Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Oncol Lett ; 23(2): 49, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34992682

RESUMEN

GTPases of immunity-associated protein 2 (GIMAP2) is a GTPase family member associated with T cell survival. However, its mechanisms of action in oral squamous cell carcinoma (OSCC) remain largely unknown. Therefore, the present study aimed to elucidate the possible role of GIMAP2 in OSCC development by investigating its expression levels and molecular mechanisms in OSCC. Reverse transcription quantitative PCR, immunoblotting and immunohistochemistry indicated that GIMAP2 expression was significantly upregulated (P<0.05) in OSCC-derived cell lines and primary OSCC specimens compared with that in their normal counterparts. GIMAP2-knockdown OSCC cells exhibited decreased cell growth, which was associated with cyclin-dependent kinase (CDK)4, CDK6 and phosphorylated Rb downregulation and p53 and p21 upregulation. In addition to cell cycle arrest, GIMAP2 affected anti-apoptotic functions in GIMAP2-knockdown cells by upregulating Bcl-2 and downregulating Bax and Bak. These findings indicated that GIMAP2 may significantly influence OSCC development and apoptosis inhibition and thus is a potential biomarker of OSCC.

3.
J Cataract Refract Surg ; 41(2): 334-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25661126

RESUMEN

PURPOSE: To retrospectively assess the demographics of patients having cataract surgery in eyes with previous laser in situ keratomileusis (LASIK). SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, and Sanno Hospital, Tokyo, Japan. DESIGN: Retrospective case series. METHODS: This study evaluated eyes of consecutive patients scheduled for cataract surgery after previous LASIK (Group 1). The control groups comprised eyes with axial lengths (ALs) matched with ALS in Group 1 (Group 2) and all eyes scheduled for cataract surgery (Group 3). Assessed were age, sex, corrected distance visual acuity, manifest refraction, keratometry (K) readings, corneal astigmatism, and corneal higher-order aberrations (HOAs). RESULTS: Group 1 comprised 40 eyes of 40 patients; Group 2, 606 eyes of 606 patients; and Group 3, 3642 eyes of 3642 patients. The mean age at cataract surgery of patients in Group 1 was 54.6 years ± 8.1 (SD), which was significantly younger than in Group 2 (by approximately 10 years) and Group 3 (by approximately 15 years) (P < .001, Student t test). In Group 1, 70.0% of patients were men, a significantly higher percentage than in Groups 2 and 3 (P < .05, Fisher exact test). The rate of corneal HOAs was significantly higher in Group 1 than in Groups 2 and 3 (P < .05, Student t test). There were no significant differences in other demographics except in K readings. CONCLUSION: A long AL and an increase in corneal HOAs might contribute to a tendency for cataract surgery to be performed earlier in eyes in which LASIK has been performed. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Asunto(s)
Catarata/epidemiología , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Implantación de Lentes Intraoculares/estadística & datos numéricos , Miopía/cirugía , Facoemulsificación/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Astigmatismo/epidemiología , Astigmatismo/fisiopatología , Longitud Axial del Ojo/patología , Paquimetría Corneal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Seudofaquia/epidemiología , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Estudios Retrospectivos , Agudeza Visual/fisiología
4.
Br J Ophthalmol ; 99(2): 177-83, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25147365

RESUMEN

AIM: To assess the clinical outcomes following the use of toric implantable collamer lenses (toric ICL, STAAR Surgical) for the correction of high myopic astigmatism with keratoconus. METHODS: This retrospective study evaluated 21 eyes of 11 patients with spherical equivalents of -9.70±2.33 D (mean±SD) and astigmatism of -3.21±1.56 D who underwent toric ICL implantation for keratoconus. Preoperatively, and at 1, 3 and 6 months and 1, 2 and 3 years postoperatively, we assessed the safety, efficacy, predictability, stability and adverse events of the surgery. RESULTS: The logarithm of the minimum angle of resolution (logMAR) uncorrected distance visual acuity (UDVA) and the logMAR corrected distance visual acuity (CDVA) were -0.06±0.11 and -0.12±0.09, respectively, at 3 years postoperatively. At 3 years, 67% and 86% of the eyes were within ±0.5 and ±1.0 D, respectively, of the targeted correction. Manifest refraction changes of 0.04±0.33 D occurred from 1 month to 3 years postoperatively. No significant change in manifest refraction (analysis of variance, p=0.989) or keratometry (p=0.951), or vision-threatening complications occurred during the observation period. CONCLUSIONS: Toric ICL implantation is beneficial according to measures of safety, efficacy, predictability and stability for the correction of refractive errors for keratoconus during a 3-year observation period. The disease did not progress even in the late-postoperative period, suggesting the viability of this procedure as a surgical option for the treatment of such eyes.


Asunto(s)
Astigmatismo/cirugía , Queratocono/cirugía , Implantación de Lentes Intraoculares , Miopía Degenerativa/cirugía , Lentes Intraoculares Fáquicas , Adulto , Astigmatismo/complicaciones , Astigmatismo/fisiopatología , Recuento de Células , Paquimetría Corneal , Endotelio Corneal/patología , Femenino , Estudios de Seguimiento , Humanos , Presión Intraocular/fisiología , Queratocono/complicaciones , Queratocono/fisiopatología , Masculino , Persona de Mediana Edad , Miopía Degenerativa/complicaciones , Miopía Degenerativa/fisiopatología , Refracción Ocular/fisiología , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual/fisiología
5.
J Cataract Refract Surg ; 40(12): 2019-24, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25447196

RESUMEN

PURPOSE: To compare the vision-related quality of life 5 years after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation and after wavefront-guided laser in situ keratomileusis (LASIK) for myopia. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. DESIGN: Retrospective case series. METHODS: Quality of life was measured with the National Eye Institute Refractive Error Quality of Life instrument in consecutive patients 5 years after pIOL implantation or wavefront-guided LASIK to correct myopia. RESULTS: Phakic IOL implantation was performed in 48 patients and LASIK in 55 patients. The scores for activity limitations, symptoms, appearance, and satisfaction with correction were significantly higher in the pIOL group than in the LASIK group (P<.05, Mann-Whitney U test). No significant differences in other scores were observed between the 2 groups (P ≥.05). The scores for near vision and dependence on correction were significantly higher in the younger subgroup than in the older subgroup with both techniques. CONCLUSIONS: Phakic IOL implantation may offer significant vision-related quality-of-life advantages (eg, fewer activity limitations and symptoms and better appearance and satisfaction with correction) over wavefront-guided LASIK for myopia in the long term. Moreover, refractive surgery may provide a better quality of life in younger patients.


Asunto(s)
Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Implantación de Lentes Intraoculares , Miopía/cirugía , Lentes Intraoculares Fáquicas , Calidad de Vida/psicología , Aberrometría , Actividades Cotidianas , Adolescente , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Refracción Ocular/fisiología , Estudios Retrospectivos , Perfil de Impacto de Enfermedad , Agudeza Visual/fisiología , Adulto Joven
6.
J Refract Surg ; 30(12): 806-11, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25437478

RESUMEN

PURPOSE: To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and wavefront-guided LASIK in eyes with myopic astigmatism. METHODS: Fifty-eight eyes of 41 patients undergoing FLEx and 49 eyes of 29 patients undergoing wavefront-guided LASIK to correct myopic astigmatism were examined. Visual acuity, cylindrical refraction, predictability of the astigmatic correction, and astigmatic vector components were compared between groups 6 months after surgery. RESULTS: There was no statistically significant difference in manifest cylindrical refraction (P = .08) or percentage of eyes within ± 0.50 diopter (D) of its refraction (P = .11) between the surgical procedures. The index of success in FLEx was statistically significantly better than that of wavefront-guided LASIK (P = .02), although there was no significant difference between the groups in other indices (eg, surgically induced astigmatism, target-induced astigmatism, astigmatic correction index, angle of error, difference vector, and flattening index). Subgroup analysis showed that FLEx had a better index of success (P = .02) and difference vector (P = .04) than wavefront-guided LASIK in the low cylinder subgroup; the angle of error in FLEx was significantly smaller than that of wavefront-guided LASIK in the moderate cylinder subgroup (P = .03). CONCLUSIONS: Both FLEx and wavefront-guided LASIK worked well for the correction of myopic astigmatism by the 6-month follow-up visit. Although FLEx had a better index of success than wavefront-guided LASIK when using vector analysis, it appears equivalent to wavefront-guided LASIK in terms of visual acuity and the correction of astigmatism.


Asunto(s)
Astigmatismo/cirugía , Sustancia Propia/cirugía , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Adulto , Astigmatismo/fisiopatología , Sustancia Propia/fisiopatología , Femenino , Humanos , Masculino , Miopía/fisiopatología , Refracción Ocular/fisiología , Estudios Retrospectivos , Agudeza Visual/fisiología , Adulto Joven
7.
J Refract Surg ; 29(10): 716-20, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23952844

RESUMEN

PURPOSE: To investigate the association between ocular dominance (sighting dominance) and refractive asymmetry in phakic patients. METHODS: This retrospective study included 3,012 patients with a mean age of 29.0 ± 5.3 years (range: 20 to 39 years). Refractive error was determined with cycloplegic refraction and axial length was determined with IOLMaster (Carl Zeiss Meditec, Dublin, CA). Ocular dominance was assessed using the hole-in-the-card test. RESULTS: The right and left eyes were dominant in 77.7% and 22.3% of the patients, respectively. In the high anisometropia group (⩾ 2.0 diopters), the non-dominant eyes had significantly higher myopic spherical equivalents and longer axial lengths than the dominant eyes (P < .05). However, there were no significant differences in these parameters in the low anisometropia group. CONCLUSION: The current study revealed that non-dominant eyes had a greater myopic refractive error and longer axial length than the dominant eyes, especially in the patients who had high amounts of anisometropia.


Asunto(s)
Anisometropía/fisiopatología , Predominio Ocular/fisiología , Adulto , Anisometropía/diagnóstico , Longitud Axial del Ojo , Femenino , Humanos , Masculino , Midriáticos/administración & dosificación , Pupila/efectos de los fármacos , Refracción Ocular/fisiología , Estudios Retrospectivos , Agudeza Visual/fisiología , Adulto Joven
8.
PLoS One ; 8(2): e56453, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23409187

RESUMEN

PURPOSE: To assess the 3-year clinical outcomes of toric phakic intraocular lens (Visian ICL™; STAAR Surgical) implantation for moderate to high myopic astigmatism. METHODS: This retrospective study evaluated fifty eyes of 28 patients who underwent toric ICL implantation for the correction of moderate to high myopic astigmatism and who regularly returned for postoperative examination. Before, and 1, 3, and 6 months after, and 1, 2, and 3 years after surgery, we assessed the safety, efficacy, predictability, stability, and adverse events of the surgery in eyes undergoing toric ICL implantation. RESULTS: The logarithm of the minimal angle of resolution (LogMAR) uncorrected visual acuity and LogMAR best spectacle-corrected visual acuity were -0.10 (corresponding to Snellen equivalents 20/16) ± 0.16 and -0.20 (corresponding to 20/12.5) ± 0.07, 3 years postoperatively, respectively. The safety and efficacy indices were 1.16 ± 0.20 and 0.94 ± 0.28. At 3 year, 82% and 98% of the eyes were within 0.5 and 1.0 D, respectively, of the targeted correction. Manifest refraction changes of -0.15 ± 0.31 D occurred from 1 month to 3 year. No vision-threatening complications occurred during the observation period. CONCLUSIONS: On the basis of the clinical results of this study, toric ICL implantation was good in all measures of safety, efficacy, predictability, and stability for the correction of moderate to high myopic astigmatism throughout a 3-year observation period.


Asunto(s)
Astigmatismo/complicaciones , Implantación de Lentes Intraoculares/instrumentación , Miopía/complicaciones , Miopía/cirugía , Lentes Intraoculares Fáquicas , Adulto , Recuento de Células , Células Endoteliales/patología , Femenino , Estudios de Seguimiento , Humanos , Presión Intraocular , Implantación de Lentes Intraoculares/efectos adversos , Masculino , Persona de Mediana Edad , Miopía/patología , Miopía/fisiopatología , Lentes Intraoculares Fáquicas/efectos adversos , Estudios Retrospectivos , Seguridad , Resultado del Tratamiento , Adulto Joven
9.
Br J Ophthalmol ; 97(8): 968-75, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23269682

RESUMEN

AIM: To compare postoperative visual acuity, higher-order aberrations (HOAs) and corneal asphericity after femtosecond lenticule extraction (FLEx) and after wavefront-guided laser-assisted in situ keratomileusis (wfg-LASIK) in myopic eyes. METHODS: We examined 43 eyes of 23 patients undergoing FLEx and 34 eyes of 19 patients undergoing wfg-LASIK to correct myopia. Ocular HOAs were measured by Hartmann-Shack aberrometry and corneal asphericity was measured by a rotating Scheimpflug imaging system before and 3 months after surgery. RESULTS: There was no statistically significant difference in uncorrected (p=0.66 Mann-Whitney U-test) or corrected distance visual acuity (p=0.14) after two surgical procedures. For a 6-mm pupil, the changes in fourth-order aberrations after FLEx were statistically significantly less than those after wfg-LASIK (p<0.001). On the other hand, there were no statistically significant differences in the changes in third-order aberrations (p=0.24) and total HOAs (p=0.13). Similar results were obtained for a 4-mm pupil. The positive changes in the Q value after FLEx were statistically significantly less than those after wfg-LASIK (p=0.001). CONCLUSIONS: In myopic eyes, FLEx induces significantly fewer ocular fourth-order aberrations than wfg-LASIK, possibly because it causes less oblation in the corneal shape, but there was no statistically significant difference in visual acuity or in the induction of third-order aberrations and total HOAs. It is suggested that FLEx is essentially equivalent to wfg-LASIK in terms of visual acuity and total HOA induction, although the characteristics of HOA induction are different.


Asunto(s)
Córnea/patología , Aberración de Frente de Onda Corneal/prevención & control , Queratomileusis por Láser In Situ , Láseres de Excímeros/uso terapéutico , Terapia por Luz de Baja Intensidad , Miopía/cirugía , Agudeza Visual/fisiología , Aberrometría , Adolescente , Adulto , Córnea/cirugía , Aberración de Frente de Onda Corneal/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Periodo Posoperatorio , Estudios Retrospectivos , Colgajos Quirúrgicos , Adulto Joven
10.
J Cataract Refract Surg ; 38(8): 1408-13, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22814047

RESUMEN

PURPOSE: To assess the time course of refractive and corneal astigmatism after laser in situ keratomileusis (LASIK) in eyes with moderate to high astigmatism. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. DESIGN: Retrospective case series. METHODS: Keratometric readings and corneal astigmatism were determined with an autokeratometer in consecutive patients who had LASIK for moderate to high astigmatism (≥2.00 diopters [D]). RESULTS: The study enrolled 48 eyes of 35 patients with a mean age of 34.0 years ± 8.1 (SD), a mean spherical error of -5.10 ± 2.11 D, and a mean cylindrical error of -2.74 ± 0.99 D. Postoperatively, the mean spherical refraction changed significantly from 0.38 ± 0.80 D at 1 week to -0.13 ± 0.90 D at 1 year (P<.001, Wilcoxon signed-rank test). The mean cylindrical refraction showed no significant change (-0.67 ± 0.54 D at 1 week to -0.63 ± 0.63 D at 1 year) (P=.54). There were significant increases in the flattest and steepest keratometry readings at 1 week and at 1 year. However, no significant change in corneal astigmatism was found at either time point (P=.10). CONCLUSIONS: After LASIK, there was significant refractive regression in the spherical component but not in the cylindrical component. This suggests that refractive regression occurs by corneal steepening in the spherical component and that astigmatic regression does not occur, even in moderately to highly astigmatic eyes. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Asunto(s)
Astigmatismo/cirugía , Córnea/fisiopatología , Queratomileusis por Láser In Situ , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Refracción Ocular/fisiología , Adulto , Astigmatismo/fisiopatología , Topografía de la Córnea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Periodo Posoperatorio , Estudios Retrospectivos , Factores de Tiempo , Agudeza Visual/fisiología , Adulto Joven
11.
Am J Ophthalmol ; 153(6): 1178-86.e1, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22365084

RESUMEN

PURPOSE: To compare postoperative visual function after implantable collamer lens (ICL) implantation and after wavefront-guided laser in situ keratomileusis (LASIK) in eyes with low to moderate myopia. DESIGN: Retrospective observational case study. PATIENTS AND METHODS: We investigated 30 eyes of 20 patients undergoing ICL implantation and 64 eyes of 38 patients undergoing wavefront-guided LASIK for the correction of low to moderate myopia (manifest spherical equivalent: -3.00 to -5.88 diopters [D]). Ocular higher-order aberrations (HOAs) and contrast sensitivity (CS) function were measured by Hartmann-Shack aberrometry and a contrast sensitivity unit before and 3 months after surgery, respectively. From the contrast sensitivity, the area under the log contrast sensitivity function was calculated. RESULTS: For 4-mm and 6-mm pupils, the changes in ocular third-order aberrations, fourth-order aberrations, and total HOAs after ICL implantation were significantly less than those after wavefront-guided LASIK (P < .05, Mann-Whitney U test). The postoperative area under the log contrast sensitivity function was significantly increased after ICL implantation (P < .001), whereas, after wavefront-guided LASIK, it was not significantly changed (P = .11). CONCLUSIONS: ICL implantation induces significantly fewer ocular HOAs than wavefront-guided LASIK. Moreover, CS was significantly improved after ICL implantation but unchanged after wavefront-guided LASIK in eyes with low to moderate myopia. Thus, even in the correction of low to moderate myopia, ICL implantation appears to be superior in visual performance to wavefront-guided LASIK, suggesting that it may be a viable surgical option for the treatment of such eyes.


Asunto(s)
Queratomileusis por Láser In Situ , Láseres de Excímeros/uso terapéutico , Implantación de Lentes Intraoculares , Miopía/cirugía , Lentes Intraoculares Fáquicas , Segmento Posterior del Ojo/cirugía , Agudeza Visual/fisiología , Aberrometría , Adolescente , Adulto , Sensibilidad de Contraste/fisiología , Córnea/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miopía/clasificación , Miopía/fisiopatología , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Estudios Retrospectivos , Adulto Joven
12.
Graefes Arch Clin Exp Ophthalmol ; 249(7): 1073-80, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20953620

RESUMEN

BACKGROUND: To assess the early clinical outcomes of toric implantable collamer lenses (toric ICL™, STAAR Surgical) for the correction of high myopic astigmatism with keratoconus. METHODS: This study evaluated 27 eyes of 14 patients with spherical equivalents of -10.11 ± 2.46 D (mean ± standard deviation) and astigmatism of -3.03 ± 1.58 D who underwent toric ICL implantation for mild keratoconus. Before, and 1, 3 and 6 months after surgery, we assessed the safety, efficacy, predictability, stability, and adverse events of the surgery. RESULTS: LogMAR uncorrected visual acuity (UCVA) and LogMAR best spectacle-corrected visual acuity (BSCVA) were -0.09 ± 0.16 and -0.15 ± 0.09 respectively, 6 months after surgery. The safety and efficacy indices were 1.12 ± 0.18 and 1.01 ± 0.25. At 6 months, 85% and 96% of the eyes were within ±0.5 and ±1.0 D respectively of the targeted correction. Manifest refraction changes of 0.00 ± 0.35 D occurred from 1 week to 6 months. No vision-threatening complications occurred during the observation period. CONCLUSIONS: Toric ICL implantation was good in all measures of safety, efficacy, predictability, and stability for the correction of spherical and cylindrical errors in eyes with early keratoconus throughout the 6-month follow-up period, suggesting its viability as a surgical option for the treatment of such eyes.


Asunto(s)
Astigmatismo/cirugía , Queratocono/cirugía , Implantación de Lentes Intraoculares , Miopía Degenerativa/cirugía , Lentes Intraoculares Fáquicas , Segmento Posterior del Ojo/cirugía , Adulto , Astigmatismo/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Presión Intraocular , Queratocono/fisiopatología , Masculino , Persona de Mediana Edad , Miopía Degenerativa/fisiopatología , Refracción Ocular/fisiología , Resultado del Tratamiento , Agudeza Visual/fisiología
13.
Ophthalmology ; 117(12): 2287-94, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20598749

RESUMEN

OBJECTIVE: To assess the 1-year clinical outcomes of toric Visian Implantable Collamer Lens (ICL; STAAR Surgical, Nidau, Switzerland) implantation for moderate to high myopic astigmatism. DESIGN: Prospective, observational case series. PARTICIPANTS: Fifty-six eyes of 32 consecutive patients, with spherical equivalent errors of -4.00 to -17.25 diopters (D) and cylindrical errors of -0.75 to -4.00 D, who underwent toric ICL implantation. METHODS: Before and 1 week and 1, 3, 6, and 12 months after surgery, the safety, efficacy, predictability, stability, and adverse events of the surgery were assessed in eyes undergoing toric ICL implantation. Ocular higher-order aberrations (HOAs) and contrast sensitivity (CS) function also were evaluated before and 1 year after surgery. MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), safety index, efficacy index, predictability, stability, adverse events, HOAs, and CS function. RESULTS: The logarithm of the minimum angle of resolution (logMAR) UCVA and logMAR BSCVA were -0.11 (corresponding to Snellen equivalent 20/16) ± 0.12 and -0.19 (corresponding to 20/12.5) ± 0.08 1 year after surgery, respectively. The safety and efficacy indices were 1.17 ± 0.21 and 1.00 ± 0.29. At 1 year, 91% and 100% of the eyes were within 0.5 and 1.0 D, respectively, of the targeted correction. Manifest refraction changes of -0.07 ± 0.27 D occurred from 1 week to 1 year. For a 4-mm pupil, fourth-order aberrations were changed, not significantly, from 0.05 ± 0.02 µm before surgery to 0.06 ± 0.03 µm after surgery (P = 0.38, Wilcoxon signed-rank test). Similarly, for a 6-mm pupil, fourth-order aberrations were not significantly changed, merely from 0.20 ± 0.08 µm before surgery to 0.23 ± 0.11 µm after surgery (P = 0.15). The area under the log CS function was significantly increased from 1.41 ± 0.15 before surgery to 1.50 ± 0.13 after surgery (P < 0.001). No vision-threatening complications occurred during the observation period. CONCLUSIONS: In the authors' experience, the toric ICL performed well in correcting moderate to high myopic astigmatism during a 1-year observation period, suggesting its viability as a surgical option for the treatment of such eyes.


Asunto(s)
Astigmatismo/cirugía , Implantación de Lentes Intraoculares , Miopía Degenerativa/cirugía , Lentes Intraoculares Fáquicas , Adulto , Astigmatismo/fisiopatología , Recuento de Células , Sensibilidad de Contraste/fisiología , Pérdida de Celulas Endoteliales de la Córnea/patología , Femenino , Estudios de Seguimiento , Humanos , Presión Intraocular , Masculino , Persona de Mediana Edad , Miopía Degenerativa/fisiopatología , Segmento Posterior del Ojo , Estudios Prospectivos , Resultado del Tratamiento , Agudeza Visual/fisiología , Adulto Joven
14.
J Cataract Refract Surg ; 36(1): 164-6, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20117720

RESUMEN

UNLABELLED: We report a case in which toric intraocular Collamer lenses (ICLs) effectively corrected the refractive errors of pellucid marginal degeneration (PMD). Preoperatively, in the patient's right eye, the manifest refraction was -10.5 -3.5 x 55, the uncorrected distance visual acuity (UDVA) was 20/1000, and the corrected distance visual acuity (CDVA) was 20/16; in the left eye, the manifest refraction was -11.0 - 6.5 x 130 and the UDVA and CDVA were 20/1000 and 20/20, respectively. After bilateral implantation of a toric ICL, in the right eye, the manifest refraction was +1.50 - 0.75 x 10, the UDVA was 20/16, and the CDVA was 20/12.5; in the left eye, the manifest refraction was +2.5 -3.25 x 125 and the UDVA and CDVA were 20/40 and 20/16, respectively. No sign of progressive disease and no vision-threatening complication were observed during the 6-month follow-up. Toric ICL implantation may be a viable surgical option for the correction of high myopic astigmatism in eyes with PMD. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.


Asunto(s)
Astigmatismo/cirugía , Distrofias Hereditarias de la Córnea/cirugía , Implantación de Lentes Intraoculares , Miopía Degenerativa/cirugía , Lentes Intraoculares Fáquicas , Adulto , Astigmatismo/etiología , Astigmatismo/fisiopatología , Distrofias Hereditarias de la Córnea/complicaciones , Distrofias Hereditarias de la Córnea/fisiopatología , Topografía de la Córnea , Femenino , Humanos , Miopía Degenerativa/etiología , Miopía Degenerativa/fisiopatología , Refracción Ocular/fisiología , Agudeza Visual/fisiología
15.
Cornea ; 29(1): 99-101, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19907310

RESUMEN

PURPOSE: To report on a patient in whom hyperopic Implantable Collamer Lenses (ICL, STAAR Surgical, Nidau, Switzerland) and limbal relaxing incisions have been beneficial for the correction of hyperopic astigmatism after laser in situ keratomileusis (LASIK). METHODS: The 48-year-old man had undergone LASIK to correct high myopia 5 years earlier. Preoperatively, the manifest refraction was +2.25, -1.00 x 160, with an uncorrected visual acuity of 0.15 and a best spectacle-corrected visual acuity of 1.5. RESULTS: Postoperatively, the manifest refraction was +0.50, -0.5 x 165, with an uncorrected visual acuity of 1.0 and a best spectacle-corrected visual acuity of 1.2. No serious complications were observed during the 10-month observation period. CONCLUSION: Hyperopic Implantable Collamer Lenses implantation combined with limbal relaxing incisions may be an alternative for the treatment of hyperopic astigmatism after overcorrected myopic LASIK.


Asunto(s)
Astigmatismo/cirugía , Hiperopía/cirugía , Queratomileusis por Láser In Situ/efectos adversos , Implantación de Lentes Intraoculares , Limbo de la Córnea/cirugía , Lentes Intraoculares Fáquicas , Astigmatismo/etiología , Topografía de la Córnea , Humanos , Hiperopía/etiología , Masculino , Persona de Mediana Edad , Miopía/cirugía , Refracción Ocular/fisiología , Agudeza Visual/fisiología
16.
Jpn J Ophthalmol ; 53(5): 458-63, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19847598

RESUMEN

PURPOSE: To compare postoperative outcomes of a new aspheric laser in situ keratomileusis (LASIK) system, which applies an index for corneal asphericity (Q-value), with outcomes of the conventional LASIK procedure. METHODS: Twenty-eight eyes of 15 consecutive patients (mean age, 36.4 +/- 5.8 years) underwent aspheric LASIK (As-LASIK group), and 33 eyes of 18 consecutive patients (mean age, 32.9 +/- 8.3 years) underwent conventional LASIK (Con-LASIK group) at Sanno Hospital (Tokyo, Japan). Both procedures were performed with a Moria LSK-One microkeratome and a Bausch and Lomb Technolas 217-z100 excimer laser. Preoperative mean spherical equivalent refraction values were -5.13 +/- 1.23 diopters (D) and -5.63 +/- 0.88 D in the As-LASIK and Con-LASIK groups, respectively. Higher order aberrations were measured and contrast sensitivity was assessed at 3 months after the procedure, and these, along with safety, efficacy, and predictability, were compared between the two procedures. RESULTS: Conventional LASIK significantly increased higher order aberrations and reduced contrast sensitivity, whereas As-LASIK did not increase spherical-like aberrations or alter contrast sensitivity. CONCLUSIONS: Aspheric LASIK may be a better laser technique than Con-LASIK, with less postoperative increase in spherical-like aberrations and better control over contrast sensitivity.


Asunto(s)
Sustancia Propia/cirugía , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Adolescente , Adulto , Algoritmos , Sensibilidad de Contraste/fisiología , Sustancia Propia/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Colgajos Quirúrgicos , Resultado del Tratamiento , Agudeza Visual/fisiología , Adulto Joven
17.
Arch Ophthalmol ; 127(7): 845-50, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19597102

RESUMEN

OBJECTIVE: To assess the long-term clinical outcomes of implantation of a lens consisting of a biocompatible collagen copolymer (Visian implantable Collamer lens [ICL]; STAAR Surgical, Nidau, Switzerland) for moderate to high myopia. METHODS: We evaluated 56 eyes of 34 patients with myopic refractive errors of -4.00 to -15.25 diopters (D) who underwent ICL implantation and routine postoperative examinations. Before and 1, 3, and 6 months and 1, 2, and 4 years after surgery, we assessed the safety, efficacy, predictability, stability, and adverse events of the surgery. RESULTS: Mean (SD) logMAR uncorrected and best spectacle-corrected visual acuities were -0.03 (0.23) and -0.21 (0.09), respectively, at 4 years after surgery. The mean (SD) safety and efficacy indexes were 1.19 (0.25) and 0.83 (0.29), respectively. At 4 years, 44 (79%) and 52 (93%) of the eyes were within +/-0.5 and +/-1.0 D, respectively, of the targeted correction. Mean (SD) manifest refraction changes of -0.24 (0.57) D occurred from 1 month to 4 years after surgery. No vision-threatening complications occurred during the observation period. CONCLUSION: Implantation of ICLs is safe and effective and provides predictable and stable refractive results in the treatment of moderate to high myopia during a 4-year observation period, suggesting its viability as a surgical option for the treatment of such eyes.


Asunto(s)
Implantación de Lentes Intraoculares , Miopía Degenerativa/cirugía , Lentes Intraoculares Fáquicas , Adulto , Materiales Biocompatibles , Recuento de Células , Endotelio Corneal/patología , Femenino , Estudios de Seguimiento , Humanos , Presión Intraocular/fisiología , Complicaciones Intraoperatorias , Iridectomía , Iris/cirugía , Láseres de Estado Sólido/uso terapéutico , Masculino , Persona de Mediana Edad , Miopía Degenerativa/fisiopatología , Complicaciones Posoperatorias , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual/fisiología
18.
J Refract Surg ; 25(3): 259-64, 2009 03.
Artículo en Inglés | MEDLINE | ID: mdl-19370820

RESUMEN

PURPOSE: To evaluate the vaulting of the STAAR Implantable Collamer Lens (ICL) over the crystalline lens after implantation. METHODS: One hundred twenty-three eyes of 68 patients with myopic refractive errors of -3.25 to -22.75 diopters undergoing ICL implantation were examined retrospectively. The magnitude of the central vaulting of the ICL was assessed quantitatively using slit-lamp microscopy at 3 months after surgery. Multiple regression analysis was used to assess the factors affecting the amount of vaulting. RESULTS: The mean central vaulting 3 months after surgery was 603.6 +/- 259.6 microm. Explanatory variables relevant to the vaulting were, in order of influence, the horizontal white-to-white distance (partial regression coefficient B = 0.268, P = .0002) and patient age (B = -0.007, P = .011). CONCLUSIONS: Although the majority of the variance remains unexplained, younger patients' eyes and eyes with greater white-to-white distances are more predisposed to have higher ICL vaulting over the crystalline lens.


Asunto(s)
Enfermedades del Cristalino/etiología , Implantación de Lentes Intraoculares/efectos adversos , Cristalino/patología , Lentes Intraoculares Fáquicas , Complicaciones Posoperatorias , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miopía Degenerativa/cirugía , Estudios Retrospectivos , Factores de Riesgo , Adherencias Tisulares/etiología
19.
Am J Ophthalmol ; 148(1): 164-70.e1, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19375059

RESUMEN

PURPOSE: To compare postoperative visual function after implantable collamer lens (ICL; STAAR Surgical, Nidau, Switzerland) implantation and after wavefront-guided laser in situ keratomileusis (WFG-LASIK) in eyes with high myopia. DESIGN: Retrospective, observational case study. METHODS: We investigated 46 eyes of 33 patients undergoing ICL implantation and 47 eyes of 29 patients undergoing WFG-LASIK (Technolas217z; Bausch & Lomb, Rochester, New York, USA) for the correction of high myopia (manifest spherical equivalent < or = -6 diopters). Ocular higher-order aberrations (HOA) and contrast sensitivity (CS) function were measured by Hartmann-Shack aberrometry (KR-9000; Topcon, Tokyo, Japan) and a CS unit (VCTS-6500; Vistech Consultants Inc, Dayton, Ohio, USA) before and 3 months after surgery, respectively. From the CS, the area under the log CS function (AULCSF) was calculated. RESULTS: For a 4-mm pupil, the changes in ocular coma-like aberrations, spherical-like aberrations, and total HOAs after ICL implantation were significantly less than those after WFG-LASIK (P < .001, Mann-Whitney U test). The postoperative AULCSF was significantly increased after ICL implantation (P < .001), whereas after WFG-LASIK, it was significantly decreased (P < .001). CONCLUSIONS: ICL implantation induces significantly fewer ocular HOAs than WFG-LASIK. Moreover, CS was improved significantly after ICL implantation, but deteriorated after WFG-LASIK in eyes with high myopia. Thus, in the correction of high myopia, ICL implantation seems to be superior in visual performance to WFG-LASIK, suggesting that it may be a better surgical option for the treatment of such eyes.


Asunto(s)
Queratomileusis por Láser In Situ/métodos , Implantación de Lentes Intraoculares , Miopía Degenerativa/cirugía , Lentes Intraoculares Fáquicas , Agudeza Visual/fisiología , Adolescente , Adulto , Sensibilidad de Contraste/fisiología , Topografía de la Córnea , Femenino , Humanos , Láseres de Excímeros/uso terapéutico , Masculino , Persona de Mediana Edad , Refracción Ocular/fisiología , Estudios Retrospectivos , Adulto Joven
20.
J Cataract Refract Surg ; 34(10): 1687-93, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18812119

RESUMEN

PURPOSE: To compare the postoperative visual outcomes after implantation of a Collamer toric implantable contact lens (ICL) and after wavefront-guided laser in situ keratomileusis in high myopic astigmatism. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. METHODS: This study comprised 30 eyes (18 patients) having toric ICL implantation and 24 eyes (17 patients) having wavefront-guided LASIK (Technolas 217z) to correct high myopic astigmatism (manifest spherical equivalent [SE] or=1.0 D). The safety, efficacy, predictability, stability, and adverse events were assessed preoperatively and 1 week and 1, 3, and 6 months postoperatively. RESULTS: At 6 months, the mean safety index was 1.28+/-0.25 (SD) in the ICL group and 1.01+/-0.16 in the LASIK group and the mean efficacy index, 0.87+/-0.15 and 0.83+/-0.23, respectively. All eyes in the ICL group and 71% of eyes in the LASIK group were within +/-1.00 D of the targeted SE correction at 6 months. The mean change in manifest refraction from 1 week to 6 months was -0.04+/-0.24 D in the ICL group and -0.60+/-0.49 D in the LASIK group. There were no significant complications in the ICL group; 2 eyes (8.3%) in the LASIK group required enhancement ablations. CONCLUSION: Toric ICL implantation was better than wavefront-guided LASIK in eyes with high myopic astigmatism in almost all measures of safety, efficacy, predictability, and stability, suggesting that toric ICL implantation may become a viable surgical option to treat high myopic astigmatism.


Asunto(s)
Astigmatismo/cirugía , Lentes de Contacto , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Implantación de Lentes Intraoculares/métodos , Miopía Degenerativa/cirugía , Adulto , Topografía de la Córnea , Femenino , Humanos , Complicaciones Intraoperatorias , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Resultado del Tratamiento , Agudeza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA