea or drug-related pro-arrhythmias, athletes, and elderly patients.


Asunto(s)
Adulto , Anciano , Humanos , Arritmias Cardíacas , Atletas , Síndrome de Brugada , Ablación por Catéter , Catéteres , Canalopatías , Muerte Súbita Cardíaca , Corazón , Cardiopatías Congénitas , Enfermedades del Sistema Nervioso , Músculos Papilares , Apnea Obstructiva del Sueño , Disfunción Ventricular
14.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-740054

RESUMEN

Ventricular arrhythmias (VA) are a major cause of sudden cardiac death (SCD) in patients with known heart disease. Risk assessment and effective prevention of SCD are key issues in these patients. Implantable cardioverter defibrillator (ICD) insertion effectively treats sustained VA and reduces mortality in patients at high risk of SCD. Appropriate anti-arrhythmic drugs and catheter ablation reduce the VA burden and the occurrence of ICD shocks. In this guideline, authors have described the general examination and medical treatment of patients with VA. Medications and catheter ablation are also used as acute phase therapy for sustained VA.


Asunto(s)
Humanos , Arritmias Cardíacas , Ablación por Catéter , Catéteres , Muerte Súbita Cardíaca , Desfibriladores , Cardiopatías , Mortalidad , Medición de Riesgo , Choque
15.
Yonsei Medical Journal ; : 703-709, 2017.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-21752

RESUMEN

PURPOSE: This study aimed to determine whether upgrade cardiac resynchronization therapy (CRT) shows better outcomes than de novo CRT. To do so, we compared the efficacy of CRT between de novo and upgrade groups, focusing particularly on the effect of upgrade CRT on patients with pacing-induced cardiomyopathy (PiCM). MATERIALS AND METHODS: PiCM was defined as new-onset dilated cardiomyopathy following pacemaker implantation in patients with baseline normal ejection fraction ≥50%. Electro-mechanical reverse remodeling and clinical outcomes were compared among the de novo (n=62), PiCM upgrade (n=7), and non-PiCM upgrade (n=8) CRT groups. RESULTS: The PiCM upgrade group showed significantly greater electro-mechanical reverse remodeling than the de novo CRT or non-PiCM upgrade groups at 6-month follow-up. The rate of super-responders was significantly higher in the PiCM upgrade group than the other CRT groups. The group factor of the PiCM upgrade was identified as an independent predictor of super-responder in multivariate analysis (odds ratio 10.4, 95% confidential interval 1.08–99.4, p=0.043). During the median follow-up of 15.8 months, the PiCM upgrade group showed the lowest rate of composite clinical outcomes, including cardiac death, heart transplantation, and heart failure-related rehospitalization (p=0.059). CONCLUSION: The upgrade CRT for PiCM patients showed better performance in terms of electro-mechanical reverse remodeling than de novo implantation or upgrade CRT in non-PiCM patients.


Asunto(s)
Humanos , Terapia de Resincronización Cardíaca , Cardiomiopatías , Cardiomiopatía Dilatada , Muerte , Grupos Focales , Estudios de Seguimiento , Corazón , Trasplante de Corazón , Análisis Multivariante , Remodelación Ventricular
16.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-105551

RESUMEN

Double tachycardia is defined as the coexistence of supraventricular tachycardia (SVT) and ventricular tachycardia (VT). In clinical practice, incidentally encountered double tachycardia is difficult to diagnose during electrophysiology study without prior documentation of both tachycardias. SVT can be confused with VT because SVT sometimes show an aberrant conduction depending on heart rate. In the present case, a patient with Wolff-Parkinson-White syndrome exhibited atrioventricular reentrant tachycardia (AVRT) via a concealed bypass tract and idiopathic left ventricular tachycardia (ILVT), which were difficult to discriminate because of their similar cycle length and interrelationship.


Asunto(s)
Humanos , Electrofisiología , Frecuencia Cardíaca , Taquicardia , Taquicardia Supraventricular , Taquicardia Ventricular , Síndrome de Wolff-Parkinson-White
17.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-14440

RESUMEN

Riata defibrillator leads were recalled due to a high failure rate. This study measured the incidence of externalized conductor (EC) and electrical dysfunction (ED) and sought to determine the predictors of ED with Riata defibrillator leads. We enrolled patients who received Riata® or Riata® ST silicone defibrillator leads at our center between January 2003 and December 2010. The presence of EC was evaluated with chest radiography. The incidence rates were measured at 5 years after lead implantation. We also investigated the rates of ED and other clinical events during the follow-up period. A total of 44 patients were analyzed. The total cumulative incidence of EC was 27.3%. During the median dwell time (80 months), the incidence of ED was 22.7%. Patients with ED were younger (46.5 vs. 56.5 years, P = 0.018) and had a higher prevalence of cardiomyopathy than those without ED (60.0% vs. 20.6%, P = 0.043). ECs were most frequently detected in patients who underwent X-ray analysis 3–5 years after lead implantation (44.4%). In contrast, ED had a bimodal incidence pattern, with peaks at 5 years (7.0%) and 9 years (5.3%). There was no difference in ED-free survival rate between patients with and without EC (P = 0.628). Given the delayed occurrence of EC and ED after implantation of Riata defibrillator leads, long-term close monitoring is critically important.


Asunto(s)
Humanos , Cardiomiopatías , Desfibriladores , Desfibriladores Implantables , Falla de Equipo , Seguridad de Equipos , Estudios de Seguimiento , Incidencia , Prevalencia , Radiografía , Silicio , Siliconas , Tasa de Supervivencia , Tórax
18.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-222396

RESUMEN

BACKGROUND AND OBJECTIVES: The safety and efficacy of implantable cardioverter-defibrillator (ICD) for Korean is unclear. We investigated the clinical characteristics and outcomes of Korean patients undergoing ICD for primary or secondary prevention. MATERIALS AND METHODS: From October 1999 to December 2016, 396 cases (365 patients) of ICD implantation were performed: Baseline characteristics, procedural findings, and clinical outcome data were collected retrospectively from our ICD registry. The primary outcome was composite of cardiac death, appropriate shock or antitachycardia pacing. RESULTS: Among 365 patients, 91 patients (25.9%) had ICD for primary prevention and 274 patients (75.1%) were for secondary prevention (51.2±17.10 years, male was 80.8%). The median follow-up period was 3.1 years (interquartile range: 1.6–6.0 days). The most prevalent etiology was dilated cardiomyopathy (46.2%) in the primary prevention and idiopathic ventricular tachycardia or fibrillation (24.4%) in the secondary prevention. The primary outcome was noted in 28.6% of the primary prevention and 33.2% of the secondary prevention (P=0.44). The rate of cardiac death was 2.2% in the primary prevention and 1.8% in the secondary prevention (P=1.00). The hospitalization due to heart failure was higher in the primary prevention compared with the secondary prevention (23.1% versus 13.5%, P=0.03). ICD therapy occurred in 134 patients (36.7%). Among them, 60 patients (44.8% of ICD therapy) experienced inappropriate shock. The most common cause of inappropriate shock was atrial fibrillation of flutter (AF/AFL). CONCLUSION: The clinical efficacy and safety of ICD in Korean is consistent with the data from Western countries.


Asunto(s)
Humanos , Masculino , Fibrilación Atrial , Cardiomiopatía Dilatada , Muerte , Desfibriladores Implantables , Estudios de Seguimiento , Insuficiencia Cardíaca , Hospitalización , Prevención Primaria , Estudios Retrospectivos , Prevención Secundaria , Choque , Taquicardia Ventricular , Resultado del Tratamiento
19.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-111252

RESUMEN

BACKGROUND: The absence of atrial contraction (AC) after the maze procedure has been reported to cause subsequent annular dilatation and to increase the risk of embolic stroke. We hypothesized that the lack of AC could increase the risk of permanent pacemaker (PPM) implantation in patients undergoing the maze procedure. METHODS: In 376 consecutive patients who had undergone a cryo-maze procedure and combined valve operation, recovery of AC was assessed at baseline and at immediate (≤2 weeks), early (≤1 year, 4.6±3.8 months), and late (>1 year, 3.5±1.1 years) postoperative stages. RESULTS: With a median follow-up of 53 months, 10 patients underwent PPM implantation. Seven PPM implants were for sinus node dysfunction (pauses of 9.6±2.4 seconds), one was for marked sinus bradycardia, and two were for advanced/complete atrioventricular block. The median (interquartile range) time to PPM implantation was 13.8 (0.5–68.2) months. Our time-varying covariate Cox models showed that the absence of AC was a risk factor for PPM implantation (hazard ratio, 11.92; 95% confidence interval, 2.52 to 56.45; p=0.002). CONCLUSION: The absence of AC may be associated with a subsequent risk of PPM implantation.


Asunto(s)
Humanos , Fibrilación Atrial , Bloqueo Atrioventricular , Bradicardia , Criocirugía , Dilatación , Estudios de Seguimiento , Modelos de Riesgos Proporcionales , Factores de Riesgo , Síndrome del Seno Enfermo , Accidente Cerebrovascular
20.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-122519

RESUMEN

The clinical significance of prolonged PR interval has not been evaluated in patients with frequent premature atrial contractions (PACs). We investigated whether prolonged PR interval could predict new occurrence of atrial fibrillation (AF) in patients with frequent PACs. We retrospectively analyzed 684 patients with frequent PACs (> 100 PACs/day) who performed repeated 24-hour Holter monitoring. Prolonged PR interval was defined as longer than 200 msec. Among 684 patients, 626 patients had normal PR intervals (group A) and 58 patients had prolonged PR intervals (group B). After a mean follow-up of 59.3 months, 14 patients (24.1%) in group B developed AF compared to 50 patients (8.0%) in group A (P < 0.001). Cox regression analysis showed that prolonged PR interval (hazard ratio [HR], 1.950; 95% CI, 1.029-3.698; P = 0.041), age (HR, 1.033; 95% CI, 1.006-1.060; P = 0.015), and left atrial (LA) dimension (HR, 1.061; 95% CI, 1.012-1.112; P = 0.015) were associated with AF occurrence. Prolonged PR interval, advanced age, and enlarged LA dimension are independent risk factors of AF occurrence in patients with frequent PACs.


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Edad , Área Bajo la Curva , Fibrilación Atrial/diagnóstico , Complejos Atriales Prematuros/complicaciones , Electrocardiografía Ambulatoria , Estudios de Seguimiento , Corazón/diagnóstico por imagen , Estimación de Kaplan-Meier , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Curva ROC , Estudios Retrospectivos , Factores de Riesgo , Factores Sexuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA