Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Radiol Case Rep ; 19(5): 1708-1711, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38384705

RESUMEN

Epipericardial fat necrosis (EFN) is a rare benign cause of chest pain, that is frequently overlooked. EFN involves the necrosis of fat tissue in the mediastinum, and presents on computed tomography (CT) as an ovoid lesion of fat attenuation surrounded by a rim of soft tissue attenuation. This case report describes a case of a 50-year-old man diagnosed with EFN on cardiac CT, which was incidentally associated with apical hypertrophic myocardiopathy. Notably, the detection of EFN proved difficult on arterial phase images during coronary CT angiography, whereas it was much easier to detect on delayed phase images. EFN should be considered in the differential diagnosis of chest pain, and careful examination of mediastinal fat is crucial for accurate diagnosis.

2.
Magn Reson Med Sci ; 2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37766549

RESUMEN

PURPOSE: The purposes of this study were to compare global coronary flow reserve (CFR) between patients with idiopathic dilated cardiomyopathy (DCM) and risk-matched controls using cardiac MRI (CMR), and to evaluate the relationship between global CFR and CMR left ventricular (LV) parameters. METHODS: Twenty-six patients with DCM and 26 risk-matched controls who underwent comprehensive CMR examination, including stress-rest coronary sinus flow measurement by phase contrast (PC) cine CMR were retrospectively studied. LV peak global longitudinal, radial, and circumferential strains (GLS, GRS, and GCS) were determined by feature tracking. RESULTS: Patients with DCM had significantly lower global CFR compared with the risk-matched controls (2.87 ± 0.86 vs. 4.03 ± 1.47, P = 0.001). Among the parameters, univariate linear regression analyses revealed significant correlation of global CFR with LV end-diastolic volume index (r = -0.396, P = 0.045), LV mass index (r = -0.461, P = 0.018), GLS (r = -0.558, P = 0.003), and GRS (r = 0.392, P = 0.047). Multiple linear regression analysis revealed GLS as the only independent predictor of global CFR (standardized ß = -0.558, P = 0.003). CONCLUSION: Global CFR was significantly impaired in patients with idiopathic DCM and independently associated with LV GLS, suggesting that microvascular dysfunction may contribute to deterioration of LV function in patients with idiopathic DCM.

3.
Jpn J Radiol ; 41(6): 596-604, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36607549

RESUMEN

PURPOSE: Several effective radiation dose reduction methods have been developed for coronary computed tomography angiography (CTA); however, their use in daily clinical practice remains unknown. We aimed to investigate radiation exposure and the utilization of dose-saving strategies for coronary CTA in hospitals in Mie Prefecture, Japan. MATERIALS AND METHODS: Image acquisition details and dose reports of 30 consecutive cardiac CT examinations performed in 2021 were obtained from 18 hospitals. The inclusion criteria were patients aged 20-80 years who weighed 50-70 kg and underwent coronary CTA using ≥ 64-row multidetector CT. The doses for the overall cardiac CT examination and coronary CTA were analyzed using the dose-length product (DLP) and CT dose index (CTDIvol), respectively. Multivariate analysis was performed to determine independent predictors that affect the radiation dose in coronary CTA. RESULTS: The median DLP of cardiac CT was 774 (interquartile range [IQR]: 538-1119) mGy*cm, and the median CTDIvol of coronary CTA was 33 (IQR: 25-48) mGy. The 75th percentile values of DLP for cardiac CT and that of CTDIvol for coronary CTA were slightly lower than the values recorded in the Japan Diagnostic Reference Level (DRLs) 2020 report (1285 mGy*cm and 66.4 mGy, respectively) but were substantially higher than those reported in a previous large international dose survey (402 mGy*cm and 24 mGy, respectively). Iterative reconstruction was performed during all examinations. Only six hospitals (33%) used a low tube potential (≤ 100 kVp), and nine hospitals (50%) used electrocardiogram-triggered prospective scanning. Multivariate analysis revealed low heart rate, low tube potential, and use of electrocardiogram-triggered prospective scanning as independent predictors of CTDIvol ≤ 24 mGy (p < 0.001, respectively). CONCLUSION: As of 2021, low tube potential and prospective scanning are underutilized, whereas iterative reconstruction is used in every coronary CTA in Mie Prefecture. Further efforts to optimize the radiation exposure from cardiac CT scans are necessary.


Asunto(s)
Angiografía por Tomografía Computarizada , Exposición a la Radiación , Humanos , Estudios Prospectivos , Dosis de Radiación , Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada Multidetector
4.
Magn Reson Med Sci ; 2022 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-36517009

RESUMEN

PURPOSE: Pulmonary emphysema may associate with ischemic heart disease through systemic microvascular abnormality as a common pathway. Stress cardiovascular MR (CMR) allows for the assessment of global coronary flow reserve (CFR). The purpose of this study was to evaluate the association between the emphysema severity and the multiple MRI parameters in the emphysema patients with known or suspected coronary artery disease (CAD). METHODS: A total of 210 patients with known or suspected CAD who underwent both 3.0T CMR including cine CMR, stress and rest perfusion CMR, stress and rest phase-contrast (PC) cine CMR of coronary sinus, and late gadolinium enhancement (LGE) CMR, and lung CT within 6 months were studied. Global CFR, volumes and functions of both ventricles and atria, and presence or absence of myocardial ischemia and infarction were evaluated. Emphysema severity was visually determined on lung CT by Goddard method. RESULT: Seventy nine (71.0 ± 7.9 years, 75 male) of 210 patients with known or suspected CAD had emphysema on lung CT. Goddard score was significantly correlated with CFR (r = -0.246, P = 0.029), left ventricular end-diastolic volume index (LV EDVI) (r = -0.230, P = 0.041), right ventricular systolic volume index (RV SVI) (r = -0.280, P = 0.012), left atrial (LA) total emptying volume index (r = -0.269, P = 0.017), LA passive emptying volume index (r = -0.309, P = 0.006), LA systolic strain (Es) (r = -0.244, P = 0.030), and LA conduit strain (Ee) (r = -0.285, P = 0.011) in the patients with emphysema. Multiple linear regression analysis revealed LA conduit function was independently associated with emphysema severity as determined by Goddard method (beta = -0.361, P = 0.006). CONCLUSION: LA conduit function independently associates with emphysema severity in the emphysema patients with known or suspected CAD after adjusting age, sex, smoking, and the CMR indexes including CFR. These findings suggest that impairment of LA function predominantly occurs prior to the reduction of the CFR in the emphysema patients with known or suspected CAD.

5.
Physiol Rep ; 9(22): e15123, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34806340

RESUMEN

BACKGROUND: Atrial fibrillation (AF) patients without coronary artery stenosis often show clinical evidence of ischemia. However myocardial perfusion in AF patients has been poorly studied. The purposes of this study were to investigate altered hyperemic myocardial blood flow (MBF) in patients with AF compared with risk-matched controls in sinus rhythm (SR), and to evaluate hyperemic MBF before and after catheter ablation using dynamic CT perfusion. METHODS: Hyperemic MBF was quantified in 87 patients with AF (44 paroxysmal, 43 persistent) scheduled for catheter ablation using dynamic CT perfusion, and compared with hyperemic MBF in 87 risk-matched controls in SR. Follow-up CT after ablation was performed in 49 AF patients. RESULTS: Prior to ablation, hyperemic MBF of patients in AF during the CT (1.29 ± 0.34 ml/mg/min) was significantly lower than in patients in SR (1.49 ± 0.26 ml/g/min, p = 0.002) or matched controls (1.65 ± 0.32 ml/g/min, p < 0.001); no significant difference was seen between patients in SR during the CT and matched controls (vs. 1.50 ± 0.31 ml/g/min, p = 0.815). In patients in AF during the pre-ablation CT (n = 24), hyperemic MBF significantly increased after ablation from 1.30 ± 0.35 to 1.53 ± 0.17 ml/g/min (p = 0.004); whereas in patients in SR during the pre-ablation CT (n = 25), hyperemic MBF did not change significantly after ablation (from 1.46 ± 0.26 to 1.49 ± 0.27 ml/g/min, p = 0.499). CONCLUSION: In the current study using stress perfusion CT, hyperemic MBF in patients with AF during pre-ablation CT was significantly lower than that in risk-matched controls, and improved significantly after restoration of SR by catheter ablation, indicating that MBF abnormalities in AF patients are caused primarily by AF itself.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Hiperemia/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Estudios de Casos y Controles , Ablación por Catéter , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/etiología , Imagen de Perfusión Miocárdica , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA