1.
Clin Rheumatol ; 23(2): 163-5, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15045633

RESUMEN

A 67-year-old woman with a 15-year history of seropositive rheumatoid arthritis developed acute night pain in both shoulders. Examination revealed bilateral swelling and joint mobility impairment. Ultrasonography disclosed joint effusions which were hemorrhagic on aspiration. Radiographs showed the presence of a four-part fracture of both humeral heads. Bilateral humeral head fractures can occur spontaneously in patients with rheumatoid arthritis and osteoporosis. Repeated use of crutches could be a predisposing factor.


Asunto(s)
Artritis Reumatoide/complicaciones , Fracturas Espontáneas/complicaciones , Fracturas del Húmero/complicaciones , Absorciometría de Fotón , Artritis Reumatoide/metabolismo , Artritis Reumatoide/patología , Densidad Ósea , Femenino , Fracturas Espontáneas/diagnóstico por imagen , Humanos , Fracturas del Húmero/diagnóstico por imagen , Fracturas del Húmero/cirugía , Húmero/diagnóstico por imagen , Húmero/metabolismo , Persona de Mediana Edad , Osteoporosis Posmenopáusica/complicaciones , Osteoporosis Posmenopáusica/diagnóstico por imagen , Resultado del Tratamiento , Ultrasonografía
2.
Injury ; 24 Suppl 3: S48-55, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8168876

RESUMEN

The generation of intramedullary pressure during reaming of the femur was compared for two different reamer systems: the AO/ASIF universal reamer and the Gray flexible reamer system (Howmedica), while reaming in 9 oncologic patients undergoing prophylactic nailing of metastatic femora as indicated by impending fractures (unbroken femora). An intracranial fibre optic catheter pressure-monitoring device inserted through the distal supracondylar cortex was used to perform measurements. Preliminary data are presented. Maximum pressures of up to 450 mmHg were recorded during reaming with the smaller 9.0 and 9.5 mm theta reamers. Rapid penetration of the reamer in both proximal and distal metaphyses caused much higher pressures than reaming the cortex of the diaphysis. Speed of penetration and volume of the reaming shaft were found to be important parameters. No significant differences between maximal pressures generated by the two types of reamers could be observed.


Asunto(s)
Fracturas del Fémur/prevención & control , Fémur/cirugía , Fijación Intramedular de Fracturas/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Fémur/fisiopatología , Humanos , Masculino , Manometría/métodos , Persona de Mediana Edad , Presión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA