1.
J Heart Lung Transplant ; 19(11): 1077-80, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11077225

RESUMEN

BACKGROUND: A significant correlation between autofluorescence spectroscopy and heart allograft rejection has been described in the rat heterotropic allograft model. However, the use of this technique in human heart transplants has not been validate. METHODS: We obtained fluorescence and reflectance spectra on 37 human endomyocardial biopsy specimens and correlated the spectra with International Society Heart and Lung Transplantation grade for histologic rejection. RESULTS: Using different excitation wavelengths (ultraviolet, lambda = 337 nm; blue, lambda = 440 nm, and green, lambda = 486 nm), we found no significant difference in the fluorescence spectra among the different grades of rejection. CONCLUSIONS: Fluorescence spectroscopy is not a sensitive method for detecting rejection in human heart transplant recipients.


Asunto(s)
Endocardio/patología , Rechazo de Injerto/patología , Trasplante de Corazón/patología , Miocardio/patología , Espectrometría de Fluorescencia , Adulto , Anciano , Animales , Biopsia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Ratas , Procesamiento de Señales Asistido por Computador/instrumentación , Espectrometría de Fluorescencia/instrumentación