Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Orthop Case Rep ; 14(8): 179-184, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39157490

RESUMEN

Introduction: Fractures in the upper thoracic spine pose technical challenges due to the transition from cervical to thoracic spine, often resulting in complete spinal cord injuries necessitating stabilization. Various posterior fixation techniques include Harrington rods, wired distraction rods, L-rods with sub-laminar wiring, and pedicle screw fixation. Luque pioneered sublaminar wiring (SLW), later enhanced by Dove's Hartshill system for superior biomechanical stability. This case underscores the efficacy of the Hartshill system in stabilizing upper thoracic fractures with severe cord injuries, offering a cost-effective alternative to pedicle screw fixation. Case Report: A 30-year-old female with polytrauma presented symptoms of lower limb paralysis, bladder and bowel dysfunction, and loss of sensation. Imaging showed a severe D4-D5 fracture with retrolisthesis and spinal cord compression, necessitating surgical stabilization using a Hartshill rectangle with SLW. Following surgery, early rehabilitation and physical therapy were initiated, demonstrating the effectiveness of proper fixation in facilitating early mobilization. Conclusion: The Hartshill rectangle, with SLW, offers enduring spinal stabilization for unstable thoracic fractures with spinal cord injuries, enabling early mobilization and reducing neurological risks. Its versatile application spans scoliosis corrections and trauma-related spinal stabilization, reflecting its widespread use in spinal surgery.

2.
J Orthop Case Rep ; 14(5): 36-41, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38784875

RESUMEN

Introduction: Low back pain persisting after spine surgery presents diagnostic and treatment complexities for spine surgeons. Failed back syndrome is a term usually used to characterize chronic back or leg pain following spine surgery. Research has indicated a range of persistent pain occurrences after spine surgery. The sacroiliac joint (SIJ) has been recognized as a potential source of pain for a long time but has not received sufficient attention in subsequent years. Dysfunctions in the SIJ can result in a spectrum of clinical conditions, such as low back pain and lower limb radiculopathy. Traditional treatment approaches for SIJ disorders often involve conservative measures such as physical therapy, medications, intra-articular injections, and surgical options. In the past decade, endoscopic SIJ ablation has emerged as a minimally invasive alternative for managing SIJ pain and dysfunction. This approach combines minimal invasiveness with precise targeting, potentially reducing morbidity and enabling quicker recovery compared to open surgical procedures. Case Report: A 60-year-old female patient with grade 2 L5-S1 lytic listhesis initially underwent lumbar interbody fusion to address chronic low back pain and radiculopathy, resulting in significant symptom resolution for a brief period. The patient experienced a resurgence of symptoms within a short duration that proved refractory to conventional medical management and interventional pain management procedures. Ultimately, the patient achieved sustained relief after undergoing endoscopic SIJ ablation. Conclusion: This case report highlights the importance of endoscopic SIJ ablation as an innovative treatment for recurrent lower limb radiculopathy. Focusing on the SIJ, often neglected in lumbar spine surgery, this minimally invasive procedure shows promise in alleviating symptoms and enhancing patient outcomes.

3.
Surg Neurol Int ; 15: 56, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38468674

RESUMEN

Background: Lumbar discal pseudocysts are uncommon complications that can arise following lumbar spine surgery. It manifests as a fluid-filled sac near the intervertebral disc, causing pain and discomfort. Understanding its causes, symptoms, and management is crucial for patients and healthcare professionals involved in postoperative spinal care. Case Description A: 35-year-old female developed a discal pseudocyst after undergoing laminectomy and discectomy for lumbar disc herniation. The patient presented with recurrent lower back pain, radiculopathy, and neurological deficit two months post-surgery. Imaging revealed a discal pseudo cyst causing compression of the traversing right L5 nerve root. Given the refractory nature of her symptoms, an endoscopic procedure was offered. Using the transforaminal endoscopic technique, the pseudo cyst was identified and removed, leading to immediate symptomatic relief. Conclusion: This article reports the rare occurrence of discal pseudocyst and highlights the use of endoscopic techniques in its surgical management. Surgeons should be aware of the minimally invasive techniques, as they can offer less morbidity, shorter recovery times, and reduced healthcare costs compared to traditional open surgery.

4.
J Orthop Case Rep ; 14(2): 23-28, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38420233

RESUMEN

Introduction: An uncommon medical disorder known as tumor-induced osteomalacia (TIO) is characterized by severe hypophosphatemia, renal phosphate wasting, and osteomalacia due to a tumor. TIO has recently been linked to a particular kind of tumor known as phosphaturic mesenchymal tumor (PMT). PMTs release phosphatonins, such as fibroblast growth factor-23 (FGF23), which elevates serum levels of FGF23, leading to phosphate wasting and osteomalacia. However, due to their infrequent occurrence and vague symptoms, such as bone pain, myopathies, arthralgias, fractures, and weakness, the diagnosis of PMTs is often delayed or misdiagnosed. In this case report, a rare case of PMT in the proximal femur resulted in TIO, and it highlights the long and difficult journey from symptom onset to correct diagnosis and successful surgical management. Case Report: A 51-year-old woman endured persistent joint pain, muscle weakness, and fatigue for 2 years. Despite having no known health issues, she suffered from hip pain that spreads to her knees and ankles, and tingling and paresthesia in her legs, making it difficult to bear weight. She underwent surgery to remove a parathyroid adenoma, but unfortunately, her symptoms returned. Her magnetic resonance imaging revealed a lesion in her proximal femur, which was promptly removed. The tissue examination results verified the identity of the tumor as a PMT. The patient's phosphorus levels returned to normal and after a year of follow-up, she was able to resume normal daily activities, bear weight on the affected limb and showed no signs of the tumor recurrence. Conclusion: Adult patients experiencing bone pain, progressive weakness, and multiple fractures with no family history of similar conditions should consider TIO as a potential cause. It is rare and often misdiagnosed and complete surgical removal of the tumor is the optimal treatment for TIO, resulting in the resolution of long-standing symptoms and biochemical abnormalities. Timely recognition, localization, and surgical removal of the tumor are crucial for symptom resolution and the restoration of normal bone mineralization.

5.
J Orthop Case Rep ; 14(2): 136-139, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38420246

RESUMEN

Introduction: The accidental breakage of an epidural catheter during placement or removal poses a rare but challenging situation in clinical practice. This case report presents the successful removal of a broken epidural catheter and highlights the management strategies employed. Case Report: A 41-year-old male patient underwent a planned orthopedic implant removal surgery under epidural anesthesia. During catheter removal, a portion of the catheter fractured and remained lodged within the epidural space. The patient experienced persistent pain and concern regarding the retained fragment, necessitating immediate intervention. A multidisciplinary team comprising an orthopedic surgeon, neurosurgeon, anesthesiologist, and radiologists collaborated to develop a tailored retrieval strategy. Magnetic resonance imaging aided in localizing the fractured catheter fragment. Using a standard midline posterior approach, the catheter was safely removed without any complications. Post-retrieval monitoring revealed no adverse events, and the patient reported resolution of pain and improved satisfaction. Conclusion: Retrieving a broken epidural catheter requires a systematic and individualized approach. This case report contributes to the existing literature by providing insights into managing this rare complication, highlighting the importance of a multidisciplinary team, appropriate imaging, and meticulous retrieval techniques to ensure patient safety and optimal outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA