Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Conserv Dent ; 20(2): 86-90, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28855753

RESUMEN

BACKGROUND: Endodontically treated teeth often lack sufficient support for a permanent restoration. During post space preparation, it is important not to disturb the integrity of the apical seal. AIM: This study compared the effect of immediate versus delayed post space preparation on the apical seal using four different sealers. MATERIALS AND METHODS: One hundred and thirty single rooted teeth were biomechanically prepared and obturated with single cone gutta-percha and 4 sealers: Endoflas FS, AH Plus, Gutta flow and MTA. Teeth were divided randomly into eight groups, post spaces were prepared using Gates Glidden drills immediately for group I, III, IV and VII. For groups II, IV, VI and VIII prepared after storage of the specimens in 100% humidity for one week. The samples were kept in methylene blue dye, centrifuged at 3000 rpm for 3 min sectioned and then measured under stereomicroscope for apical leakage. STATISTICAL ANALYSIS: The data was analysed using one way ANOVA and post hoc Tukey test. RESULTS: All the specimens showed dye leakage, and a statistically significant difference was seen among all the groups (P > 0.05) except Gutta flow. CONCLUSION: Less leakage is seen when post space is prepared immediately.

2.
J Int Oral Health ; 7(9): 31-5, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26435613

RESUMEN

BACKGROUND: The purpose of this study was to compare the shear bond strength of nanocomposite resin to superficial dentin and deep dentin using two different dentin bonding systems. MATERIALS AND METHODS: All teeth were sectioned at various levels (superficial dentin: Dentin within 0.5-1 mm of dentinoenamel junction; deep dentin: Dentin within 0.5 mm of the highest pulp horn) using a Carborundum Disc and embedded in acrylic block of specific size. Selected specimens (60 premolar teeth) were grouped randomly into three groups, the groups were differentiated into superficial dentin, deep dentin, and control group which were further divided into sub Group A and Subgroup B containing 10 teeth each, depending on the bonding agents used. In Subgroup A, Tetric N Bond, and in Subgroup B Single Bond Universal were used. In the control group no bonding agent was used. The specimens were thermocycled for 500 cycles between 5°C and 55°C water bath for 40 s. Finally, the specimens were subjected to shear bond strength study under INSTRON machine (Universal Testing Machine). The maximum shear bond strengths were noted at the time of fracture (de-bonding) of the restorative material. Results were analyzed using ANOVA test, Bonferroni test, and paired t-test. RESULTS: Bond strength values of fifth generation bonding system (Tetric N Bond) showed higher mean shear bond strength compared to seventh generation bonding system (Single Bond Universal). There was a significant fall in bond strength values as one reaches deeper levels of dentin from superficial to deep dentin. CONCLUSION: There was a significant difference between the bond strength of fifth generation bonding system (Tetric N Bond) and seventh generation bonding system (Single Bond Universal). Decrease in the bond strength values is seen for the deeper level of dentin as compared to superficial dentin.

3.
J Int Oral Health ; 7(7): 63-70, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26229373

RESUMEN

BACKGROUND: It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins. MATERIALS AND METHODS: 90 Disks of nanocomposites resin (Filtek Z350 XT) measuring 8 mm in diameter and 2 mm in thickness were fabricated using a custom made silicon mold. Pre-polishing surface roughness (Ra1) of all the 90 samples were measured using a Surface Profilometer. The nano-composite disks were then randomly divided into 3 groups with 30 samples in each group. Group I: CONTROL GROUP: The samples were not subjected to any polishing procedures. Group II: Sof-Lex group: Samples subjected to polishing using different grits of Sof-Lex disks. Group III: Diamond polishing paste group: Samples were subjected with a polishing paste consisting of diamond particles. Following polishing procedures, the surface roughness of all samples were measured again to obtain change in surface roughness due to polishing procedures (Ra2), pre immersion spectrophotometric value (ΔE1) was also recorded for baseline color of the samples. The samples were then divided into subgroups (A, B, C, D, E), by including every first sample in Subgroup A, second in Subgroup B, third in Subgroup C, fourth in Subgroup D, and fifth in Subgroup E. Each was immersed in the respective test solution for 10 min, twice a day for 30 days. Group A - Tea, Group B - Coffee, Group C - Cola, Group D - Turmeric, Group E - Control (artificial saliva). Post immersion profilometric value was recorded to evaluate roughness bought about by the solutions (Ra3) and spectrophotometric value was recorded to evaluate the color change in samples (ΔE2). Results were statistically analyzed using ANOVA. RESULTS: Higher mean roughness (Ra2-Ra1) value was recorded in Sof-Lex, followed by Diamond polishing paste and Control group. Comparison of surface roughness caused due to beverages and food colorant solution showed subgroup C (Coca Cola) increased surface roughness in all groups (Group I, II, III). Subgroup D (Turmeric) had the highest discoloration potential (P < 0001) in all groups, followed by coffee, tea, coca-cola and artificial saliva. Sof-Lex polishing System showed most color stability. CONCLUSION: Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls. One-step polishing system (diamond polishing paste) produces a smoother surface compared to a multi-step system (Sof-Lex polishing disks). Turmeric solution caused maximum staining of the samples, to a visually perceptible level.

4.
J Int Oral Health ; 7(Suppl 1): 43-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26225104

RESUMEN

BACKGROUND: To compare the microtensile bond strength of resin cements to enamel and dentin and to determine the type of bond failure using stereomicroscope. MATERIALS AND METHODS: In this in-vitro study 40 teeth were embedded in acrylic resin and divided into two main groups i.e., Group A for enamel and Group B for dentin. Each group is again subdivided into four subgroups, which are as follows; Subgroup 1 for Calibra resin cement, Subgroup 2 for Paracem, Subgroup 3 for Variolink II and Subgroup 4 for Rely X ARC. These resin cements were applied on enamel and dentin according to manufacturer's instructions followed by incremental build-up of composite resin on the top of resin cements. Each tooth was sectioned perpendicular to the resin-substrate interface with a slow speed diamond saw under water cooling yielding sections of approximately 1 mm(2). On an average, three sections from each tooth were used for testing. The beams obtained after sectioning were stressed to failure under tension in a custom made stainless steel forceps held in a universal testing machine (Lloyd) at a crosshead speed of 1.0 mm/min. Results were analyzed using two-way analysis of variance, independent t-test, and Tukey's HSD post-hoc test. RESULTS: Cements bonded to enamel substrates showed higher mean bond strength compared to dentin, which is statistically significant. Rely X ARC showed highest mean bond strength to both the substrates. CONCLUSION: There was a significant difference between the bond strength to enamel and dentin and, Rely X ARC resin cement showed higher bond strength compared with the other groups.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA