Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Ultrasound ; 50(8): 1143-1150, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36218212

RESUMEN

Coronary microvascular dysfunction is present in two-thirds of patients showing symptoms and signs of myocardial ischemia. Their microcirculation has abnormalities due to endothelial and smooth muscle cell dysfunction. Impairment of this mechanism causes a high risk of adverse cardiovascular event. Diagnosing coronary microvascular dysfunction is challenging. Guidelines recommend the use of nuclear medicine procedures in the above-mentioned indications. Myocardial perfusion imaging with positron emission tomography is a novel procedure with high diagnostic accuracy and quality of images. It has short acquisition, low effective radiation dose and prognostic factors. There are still unknowns about this procedure and all its benefits.


Asunto(s)
Enfermedad de la Arteria Coronaria , Isquemia Miocárdica , Imagen de Perfusión Miocárdica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Circulación Coronaria/fisiología , Humanos , Microcirculación/fisiología , Isquemia Miocárdica/diagnóstico por imagen , Imagen de Perfusión Miocárdica/efectos adversos , Imagen de Perfusión Miocárdica/métodos
2.
Endokrynol Pol ; 68(3): 352-359, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28660992

RESUMEN

INTRODUCTION: 18F-deoxy-glucose positron emission tomography combined with computed tomography (18F-FDG PET/CT) is routinely used in the detection of malignant disease based on the property of malignant cells to fuel their growth and replication by increased glucose uptake. Malignant lesions are rare in the sellar region, while pituitary adenomas are the most common pathology. These are benign neoplasms with insidious onset and low proliferation activity, and therefore are only exceptionally detected by 18F-FDG PET/CT. Studies that compare the biology of pituitary adenomas and their radiological properties using PET/CT are still lacking. CASE REPORT: We investigate and discuss tumour biology in light of increased 18F-FDG avidity in a symptom-free, 70-year-old male patient, previously treated for two different malignancies (lung and rectal). Increased tracer accumulation in the sellar region was incidentally detected on a follow-up 18F-FDG PET/CT scan. Additional MRI disclosed pituitary adenoma. Normal hormonal status was found, consistent with the diagnosis of non-functioning pituitary adenoma. Analysis of tumour tissue after pituitary surgery confirmed a silent gonadotroph adenoma with low proliferation index. Low expression of oncogene-induced senescence markers did not support senescence as the explanation for the tumour's low proliferative activity although it was in consonance with the hormonal activity. CONCLUSIONS: Pituitary adenomas can manifest as hypermetabolic foci on 18F-FDG PET/CT imaging with increased tracer uptake even in indolent, clinically silent pituitary adenomas with low mitotic activity. Special attention should be paid to evaluation of 18F-FDG avid pituitary adenomas in patients with multiple malignancies, bearing in mind that avidity does not always mirror its biological behaviour.


Asunto(s)
Adenoma/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Neoplasias Hipofisarias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adenoma/cirugía , Anciano , Reacciones Falso Positivas , Humanos , Masculino , Neoplasias Hipofisarias/cirugía
3.
Hell J Nucl Med ; 18 Suppl 1: 81-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26665216

RESUMEN

OBJECTIVE: The aim of this study was to assess the value of (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT in detection of liver metastases in patients with suspected recurrent colorectal carcinoma, as well as to compare diagnostic performance of (18)F-FDG PET/CT with conventional imaging methods (MDCT). SUBJECTS AND METHODS: This study included 73 patients with resected primary colorectal adenocarcinoma referred for (18)F-FDG PET/CT to the National PET Center, at the Clinical Center of Serbia, Belgrade, from January 2010 to May 2013, with suspicion of recurrence. The patients underwent (18)F-FDG PET/CT examination on a 64-slice hybrid PET/CT scanner (Biograph, TruePoint64, Siemens Medical Solutions, Inc. USA). Prior to (18)F-FDG PET/CT all patients underwent contrast-enhanced MDCT. Findings of (18)F-FDG PET/CT and MDCT were compared to findings of subsequent histopathological examinations or with results of clinical and imaging follow-up over at least six months. Final diagnosis of liver metastases of colorectal cancer was made either by histopathological examination of specimen after biopsy or surgery, or based on clinical, laboratory and imaging evaluation during first six months after PET/CT scan. RESULTS: In detection of liver metastases (18)F-FDG PET/CT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 83.3%, 95.3%, 92.6%, 89.1% and 90.4%, respectively. In addition, MDCT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy in detection of liver metastases of 60%, 88.4%, 78.3%, 76% and 76.7%, respectively. There was significant difference in sensitivity (83.3% vs 60%; P=0.045) between these two methods. In addition, significant difference was observed in accuracy between PET/CT and MDCT (90.4% vs 76.7%; P=0.016). The higher specificity in visualization of liver metastases was also achieved by (18)F-FDG PET/CT compared to MDCT (95.3% vs 88.4%), but this difference was not significant (P=0.37). CONCLUSION: (18)F-FDG PET/CT was highly sensitive, specific and accurate method in detection of liver metastases in patients with suspected recurrent colorectal carcinoma in our study. This hybrid imaging showed superior diagnostic performance in evaluation of suspected colorectal cancer liver metastases compared to conventional imaging.

4.
Hell J Nucl Med ; 18(1): 35-41, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25840571

RESUMEN

OBJECTIVE: To prospectively study whether in patients with resected primary colorectal cancer fluorine- 18-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) examination could diagnose the stage, specify treatment procedure and be prognostic. SUBJECTS AND METHODS: This prospective study included 75 patients with resected primary colorectal adenocarcinoma referred for (18)F-FDG PET/CT to the National PET Center, at the Clinical Center of Serbia, Belgrade, from January 2010 to May 2013. Findings of (18)F-FDG PET/CT were compared to findings of subsequent histopathological examinations or with results of clinical and imaging follow-up. Patients were followed after PET/CT examination for a mean follow-up time of 16.7±5.9 months. RESULTS: In the detection of recurrent disease (18)F-FDG PET/CT showed overall sensitivity, specificity, PPV, NPV and accuracy of 96.6%, 82.4%, 94.9%, 87.5% and 93.3%, respectively. In the detection of stages I and II sensitivity, specificity and accuracy of (18)F-FDG PET/CT were: 88%, 96.6% and 94.7%, respectively, and in the detection of stages III and IV sensitivity, specificity and accuracy were 94.9%, 87.5% and 93.3%, respectively. These findings prevented or changed intended surgical treatment in 12/32 cases. Univariate and multivariate Cox proportional regression analyses revealed that metastatic recurrence (stages III and IV) was the only and independent prognostic factor of disease progression during follow-up (P=0.012 and P=0.023, respectively). Although, survival seemed better in patients with local recurrence compared to metastatic recurrent disease, this difference did not reach significance (Log-rank test; P=0.324). In addition, progression-free survival time was significantly longer in patients in whom (18)F-FDG PET/CT scan led to treatment changes (Log-rank test; P=0.037). CONCLUSION: (18)F-FDG PET/CT was sensitive and accurate for the detection and staging of local and metastatic recurrent colorectal carcinoma, with higher specificity in the detection of local recurrences. The (18)F-FDG PET/CT scan induced treatment changes in 30/75 patients, including 12/32 patients in which surgical treatment was previously planned, and progression free survival time was significantly longer in these patients.


Asunto(s)
Carcinoma/diagnóstico por imagen , Neoplasias Colorrectales/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Carcinoma/patología , Neoplasias Colorrectales/patología , Progresión de la Enfermedad , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Análisis Multivariante , Recurrencia Local de Neoplasia/diagnóstico , Pronóstico , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Recurrencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
5.
Clin Nucl Med ; 37(1): 14-20, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22157022

RESUMEN

PURPOSE: The aim of our study was to assess diagnostic accuracy of Tc-99m depreotide and Tc-99m-EDDA/HYNIC-TOC scintigraphy for evaluation of pulmonary lesions that appeared ambiguous on computed tomography (CT). MATERIAL AND METHODS: Forty-nine consecutive patients (37 men and 12 women; mean age, 60 ± 11 years) with 60 pulmonary lesions on chest radiography and CT were referred for nuclear imaging. They were prospectively allocated to undergo whole-body scintigraphy (WBS) and single photon emission computed tomography (SPECT) using either Tc-99m depreotide (26 patients, group 1) or Tc-99m-EDDA/HYNIC-TOC imaging (23 patients, group 2). Histologic findings after tissue biopsy served as a gold standard for determining diagnostic accuracy of the 2 somatostatin analogs. Visual assessment was complemented by semiquantitative analysis based on target to background ratio. RESULTS: Among the 32 pulmonary lesions scanned with Tc-99m depreotide, focal uptake was increased in 22 of 25 malignancies, whereas no uptake was found in 6 of 7 benign lesions (88% sensitivity, 85% specificity, and 88% accuracy) on both WBS and SPECT. Imaging of 28 pulmonary lesions with Tc-99m-EDDA/HYNIC-TOC had a similar diagnostic yield (sensitivity 87%, specificity 84%, and accuracy 86%). Overall, target to background ratios were higher on SPECT than WBS but not significantly different between groups 1 and 2 (SPECT 2.72 ± 0.70 vs. 2.71 ± 0.50, WBS 1.61 ± 0.32 vs. 1.62 ± 0.28, respectively). CONCLUSION: This study demonstrates that Tc-99m depreotide and Tc-99m-EDDA/HYNIC-TOC have similar diagnostic value for characterizing pulmonary lesions that appear ambiguous on CT.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Compuestos de Organotecnecio , Somatostatina/análogos & derivados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cintigrafía , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Nucl Med Commun ; 30(2): 148-54, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19077915

RESUMEN

OBJECTIVES: We used gated single-photon emission computed tomography methoxyisobutylisonitrile (SPECT MIBI) to (i) determine whether location of myocardial infarction (MI) and severity of perfusion abnormalities affect post-stress left ventricular function in patients with single-vessel coronary artery disease, and (ii) correlate changes between post-stress and rest ejection fraction (EF) with the severity of perfusion and regional wall motion abnormalities (RWMAs). METHODS: Eighty-eight patients with a history (> or =3 months) of anterior MI (n=45) or inferior MI (n=43) underwent a 2-day stress-rest gated SPECT MIBI. 4D-MSPECT software was used to calculate left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), EF, and the difference from post-stress to rest EF (EFs-EFr). Summed stress scores, summed rest scores, and summed difference scores (SDS) were calculated based on the 17-segment model. RWMAs were visually assessed using a 5-point score. RESULTS: Patients with anterior MI, compared with those with inferior MI, showed significantly greater perfusion abnormalities (summed stress score 11.0+/-5.5 vs. 7.5+/-2.4, P<0.01, summed rest score 7.4+/-4.7 vs. 5.2+/-1.9, P<0.01, SDS 3.3+/-1.0 vs. 1.9+/-1.0, P<0.05) and higher post-stress and rest RWMA (RWMSS 12.2+/-6.0 vs. 8.7+/-4.1, P<0.01, RWMRS 8.7+/-5.4 vs. 5.6+/-3.0, P<0.01). In 22 patients with anterior reversible ischemia in addition to fixed defect, post-stress and rest EDV and ESV were significantly larger and post-stress EF decreased more than in 21 patients with inferior MI (EDV 144.0+/-28.9 ml vs. 108.6+/-36.9 ml, ESV 70.6+/-22.2 ml vs. 53.4+/-20.5 ml, EFs-EFr -4.2+/-3.5% vs. -1.5+/-2.2%, P<0.01). SDS and RWMA were highly correlated with EFs-EFr. CONCLUSION: In patients with single-vessel coronary artery disease, the extent and severity of perfusion and RWMAs assessed by gated SPECT MIBI are greater after anterior MI than inferior MI. Global left ventricular function is significantly more affected after anterior MI only in patients with reversible ischemia in addition to fixed wall defect. Decrease in EF from post-stress to rest is closely associated with the severity of perfusion and RWMAs. Overall results suggest that the extent and severity of perfusion and RWMAs are more prominent in the myocardial region supplied by left anterior descending coronary artery than by right coronary artery, which may explain significantly worse post-stress left ventricular function after anterior MI.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Acumulación Sanguínea de Compuerta/métodos , Infarto del Miocardio/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/complicaciones , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Disfunción Ventricular Izquierda/complicaciones
7.
Otolaryngol Head Neck Surg ; 137(3): 405-11, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17765766

RESUMEN

OBJECTIVE: To determine the value of 201-thallium (201-Tl) and technetium-99m sestamibi (Tc-99m MIBI) single photon emission computed tomography (SPECT) for detecting primary undifferentiated carcinoma of nasopharyngeal type (UCNT), residual/recurrent tissue, and lymph node involvement. STUDY DESIGN AND SETTING: SPECT of head and neck was prospectively performed in 46 patients with a history of UCNT (201-Tl in 24 patients, Tc-99m MIBI in 22). CT/MRI findings, clinical follow-up, and pathohistological verification served as a gold standard for calculating sensitivity, specificity, and accuracy of each scintigraphic technique. Tumor-to-background index (T/Bg) was derived when SPECT findings were positive. RESULTS: Sensitivity of 201-Tl SPECT was 87 percent, with 78 percent specificity, 83 percent accuracy, and T/Bg of 4.05 +/- 1.50. Tc-99m MIBI SPECT had 85 percent sensitivity, 78 percent specificity, 82 percent accuracy, and T/Bg of 4.45 +/- 1.27. CONCLUSION AND SIGNIFICANCE: 201-Tl SPECT and Tc-99m MIBI SPECT are useful for detecting primary UCNT, residual/recurrent disease, and lymph node involvement. This use is particularly valuable after chemoradiotherapy when CT/MRI may be ambiguous.


Asunto(s)
Carcinoma/diagnóstico por imagen , Neoplasias Nasofaríngeas/diagnóstico por imagen , Radiofármacos , Tecnecio Tc 99m Sestamibi , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Carcinoma/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Nasofaríngeas/patología , Recurrencia Local de Neoplasia/diagnóstico , Neoplasia Residual , Valor Predictivo de las Pruebas , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA