1.
Sci Rep ; 14(1): 21296, 2024 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-39266612

RESUMEN

Motion-onset visual evoked potentials (MO VEPs) are robust to dioptric blur when low contrast and low spatial frequency patterns are used for stimulation. To reveal mechanisms of MO VEPs robustness, we studied whether the resistance to defocus persists even when using a high-contrast checkerboard using digital defocus in the emmetropic eyes of 13 subjects (males 20-60 years). We compared the dominant components of MO VEPs to pattern-reversal VEPs (PR VEP), which are sensitive to the blur. For stimulation, we used checkerboard patterns with 15´ and 60´ checks. To defocus the checkerboard, we rendered it with a second-order Zernike polynomial ( Z 2 0 ) with an equivalent defocus of 0, 2, or 4 D. For PR VEP, the checkerboards were reversed in terms of their contrast. To evoke MO VEP, the checkerboard of 60´ checks moved for 200 ms with a speed of 5 or 10 deg/s in the cardinal directions. The MO VEP did not change in peak time (P ≥ 0.0747) or interpeak amplitude (P > 0.0772) with digital blur. In contrast, for PR VEP, the results showed a decrease in interpeak amplitude (P ≤ 6.65ˑ10-4) and an increase in peak time (P ≤ 0.0385). Thus, we demonstrated that MO VEPs evoked by checkerboard, structure containing high spatial content, can be robust to defocus.


Asunto(s)
Potenciales Evocados Visuales , Humanos , Adulto , Masculino , Potenciales Evocados Visuales/fisiología , Persona de Mediana Edad , Adulto Joven , Femenino , Percepción de Movimiento/fisiología , Estimulación Luminosa
2.
Sci Rep ; 14(1): 4244, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38378903

RESUMEN

A rapid checkerboard pattern change is used to elicit pattern-reversal visual evoked potentials (PR VEPs). CRT or LCD monitors do not allow immediate reversal of the entire pattern. The study aimed to construct a new stimulator whose characteristics approximate an instantaneous reversal and verify whether the improvement is reflected in PR VEPs. A new stimulator using a matrix of 12 × 48 independent white square LEDs was designed and compared with LCDs and CRTs. The effect on the PR VEP peak times and amplitudes of N70, P100, and P140 waves was evaluated in ten subjects. The LED stimulator showed significantly better performance in the rate of change of illuminance, change of pattern, luminance settling and stability. The PR VEP amplitudes of N75, P100, and N140 did not show significant differences. The sum of interpeak amplitudes was significantly larger for the LCD than for the other monitors. The peak times of the waves evoked by the LED were shorter than those evoked by the LCD and CRT for the N75 wave and a check size of 30´. LED stimulators are a better alternative to CRTs for PR VEPs than current LCDs. LEDs also seem to be better than CRTs, but further research is necessary to obtain significant results.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA