Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Heart Rhythm O2 ; 5(7): 460-467, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39119022

RESUMEN

Background: Single-shot devices are increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). The Arctic Front cryoballoon is the most frequently used single-shot technology. A recently developed novel pulsed field ablation (PFA) device (FARAPULSE) has been introduced with the aim to improve procedural safety and efficacy. Objective: This study will compare the novel FARAPULSE PFA device and the Arctic Front cryoballoon for first PVI in patients with symptomatic paroxysmal AF. Methods: SINGLE SHOT CHAMPION is a multicenter, randomized controlled trial with blinded endpoint adjudication by an independent clinical events committee. Overall, 210 patients with paroxysmal AF undergoing their PVI are randomized 1:1 between PFA and cryoballoon ablation. Continuous rhythm monitoring with an implantable cardiac monitor is performed in all patients. Results: The primary endpoint is time to first recurrence of any atrial tachyarrhythmia (AF and/or organized atrial tachyarrhythmia) lasting ≥120 seconds and identified by the implantable cardiac monitor within 91 and 365 days postablation. The composite procedural safety endpoint includes cardiac tamponade requiring drainage, persistent phrenic nerve palsy, vascular complications requiring intervention, stroke/transient ischemic attack, atrioesophageal fistula, and death occurring during or up to 30 days after the procedure. Key secondary endpoints include (1) increase in high-sensitivity troponin on day 1 postablation, (2) analysis of postablation 3-dimensional electroanatomic mapping (first 25 patients per study group), (3) AF burden, and (4) quality-of-life changes. Conclusion: SINGLE SHOT CHAMPION will evaluate the efficacy and safety of PVI using the novel FARAPULSE PFA for patients with symptomatic paroxysmal AF.

2.
Eur Heart J Suppl ; 26(Suppl 4): iv61-iv68, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39099576

RESUMEN

Rhythm control in patients with atrial fibrillation (AF) has evolved dramatically in the last decades. Several studies have informed us of the benefits of an early rhythm control strategy and primary rhythm control by catheter ablation (CA). Similarly, several studies have investigated the effects of CA in patients with longer AF duration and more comorbidities, especially heart failure. In the current review, we summarize the current evidence on rhythm control at different time points during the disease course of AF [Table 1 and Central illustration].

3.
Eur Heart J Case Rep ; 8(8): ytae359, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39108996

RESUMEN

Background: We report endocardial radiofrequency (RF) ablation as an alternative treatment approach for a symptomatic patient with obstructive hypertrophic cardiomyopathy (oHCM), who is not suitable for surgical septal myectomy or alcohol septal ablation. Endocardial RF ablation, with detailed 3D mapping of the intrinsic conducting system, offers the possibility of reducing the risk of complete heart block rates and of effectively relieving symptoms. Case summary: We present a symptomatic 51-year-old female patient with oHCM and a maximum left ventricular outflow tract (LVOT) gradient of 148 mmHg. Because of alcohol septal ablation failure, endocardial RF ablation in combination with detailed mapping of the intrinsic conduction system and intraprocedural imaging was performed. The 6-month follow-up showed a significant improvement in exercise tolerance, no relevant dynamic LVOT obstruction with a gradient of 22 mmHg under Valsalva. Discussion: In the current case report, endocardial RF ablation persistently reduced LVOT gradients in a patient with oHCM. Pre-interventional imaging, detailed 3D mapping of the conduction system, and correlation to intracardiac and transthoracic echocardiography were key for an effective and safe ablation of a small target zone.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39141267

RESUMEN

BACKGROUND AND AIMS: Catheter ablation is superior to pharmacological therapy in controlling atrial fibrillation (AF). There are few data on the long-term outcome of AF ablation in octogenarian patients. This analysis aims to evaluate the outcome of AF ablation in octogenarians vs. younger patients. METHODS: In this retrospective study in 13 centres in the UK, France, and Switzerland, the long-term outcomes of 473 consecutive octogenarian patients undergoing ablation for AF were compared to 473 matched younger controls (median age 81.3 [80.0, 83.0] vs. 64.4 [56.5, 70.7] years, 54.3% vs. 35.1% females; p-value for both < 0.001). The primary endpoint was the recurrence of atrial arrhythmia after a blanking period of 90 days within 365 days of follow-up. RESULTS: Acute ablation success as defined as isolation of all pulmonary veins was achieved in 97% of octogenarians. Octogenarians experienced more procedural complications (11.4% vs 7.0%, p = 0.018). The median follow-up time was 281 [106, 365] days vs. 354 [220, 365] days for octogenarians vs. non-octogenarians (p < 0.001). Among octogenarians, 27.7% (131 patients) experienced a recurrence of atrial arrhythmia, in contrast to 23.5% (111 patients) in the younger group (odds ratio 1.49; 95% confidence interval 1.16-1.92; p = 0.002). In a multivariable regression model including gender, previous AF ablation, vascular disease, chronic kidney disease, CHA2DS2-VASc score, left atrial dilatation, and indwelling cardiac implantable electronic device, age above 80 remained an independent predictor of recurrence of arrhythmia. CONCLUSION: Ablation for AF is effective in octogenarians, but is associated with slightly higher procedural complication rate and recurrence of atrial arrhythmia than in younger patients.

5.
Am J Med ; 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38977149

RESUMEN

BACKGROUND: This study investigated sex differences in acute myocarditis patients during index hospitalization. METHODS: We included 365 patients with acute myocarditis, hospitalized with continuous monitoring at the intensive care unit from 2000-2023 into the Basel Myocarditis Cohort study. We compared sex differences in clinical presentation, the presenting electrocardiogram, prior medical history, inflammatory and cardiac biomarkers, cardiac imaging, arrhythmia occurrence, and short- to midterm outcomes. RESULTS: Mean age was 41.3 years, and 26.3% were female. Compared with men, women were older (median 49.7 vs 38.3 years, P < .001) at the time of diagnosis and presented more frequently with dyspnea (41 vs 26%, P = .013) and a higher Killip class (P = .011). In the presenting electrocardiogram, men had a higher occurrence of diffuse ST-elevation (38 vs 9%, P < .001) and PQ-depression (31 vs 20%, P = .042), compared with women. Women had higher N-terminal pro B-type natriuretic peptide levels (1180 vs 387 ng/L, P = .015), lower cardiac troponin T levels (389 vs 726 ng/L, P = .006), and fewer segments with nonischemic late gadolinium enhancement on cardiac magnetic resonance imaging (1 vs 3, P = .005), but similar left ventricular ejection fraction (55 vs 55%, P = .629), compared with men. Overall, hospital stay was longer in women compared with men (7 vs 5 days, P = .018), with a similar length of intensive care unit stay (2.6 vs 2.7 days, P = .922). Women more often developed severe arrhythmia (8.3 vs 2.2%, P = .015) and heart failure during the hospitalization (31.3 vs 16.4%, P = .003). CONCLUSION: Compared with men, women with acute myocarditis were older at the time of diagnosis, presented more often with heart failure, and had an increased frequency of severe arrhythmia.

8.
Heart Rhythm ; 21(9): 1509-1516, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38762133

RESUMEN

BACKGROUND: Stroke remains one of the most serious complications in atrial fibrillation (AF) patients and has been linked to disturbances of the autonomic nervous system. OBJECTIVE: The purpose of this study was to test the hypothesis that impaired cardiac autonomic function might be associated with an enhanced stroke risk in AF patients. METHODS: A total of 1922 AF patients who were in either sinus rhythm (SR group; n = 1121) or AF (AF group; n = 801) on a 5-minute resting electrocardiographic (ECG) recording were enrolled in the study. Heart rate variability triangular index (HRVI), standard deviation of normal-to-normal intervals, root mean square root of successive differences of normal-to-normal intervals, mean heart rate, 5-minute total power, and power in the high-frequency, low-frequency, and very-low-frequency ranges were calculated. Cox regression models were constructed to examine the association of heart rate variability (HRV) parameters with the composite endpoint of stroke or systemic embolism. RESULTS: Mean age was 71 ± 8 years in the SR group and 75 ± 8 years in the AF group. Thirty-seven patients in the SR group (3.4%) and 60 patients in the AF group (8.0%) experienced a stroke or systemic embolism during follow-up of 5 years. In patients with SR, HRVI <15 was the strongest HRV parameter to be associated with stroke or systemic embolism (hazard ratio 3.04; 95% confidence interval 1.3-7.0; P = .009) after adjustment for multiple confounders. In the AF group, no HRV parameter was found to be associated with the composite endpoint. CONCLUSION: HRVI measured during SR on a single 5-minute ECG recording is independently associated with stroke or systemic embolism in AF patients. HRV analysis in SR may help to improve risk stratification in AF patients.


Asunto(s)
Fibrilación Atrial , Electrocardiografía , Frecuencia Cardíaca , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Masculino , Frecuencia Cardíaca/fisiología , Femenino , Anciano , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/etiología , Embolia/fisiopatología , Embolia/etiología , Embolia/diagnóstico , Sistema Nervioso Autónomo/fisiopatología , Factores de Riesgo , Estudios de Seguimiento , Incidencia , Estudios Retrospectivos , Medición de Riesgo/métodos
9.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1353-1364, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38819347

RESUMEN

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Complicaciones Posoperatorias , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Masculino , Femenino , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Complicaciones Posoperatorias/epidemiología , Incidencia , Taponamiento Cardíaco/epidemiología , Taponamiento Cardíaco/etiología , Accidente Cerebrovascular/epidemiología , Fístula Esofágica/epidemiología , Fístula Esofágica/etiología
10.
Eur Heart J Case Rep ; 8(5): ytae256, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38807945

RESUMEN

Background: Differentiation of syncope from seizure is challenging and has therapeutic implications. Cardioinhibitory reflex syncope typically affects young patients where permanent pacing should be avoided whenever possible. Cardioneuroablation may obviate the need for a pacemaker in well-selected patients. Case summary: A previously healthy 24-year-old woman was referred to the emergency department after recurrent episodes of transient loss of consciousness (TLOC). The electrocardiogram (ECG) and the echocardiogram were normal. An electroencephalogram (EEG) showed intermittent, generalized pathological activity. During EEG under photostimulation, the patient developed a short-term TLOC followed by brachial myocloni, while the concurrent ECG registered a progressive bradycardia, which turned into a complete atrioventricular block and sinus arrest with asystole for 14 s. Immediately after, the patient regained consciousness without sequelae. The episode was interpreted as cardioinhibitory convulsive syncope. However, due to the pathological EEG findings, an underlying epilepsy with ictal asystole could not be fully excluded. Therefore, an antiseizure therapy was also started. After discussing the consequences of pacemaker implantation, the patient agreed to undergo a cardioneuroablation and after 72 h without complications, she was discharged home. At 10 months, the patient autonomously discontinued the antiepileptics. The follow-up EEG displayed unspecific activities without clinical correlations. An implantable loop recorder didn't show any relevant bradyarrhythmia. At 1-year follow-up, the patient remained asymptomatic and without syncopal episodes. Discussion: Reflex syncope must be considered in the differential diagnosis of seizures. The cardioneuroablation obviated the need for a pacemaker and allowed for the withdrawal of anticonvulsants, originally started on the premise of seizure.

11.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1367-1376, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38752963

RESUMEN

BACKGROUND: Pulmonary vein isolation is an effective treatment for atrial fibrillation (AF). Cryoballoon ablation using the Arctic Front cryoballoon (Medtronic) was found to be superior to antiarrhythmic drug treatment. Recently, a novel cryoballoon system was introduced (PolarX, Boston Scientific). OBJECTIVES: The purpose of this study was to compare the efficacy and safety of the 2 cryoballoons in a randomized controlled trial. METHODS: Patients with symptomatic paroxysmal AF were enrolled in 2 centers and randomized 1:1 to pulmonary vein isolation using the PolarX or the Arctic Front cryoballoon. All patients received an implantable cardiac monitor. The primary endpoint was first recurrence of atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia [AT]) between days 91 and 365. Procedural safety was assessed by a composite of tamponade, phrenic nerve palsy lasting >24 hours, vascular complications, stroke/transient ischemic attack, atrioesophageal fistula or death up to 30 days. RESULTS: A total of 201 patients were enrolled. At 1 year, recurrence of atrial tachyarrhythmia had occurred in 41 of 99 patients (41.6%) assigned to the PolarX group and in 48 of 102 patients (47.1%) assigned to the Arctic Front group (HR: 0.85 [95% CI: 0.56-1.30]; P = 0.03 for noninferiority; P = 0.46 for superiority). The safety endpoint occurred in 5 patients (5%) in the PolarX group (n = 5 phrenic nerve palsies lasting >24 hours), whereas no safety endpoints occurred in the Arctic Front group (P = 0.03). CONCLUSIONS: In this randomized controlled trial using implantable cardiac monitors for continuous rhythm monitoring, the novel PolarX cryoballoon was noninferior compared with the Arctic Front cryoballoon regarding efficacy. However, the PolarX balloon resulted in significantly more phrenic nerve palsies. (Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF [COMPARE-CRYO]; NCT04704986).


Asunto(s)
Fibrilación Atrial , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Masculino , Femenino , Criocirugía/métodos , Criocirugía/instrumentación , Persona de Mediana Edad , Anciano , Venas Pulmonares/cirugía , Resultado del Tratamiento , Recurrencia , Nervio Frénico/lesiones
12.
Heart Rhythm ; 21(9): 1581-1588, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38614192

RESUMEN

BACKGROUND: Atrial fibrillation (AF) and heart failure frequently coexist. Prediction of left ventricular ejection fraction (LVEF) recovery after catheter ablation (CA) for AF remains difficult. OBJECTIVE: The purpose of this study was to evaluate the value of biomarkers, alone and in combination with the Antwerp score, to predict LVEF recovery after CA for AF. METHODS: Patients undergoing CA for AF with depressed LVEF (<50%) were included. Plasma levels of 13 biomarkers were measured immediately before CA. Patients were categorized into "responders" and "nonresponders" in a similar fashion to the Antwerp score performance derivation and validation cohorts. The predictive power of the biomarkers alone and combined in outcome prediction was evaluated. RESULTS: A total of 208 patients with depressed LVEF were included (median age 63 years; 39-19% female; median indexed left atrial volume 42 (33-52) mL/m2; median LVEF 43 (38-46)%). At a median follow-up time of 30 (20-34) months, 161 (77%) were responders and 47 (23%) were nonresponders. Of 13 biomarkers, -4-angiopoietin 2 (ANG2), growth differentiation factor 15 (GDF15), fibroblast growth factor 23, and myosin binding protein C3-were significantly different between responders and nonresponders (P ≤ .001) and their combination could predict the end point with an area under the curve of 0.72 (95% confidence interval [CI] 0.64-0.81) overall, 0.69 (95% CI 0.59-0.78) in heart failure with mildly reduced ejection fraction, and 0.88 (95% CI 0.77-0.98) in heart failure with reduced ejection fraction. Only ANG2 and GDF15 remained significantly associated with LVEF recovery after adjustment for age, sex, and Antwerp score and significantly improved the accuracy of the Antwerp score predictions (P < .001). The area under the curve of the Antwerp score in the outcome prediction improved from 0.75 (95% CI 0.67-0.83) to 0.78 (95% CI 0.70-0.86). CONCLUSION: A biomarker panel (ANG2 and GDF15) significantly improved the accuracy of the Antwerp score.


Asunto(s)
Fibrilación Atrial , Biomarcadores , Ablación por Catéter , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Ablación por Catéter/métodos , Volumen Sistólico/fisiología , Persona de Mediana Edad , Biomarcadores/sangre , Función Ventricular Izquierda/fisiología , Recuperación de la Función , Factor 15 de Diferenciación de Crecimiento/sangre , Estudios de Seguimiento , Anciano
13.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38607938

RESUMEN

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Sistema de Registros , Reoperación , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Anciano , Factores de Tiempo , Suiza/epidemiología , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos
15.
Heart Rhythm O2 ; 5(2): 113-121, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38545324

RESUMEN

Background: Infranodal conduction disorders are common after transcatheter aortic valve replacement (TAVR). Risk factors are incompletely understood. Objective: The purpose of this study was to assess the impact of valve implantation depth and calcium burden of the device landing zone on infranodal conduction intraprocedure pre- and post-TAVR. Methods: In all patients undergoing TAVR between June 2020 and June 2021, the His-ventricle (HV) interval was measured pre- and post-valve deployment. The difference between the 2 measurements defined delta HV, whereas infranodal conduction delay was defined as HV interval >55 ms. Valve implantation depth was measured as the distance between the aortic annular plane and the ventricular prosthesis end. Calcium burden was quantified as the volume of calcium in 6 regions of interest: the non-, right, and left coronary cusps (NCC, RCC, and LCC, respectively) and the corresponding regions of the left ventricular outflow tract (LVOT) underlying each cusp (LVOTNCC, LVOTRCC, LVOTLCC, respectively). Results: Of 101 patients (mean age 81 ± 5.7 years; 47% women), 37 demonstrated infranodal conduction delay intraprocedure post-TAVR. Overall, mean implantation depth was 5 ± 3.1 mm, median calcium volume was 2080 mm3 [interquartile range 632-2400]. Delta HV showed no correlation with implantation depth or calcium burden (r = -0.08 and r = 0.12, respectively). However, LVOTNCC calcification was a significant predictor for infranodal conduction delay post-valve deployment in a multivariable logistic regression model (odds ratio 1.62 per 100-mm3 increase (95% confidence interval 1.06-2.69; P = .04). Conclusion: Assessment of LVOTNCC calcification may identify patients at risk for infranodal conduction delay after TAVR, whereas implantation depth did not predict infranodal conduction delay.

17.
J Interv Card Electrophysiol ; 67(6): 1359-1364, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38182965

RESUMEN

BACKGROUND: Non-pulmonary vein (PV) ablation targets such as posterior wall isolation (PWI) have been tested in patients with persistent atrial fibrillation (AF). Pulsed-field ablation (PFA) offers a novel ablation technology possibly able to overcome the obstacles of incomplete PWI and concerns of damage to adjacent structures compared to thermal energy sources. Our aim was to assess procedural characteristics, safety, and mid-term outcomes of patients undergoing PWI using PFA in a clinical setting. METHODS: Patients undergoing PFA-PVI with PWI were included. First-pass isolation was controlled using a multipolar mapping catheter. RESULTS: One hundred consecutive patients were included (median age 69 [IQR 63-75] years, 33 females (33%), left atrial size 43 [IQR 39-47] mm, paroxysmal AF 24%). Median procedure time was 66 (IQR 59-77) min, and fluoroscopy time was 11 (8-14) min. PWI using PFA was achieved in 100% of patients with a median of 19 applications (IQR 14-26). There were no major complications. Overall, in 15 patients (15%), recurrent AF/AT was noted during a median follow-up of 144 (94-279) days. CONCLUSIONS: PWI using PFA appears safe and results in high acute isolation rates and high arrhythmia survival during mid-term follow-up. Further randomized trials are essential and warranted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Femenino , Masculino , Fibrilación Atrial/cirugía , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Tempo Operativo , Fluoroscopía , Recurrencia
18.
J Hypertens ; 42(4): 662-671, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38288945

RESUMEN

OBJECTIVE: There is an increasing number of cuffless blood pressure (BP) measurement (BPM) devices. Despite promising results when comparing single measurements, the ability of these devices to track changes in BP levels over 24 h related to an initial calibration BP (CalibBP) is unknown. Our aim was to analyse this ability in a cuffless device using pulse transit time. METHODS: We prospectively enrolled 166 participants for simultaneously performed cuffless (Somnotouch-NIBP) and cuff-based (Spacelabs 90217A/IEM Mobil-O-graph) 24 h BPM. As CalibBP for the cuffless device, first cuff-based BP was used. As surrogate for changes in BP levels after the CalibBP, we used the difference between the CalibBP and mean 24 h, awake and asleep BP measured by the two devices. In addition, we analysed the relationship between the difference of the CalibBP and the cuff-based BPM versus the difference between the cuff-based and the cuffless BPM devices. RESULTS: Mean(SD) difference between the CalibBP and mean 24hBP by the cuff-based or cuffless BP device were 7.4 (13.2) versus 1.8 (8.3) mmHg for systolic ( P  < 0.0001) and 6.6 (6.8) versus 1.6 (5.8) mmHg for diastolic ( P  < 0.0001). A near linear relationship was seen among the difference between the CalibBP and the cuff-based BPM values and the difference between the cuff-based and cuffless BPM device. CONCLUSION: Our data indicate a lower ability of the cuffless BPM device to track changes of BP levels after CalibBP. In addition, cuffless device accuracy was associated with the changes in BP levels after the initial CalibBP - the larger the BP level change, the larger the difference between the devices. REGISTRATION: https://www.clinicaltrials.gov ; Unique identifier: NCT03054688; NCT03975582.


Asunto(s)
Determinación de la Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Humanos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Esfigmomanometros , Presión Arterial
20.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38036293

RESUMEN

AIMS: Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS: One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION: Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA