J Cancer Res Ther ; 13(6): 1050-1052, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29237975

RESUMEN

Dose escalation improves local control in carcinoma prostate, but rectal toxicity remains a concern. Various techniques have been there to reduce the dose to the rectum. Mobility of the prostate results in a necessary expansion of the target volume. We describe a new intrarectal fixative, developed in-house with transrectal ultrasonography through the fixative itself for localization of the organ by reporting a case with early carcinoma prostate. Concerns of rectal toxicity limit dose escalation in the treatment of prostate cancer. Intra- and interfraction prostate motion is a concern in dose conformity techniques. The intrarectal fixative system developed in-house physically separates the prostate and rectum during radiation treatment. Thus, both intra- and inter-fractional movement of the organ are addressed, therefore planning target volume expansion can be kept minimal.


Asunto(s)
Carcinoma/radioterapia , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Anciano , Carcinoma/diagnóstico por imagen , Carcinoma/patología , Fraccionamiento de la Dosis de Radiación , Humanos , Masculino , Próstata/diagnóstico por imagen , Próstata/patología , Próstata/efectos de la radiación , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Recto/diagnóstico por imagen , Recto/patología , Recto/efectos de la radiación , Tomografía Computarizada por Rayos X
2.
J Med Phys ; 38(3): 120-4, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24049318

RESUMEN

Trigeminal neuralgia (TN) is treated in CyberKnife (Accuray Inc, Sunnyvale, USA) with the 5 mm collimator whose dosimetric inaccuracy is higher than the other available collimators. The 7.5 mm collimator which is having less dosimetric uncertainty can be an alternative for 5 mm collimator provided the dose distribution with 7.5 mm collimator is acceptable. Aim of this study is to analyze the role of 7.5 mm collimator in CyberKnife treatment plans of TN. The treatment plans with 5 mm collimators were re-optimized with 7.5 mm collimator and a bi-collimator system (5 mm and 7.5 mm). The treatment plans were compared for target coverage, brainstem doses, and the dose to normal tissues. The target and brainstem doses were comparable. However, the conformity indices were 2.31 ± 0.52, 2.40 ± 0.87 and 2.82 ± 0.51 for 5 mm, bi-collimator (5mm and 7.5 mm), 7.5 mm collimator plans respectively. This shows the level of dose spillage in 7.5 mm collimator plans. The 6 Gy dose volumes in 7.5 mm plans were 1.53 and 1.34 times higher than the 5 mm plan and the bi-collimator plans respectively. The treatment time parameters were lesser for 7.5 mm collimators. Since, the normal tissue dose is pretty high in 7.5 mm collimator plans, the use of it in TN plans can be ruled out though the treatment time is lesser for these 7.5 mm collimator plans.

3.
J Med Phys ; 38(3): 132-8, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24049320

RESUMEN

The objective of this study is to check the feasibility of in vivo rectal dose measurement in intensity-modulated radiotherapy (IMRT) and CyberKnife treatments for carcinoma prostate. An in-house pelvis phantom made with bee's wax was used in this study. Two cylindrical bone equivalent materials were used to simulate the femur. Target and other critical structures associated with carcinoma prostate were delineated on the treatment planning images by the radiation oncologist. IMRT treatment plan was generated in Oncentra Master Plan treatment planning system and CyberKnife treatment plan was generated in Multiplan treatment planning system. Dose measurements were carried out in phantom and in patient using Gafchromic EBT3 films. RIT software was used to analyze the dose measured by EBT3 films. The measured doses using EBT3 films were compared with the TPS-calculated dose along the anterior rectal wall at multiple points. From the in-phantom measurements, it is observed that the difference between calculated and measured dose was mostly within 5%, except for a few measurement points. The difference between calculated and measured dose in the in-patient measurements was higher than 5% in regions which were away from the target. Gafchromic EBT3 film is a suitable detector for in vivo rectal dose measurements as it offers the possibility of analyzing the dose at multiple points. In addition, the method of extending this in vivo rectal dose measurement technique as a tool for patient-specific quality assurance check is also analyzed.

4.
Med Dosim ; 38(4): 385-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23809693

RESUMEN

The present study is to analyze the CyberKnife hypofractionated dose distribution of localized prostate cancer in terms of high-dose rate (HDR) brachytherapy equivalent doses to assess the degree of HDR brachytherapy resemblance of CyberKnife dose distribution. Thirteen randomly selected localized prostate cancer cases treated using CyberKnife with a dose regimen of 36.25Gy in 5 fractions were considered. HDR equivalent doses were calculated for 30Gy in 3 fractions of HDR brachytherapy regimen. The D5% of the target in the CyberKnife hypofractionation was 41.57 ± 2.41Gy. The corresponding HDR fractionation (3 fractions) equivalent dose was 32.81 ± 1.86Gy. The mean HDR fractionation equivalent dose, D98%, was 27.93 ± 0.84Gy. The V100% of the prostate target was 95.57% ± 3.47%. The V100% of the bladder and the rectum were 717.16 and 79.6mm(3), respectively. Analysis of the HDR equivalent dose of CyberKnife dose distribution indicates a comparable resemblance to HDR dose distribution in the peripheral target doses (D98% to D80%) reported in the literature. However, there is a substantial difference observed in the core high-dose regions especially in D10% and D5%. The dose fall-off within the OAR is also superior in reported HDR dose distribution than the HDR equivalent doses of CyberKnife.


Asunto(s)
Neoplasias de la Próstata/cirugía , Radiocirugia , Braquiterapia , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Dosis de Radiación , Estudios Retrospectivos
5.
J Radiosurg SBRT ; 2(2): 85-98, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-29296347

RESUMEN

Multiplan treatment planning system, used with Cyberknife system, provides the option of using either the ray tracing algorithm or the Monte Carlo algorithm for the final dose calculation. In order to compare and validate the dose calculations of these algorithms, especially in a heterogeneous medium, a lung phantom study was carried out. Validation has been done with thermoluminiscent dosimetry (TLD) using lithium fluoride rods for the point doses and film dosimetry using EBT2 films for the dose distribution. In the point dose measurements, an agreement of 100.1+2.6 % (1 SD) is observed with the Monte Carlo dose calculation, whereas it is only 91.2+ 3.2% (1 SD) with the ray tracing calculation. On subjecting the dose distributions from irradiated EBT2 films for validation of Monte Carlo calculation MC , over 96% of the pixels pass the gamma criteria of 3mm and 3cGy.On analyzing the dose profiles from EBT2 films and the corresponding profiles from the plan calculated using the Monte Carlo algorithm, it is seen that the maximum distance-to-agreement values are within the 3mm criteria set, whereas the maximum values are as high as 8 mm when compared with plan calculated using ray tracing algorithm. The results of the actual measurements are more consistent with the dose calculation by the Monte Carlo algorithm.

6.
J Med Phys ; 38(4): 173-7, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24672151

RESUMEN

Gafchromic films are used as dosimeter for in vivo and in phantom dose measurements. The dose response of Gafchromic EBT2 film under single and repeated exposure conditions is compared in this study to analyze the usability of Gafchromic EBT2 films in cumulative dose measurements. The post-irradiation change in response of the film is studied for up to 4 days after irradiation. The effect of repeated exposure to scanner light on the response of the film is also studied. To check usability of Gafchromic EBT2 films in cumulative dose measurements, three EBT2 films were exposed to a daily fraction dose of 100 cGy, 150 cGy and 200 cGy, respectively, for 4 days. The dose response of the films exposed to cumulative irradiation was compared with the dose measured from films exposed to the same dose but in a single exposure. It is observed that the post-irradiation darkening of the film does not saturate and continue to take place even 4 days after irradiation. The dose measured from the EBT2 films after 4 days from irradiation was around 2% higher than the dose measured from the same films at 24 hours post-irradiation. It was also observed that the repeated exposure to scanner light does not produce any significant change in the film response. The dose response of films exposed to cumulative irradiation agrees with the dose response of films exposed to the same dose in a single irradiation with less than 3% difference. Gafchromic EBT2 films can be used to measure the cumulative dose delivered over multiple fractions, when the delivered dose is uniform across the film.

7.
J Cancer Res Ther ; 8(3): 367-72, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23174716

RESUMEN

AIM: The Monte Carlo dose calculation algorithm yields accurate dose distributions in heterogeneous media and interfaces. The Monte Carlo calculation algorithm provided in the Multiplan Cyberknife treatment planning system (Accuray, Sunnyvale, CA, USA) has five different dose-smoothing algorithms in it. As the principle of smoothing of these algorithms is different, they can produce a disparity in the final dose distribution. The aim of the present study is to analyze the influence of these Monte Carlo smoothing algorithms in the final dose distribution of cyberknife treatment plans. MATERIALS AND METHODS: An anthropomorphic lung phantom with a tumor mimicking ball target was taken for this study. The basic optimization was performed with the Ray tracing algorithm. The Monte Carlo calculations were introduced with each smoothing algorithm on the basic plan and the plans were compared. RESULTS: The Monte Carlo doses were found to be lesser than the Ray tracing doses. The dose conformity index was above 4 for all the smoothing algorithms, while it was only 1.19 for Ray tracing. The least coverage of 6.34 was obtained for a weighted average algorithm. The deviation between the V100% values of different smoothing algorithms was higher than the deviation in V80%. CONCLUSION: The deviations between the smoothing algorithms are higher in the high-dose regions, including the prescribing isodose, than the low-dose regions of the target, as well as in the organs at risk (OAR).


Asunto(s)
Neoplasias Pulmonares/radioterapia , Método de Montecarlo , Fantasmas de Imagen , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Algoritmos , Humanos , Pulmón/patología , Pulmón/efectos de la radiación , Dosificación Radioterapéutica
8.
J Med Phys ; 37(3): 124-8, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22973078

RESUMEN

CyberKnife radiosurgery treatment of Trigeminal neuralgia (TN) is performed as a non-invasive image guided procedure. The prescription dose for TN is very high. The brainstem is the adjacent critical organ at risk (OAR) which is prone to receive the very high target dose of TN. The present study is to analyze the dose distribution inside the tiny trigeminal nerve target and also to analyze the dose fall off in the brain stem. Seven TN cases treated between November 2010 and January 2012 were taken for this study retrospectively. The treatment plans were analyzed for target dose conformity, homogeneity and dose coverage. In the brainstem the volume doses D(1%), D(2%) were taken for analyzing the higher doses in the brain stem. The dose fall off was analyzed in terms of D(5%) and D(10%). The mean value of maximum dose within the trigeminal nerve target was 73.5±2.1Gy (P=0.0007) and the minimum dose was 50.0±4.1Gy (P=0.1315). The mean conformity index was 2.19 and the probable reason could be the smallest CyberKnife collimator of 5mm used in the treatment plan. The mean D(1%), of the brainstem was 10.5± 2.1Gy (P=0.5316) and the mean value of the maximum point dose within the brainstem was 35.6±3.8Gy. This shows the degree of dose fall off within the brainstem. Though the results of the present study are showing superior sparing of brain stem and reasonable of target coverage, it is necessary to execute the treatment plan with greater accuracy in CyberKnife as the immobilization is noninvasive and frameless.

9.
J Med Phys ; 37(2): 90-6, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22557798

RESUMEN

As the α/ß value of prostate is very small and lower than the surrounding critical organs, hypofractionated radiotherapy became a vital mode of treatment of prostate cancer. Cyberknife (Accuray Inc., Sunnyvale, CA, USA) treatment for localized prostate cancer is performed in hypofractionated dose regimen alone. Effective dose escalation in the hypofractionated regimen can be estimated if the corresponding conventional 2 Gy per fraction equivalent normalized total dose (NTD) distribution is known. The present study aims to analyze the hypofractionated dose distribution of localized prostate cancer in terms of equivalent NTD. Randomly selected 12 localized prostate cases treated in cyberknife with a dose regimen of 36.25 Gy in 5 fractions were considered. The 2 Gy per fraction equivalent NTDs were calculated using the formula derived from the linear quadratic (LQ) model. Dose distributions were analyzed with the corresponding NTDs. The conformity index for the prescribed target dose of 36.25 Gy equivalent to the NTD dose of 90.63 Gy (α/ß = 1.5) or 74.31 Gy (α/ß = 3) was ranging between 1.15 and 1.73 with a mean value of 1.32 ± 0.15. The D5% of the target was 111.41 ± 8.66 Gy for α/ß = 1.5 and 90.15 ± 6.57 Gy for α/ß = 3. Similarly, the D95% was 91.98 ± 3.77 Gy for α/ß = 1.5 and 75.35 ± 2.88 Gy for α/ß = 3. The mean values of bladder and rectal volume receiving the prescribed dose of 36.25 Gy were 0.83 cm3 and 0.086 cm3, respectively. NTD dose analysis shows an escalated dose distribution within the target for low α/ß (1.5 Gy) with reasonable sparing of organs at risk. However, the higher α/ß of prostate (3 Gy) is not encouraging the fact of dose escalation in cyberknife hypofractionated dose regimen of localized prostate cancer.

10.
J Med Phys ; 37(1): 4-7, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22363106

RESUMEN

Dose linearity studies on conventional linear accelerators show a linearity error at low monitor units (MUs). The purpose of this study was to establish the dose linearity and MU stability characteristics of a cyberknife (Accuray Inc., USA) stereotactic radiosurgery system. Measurements were done at a depth of 5 cm in a stereotactic dose verification phantom with a source to surface distance of 75 cm in a Generation 4 (G4) type cyberknife system. All the 12 fixed-type collimators starting from 5 to 60 mm were used for the dose linearity study. The dose linearity was examined in small (1-10), medium (15-100) and large (125-1000) MU ranges. The MU stability test was performed with 60 mm collimator for 10 MU and 20 MU with different combinations. The maximum dose linearity error of -38.8% was observed for 1 MU with 5 mm collimator. Dose linearity error in the small MU range was considerably higher than in the medium and large MU ranges. The maximum error in the medium range was -2.4%. In the large MU range, the linearity error varied between -0.7% and 1.2%. The maximum deviation in the MU stability was -3.03%.

11.
J Med Phys ; 37(4): 214-8, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23293453

RESUMEN

Total body irradiation (TBI) is a special radiotherapy technique, administered prior to bone marrow transplantation. Due to the complex nature of the treatment setup, in vivo dosimetry for TBI is mandatory to ensure proper delivery of the intended radiation dose throughout the body. Lithium fluoride (LiF) TLD-100 chips are used for the TBI in vivo dosimetry. Results obtained from the in vivo dosimetry of 20 patients are analyzed. Results obtained from forehead, abdomen, pelvis, and mediastinum showed a similar pattern with the average measured dose from 96 to 97% of the prescription dose. Extremities and chest received a dose greater than the prescription dose in many instances (more than 20% of measurements). Homogeneous dose delivery to the whole body is checked by calculating the mean dose with standard deviation for each fraction. Reasons for the difference between prescription dose and measured dose for each site are discussed. Dose homogeneity within ±10% is achieved using our in-house TBI protocol.

12.
J Neurooncol ; 106(3): 637-42, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21892741

RESUMEN

A dosimetric comparison of linear accelerator (LA)-based (BrainLAB) and robotic radiosurgery (RS) (CyberKnife) systems for acoustic schwannoma (Acoustic neuroma, AN) was carried out. Seven patients with radiologically confirmed unilateral AN were planned with both an LA-based (BrainLAB) and robotic RS (CyberKnife) system using the same computed tomography (CT) dataset and contours. Gross tumour volume (GTV) was contoured on post-contrast magnetic resonance imaging (MRI) scan [planning target volume (PTV) margin 2 mm]. Planning and calculation were done with appropriate calculation algorithms. The prescribed isodose in both systems was considered adequate to cover at least 95% of the contoured target. Plan evaluations were done by examining the target coverage by the prescribed isodose line, and high- and low-dose volumes. Isodose plans and dose volume histograms generated by the two systems were compared. There was no statistically significant difference between the contoured volumes between the systems. Tumour volumes ranged from 380 to 3,100 mm(3). Dose prescription was 13-15 Gy in single fraction (median prescribed isodose 85%). There were no significant differences in conformity index (CI) (0.53 versus 0.58; P = 0.225), maximum brainstem dose (4.9 versus 4.7 Gy; P = 0.935), 2.5-Gy volume (39.9 versus 52.3 cc; P = 0.238) or 5-Gy volume (11.8 versus 16.8 cc; P = 0.129) between BrainLAB and CyberKnife system plans. There were statistically significant differences in organs at risk (OAR) doses, such as mean cochlear dose (6.9 versus 5.4 Gy; P = 0.001), mean mesial temporal dose (2.6 versus 1.7 Gy; P = 0.07) and high-dose (10 Gy) volume (3.2 versus 5.2 cc; P = 0.017). AN patients planned with the CyberKnife system had superior OAR (cochlea and mesial temporal lobe) sparing compared with those planned with the Linac-based system. Further evaluation of these findings in prospective studies with clinical correlation will provide actual clinical benefit from the dosimetric superiority of CyberKnife.


Asunto(s)
Neuroma Acústico/cirugía , Radiometría/métodos , Radiocirugia/métodos , Robótica , Adulto , Mapeo Encefálico , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Neuroma Acústico/diagnóstico por imagen , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X , Adulto Joven
13.
J Med Phys ; 35(2): 113-9, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20589121

RESUMEN

Radical radiotherapy is one of the options for the management of prostate cancer. In external beam therapy, 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are the options for delivery of increased radiation dose, as vital organs are very close to the prostate and a higher dose to these structures leads to an increased toxicity. In brachytherapy, low dose rate brachytherapy with permanent implant of radioactive seeds and high dose rate brachytherapy (HDR) with remote after loaders are available. A dosimetric analysis has been made on IMRT and HDR brachytherapy plans. Ten cases from each IMRT and HDR brachytherapy have been taken for the study. The analysis includes comparison of conformity and homogeneity indices, D100, D95, D90, D80, D50, D10 and D5 of the target. For the organs at risk (OAR), namely rectum and bladder, V100, V90 and V50 are compared. In HDR brachytherapy, the doses to 1 cc and 0.1 cc of urethra have also been studied. Since a very high dose surrounds the source, the 300% dose volumes in the target and within the catheters are also studied in two plans, to estimate the actual volume of target receiving dose over 300%. This study shows that the prescribed dose covers 93 and 92% of the target volume in IMRT and HDR brachytherapy respectively. HDR brachytherapy delivers a much lesser dose to OAR, compared to the IMRT. For rectum, the V50 in IMRT is 34.0cc whilst it is 7.5cc in HDR brachytherapy. With the graphic optimization tool in HDR brachytherapy planning, the dose to urethra could be kept within 120% of the target dose. Hence it is concluded that HDR brachytherapy may be the choice of treatment for cancer of prostate in the early stage.

14.
J Med Phys ; 32(1): 12-7, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21217913

RESUMEN

Over the past few decades, cones of different diameter (12.5 mm to 40 mm) were used for treatment of intracranial lesions. These give very focused dose delivery to the target with minimum dose to outside normal brain tissues. This study is intended to compare the older method of arc-based stereotactic treatments using cones with the new mini-multileaf collimator (mMLC). Treatment plans are made for various sites of intracranial lesions with the cones and mMLC. In case of nonspherical lesions, more than one isocenter is used to get an optimum dose distribution with cones, while a single isocenter is sufficient with mMLC. Treatment plans are compared for irregular lesions using cones with multiple isocenters and mMLC. It is observed that conformity index and dose heterogeneity are better for mMLC based treatments.

15.
Med Dosim ; 31(4): 273-82, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17134667

RESUMEN

The quantitative dose validation of intensity-modulated radiation therapy (IMRT) plans require 2-dimensional (2D) high-resolution dosimetry systems with uniform response over its sensitive region. The present work deals with clinical use of commercially available self-developing Radio Chromic Film, Gafchromic EBT film, for IMRT dose verification. Dose response curves were generated for the films using a VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak extended dose range 2 (EDR2) films. The EBT film had a linear response between the dose range of 0 to 600 cGy. The dose-related characteristics of the EBT film, such as post irradiation color growth with time, film uniformity, and effect of scanning orientation, were studied. There was up to 8.6% increase in the color density between 2 to 40 hours after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative differences between calculated and measured dose distributions were analyzed using DTA and Gamma index with the tolerance of 3% dose difference and 3-mm distance agreement. The EDR2 films showed consistent results with the calculated dose distributions, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large-field IMRT verification. For IMRT of smaller field sizes (4.5 x 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films.


Asunto(s)
Dosimetría por Película/instrumentación , Radioterapia de Intensidad Modulada/instrumentación , Relación Dosis-Respuesta en la Radiación , Humanos , Dosificación Radioterapéutica
16.
J Med Phys ; 31(2): 78-82, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21206669

RESUMEN

This work was undertaken with the intention of investigating the possibility of clinical use of commercially available self-developing radiochromic film - Gafchromic EBT film - for IMRT dose verification. The dose response curves were generated for the films using VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak EDR2 films. It was found that the EBT film has a linear response between the dose ranges of 0 and 600 cGy. The dose-related characteristics of the EBT film, like post-irradiation color growth with time, film uniformity and effect of scanning orientation, were studied. There is up to 8.6% increase in the color density between 2 and 40 h after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative difference between calculated and measured dose distributions was analyzed using Gamma index with the tolerance of 3% dose difference and 3 mm distance agreement. EDR2 films showed good and consistent results with the calculated dose distribution, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large field IMRT verification. For IMRT of smaller field size (4.5 × 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films.

17.
J Indian Med Assoc ; 93(11): 421-4, 1995 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8775923
18.
Indian J Exp Biol ; 31(3): 291-3, 1993 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8388856

RESUMEN

Carbohydrate rich diet, rice, raggi or tapioca given to individuals of both sexes for 15 days did not alter the glycemic response (after oral glucose loading) as compared to an isocaloric wheat basal back ground diet. However, plasma cholesterol profile was reduced significantly by raggi and tapioca. Raggi reduced total serum cholesterol; low density lipoprotein cholesterol by 9% each, triglycerides by 15% and increased high density lipoprotein cholesterol, showing a significant beneficial effect on plasma cholesterol profile. Lipemic index as introduced in the present study was 121, 57 and 55 for rice, tapioca and raggi respectively when base line value of the isocaloric wheat supplemented back ground diet (control) was taken as 100.


Asunto(s)
Glucemia/metabolismo , Dieta , Lípidos/sangre , Adulto , Carbohidratos de la Dieta/administración & dosificación , Fibras de la Dieta/administración & dosificación , Grano Comestible , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Int J Vitam Nutr Res ; 62(3): 266-8, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1473911

RESUMEN

To assess the true physiological basis of carbohydrate exchange of food, commonly eaten in South India, the "Glycemic Index", defined as the area of the glucose tolerance test, under 3 hr, for each food item, expressed as percentage of the area after taking the same amount of carbohydrate as glucose (75 gms) was studied, in healthy fasting human volunteers. Thirteen articles of food items were fed to groups of 12 to 15 healthy fasting volunteers and their glucose tolerance test values up to 3 hr, were measured. The highest glycemic index values were shown by starchy tubers, Raggi and fleshy fruits, while relatively lower values were obtained for pulses and rice; whole wheat showed the smallest glycemic index.


Asunto(s)
Glucemia/metabolismo , Carbohidratos de la Dieta/metabolismo , Adulto , Femenino , Prueba de Tolerancia a la Glucosa , Humanos , India , Masculino