Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PLoS One ; 18(10): e0291593, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37862307

RESUMEN

Polysomnographic sleep architecture parameters are commonly used to diagnose or evaluate treatment of sleep disorders. Polysomnography (PSG) having practical constraints, the development of wearable devices and algorithms to monitor and stage sleep is rising. Beside pure validation studies, it is necessary for a clinician to ensure that the conclusions drawn with a new generation wearable sleep scoring device are consistent to the ones of gold standard PSG, leading to similar interpretation and diagnosis. This paper reports on the performance of Somno-Art Software for the detection of differences in sleep parameters between patients suffering from obstructive sleep apnea (OSA), insomniac or major depressive disorder (MDD) compared to healthy subjects. On 244 subjects (n = 26 healthy, n = 28 OSA, n = 66 insomniacs, n = 124 MDD), sleep staging was obtained from PSG and Somno-Art analysis on synchronized electrocardiogram and actimetry signals. Mixed model analysis of variance was performed for each sleep parameter. Possible differences in sleep parameters were further assessed with Mann-Whitney U-test between the healthy subjects and each pathology group. All sleep parameters, except N1+N2, showed significant differences between the healthy and the pathology group. No significant differences were observed between Somno-Art Software and PSG, except a 3.6±2.2 min overestimation of REM sleep. No significant interaction 'group'*'technology' was observed, suggesting that the differences in pathologies are independent of the technology used. Overall, comparable differences between healthy subjects and pathology groups were observed when using Somno-Art Software or polysomnography. Somno-Art proposes an interesting valid tool as an aid for diagnosis and treatment follow-up in ambulatory settings.


Asunto(s)
Trastorno Depresivo Mayor , Apnea Obstructiva del Sueño , Humanos , Polisomnografía , Sueño , Apnea Obstructiva del Sueño/diagnóstico , Programas Informáticos
2.
Sleep Med ; 96: 14-19, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35576829

RESUMEN

The visual scoring of gold standard polysomnography (PSG) is known to present inter- and intra-scorer variability. Previously, Somno-Art Software, a cardiac based sleep scoring algorithm, has been validated in comparison to 2 expert visual PSG scorers. The goal of this research is to evaluate the performances of the algorithm against a pool of scorers. Sixty PSG and actimetry recording nights, representative of clinical practice (healthy subjects and patients suffering from obstructive sleep apnea [OSA], insomnia or major depressive disorder), were scored by 5 different sleep scoring centers and by the Somno-Art Software. Intra-class correlation coefficient (ICC) and Wilcoxon Signed-Rank Test were calculated between each scorer and the average value of the 6 scorers, including Somno-Art Software. In addition, epoch-by-epoch agreement between scorers were analyzed. Somno-Art Software estimation of sleep efficiency, wake, N1+N2, N3 and REM sleep fit within the interscorer range for the full dataset and the subgroups, except for underestimating N3 sleep in OSA patients. Additionally, Somno-Art Software overestimated sleep latency compared to the average scoring for insomniacs (+4.7 ± 1.6min). On the full dataset, Somno-Art Software had good (0.75 < ICC<0.90) or excellent (ICC>0.90) ICC scores for all sleep parameters except N3 sleep (moderate score, 0.50 < ICC<0.75). For the 4-stages epoch-by-epoch agreement, Somno-Art Software was slightly below that of the visual scorers except for the healthy sub-group where an overlap was demonstrated. Somno-Art Software sleep scoring shows a good interscorer reliability in the range of the 5 visual polysomnography scorers.


Asunto(s)
Trastorno Depresivo Mayor , Apnea Obstructiva del Sueño , Humanos , Polisomnografía , Reproducibilidad de los Resultados , Apnea Obstructiva del Sueño/diagnóstico , Fases del Sueño , Programas Informáticos
3.
Sleep Adv ; 3(1): zpab019, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37193409

RESUMEN

Study Objectives: Integrated analysis of heart rate (electrocardiogram [ECG]) and body movements (actimetry) during sleep in healthy subjects have previously been shown to generate similar evaluation of sleep architecture and continuity with Somno-Art Software compared to polysomnography (PSG), the gold standard. However, the performance of this new approach of sleep staging has not yet been evaluated on patients with disturbed sleep. Methods: Sleep staging from 458 sleep recordings from multiple studies comprising healthy and patient population (obstructive sleep apnea [OSA], insomnia, major depressive disorder [MDD]) was obtained from PSG visual scoring using the American Academy of Sleep Medicine rules and from Somno-Art Software analysis on synchronized ECG and actimetry. Results: Inter-rater reliability (IRR), evaluated with 95% absolute agreement intra-class correlation coefficient, was rated as "excellent" (ICCAAAvg95% ≥ 0.75) or "good" (ICCAAAvg95% ≥ 0.60) for all sleep parameters assessed, except non-REM (NREM) and N3 sleep in healthy participants (ICCAAAvg95% = 0.43, ICCAAAvg95% = 0.56) and N3 sleep in OSA patients (ICCAAAvg95% = 0.59) rated as "fair" IRR. Overall sensitivity, specificity, accuracy, and Cohen's kappa coefficient of agreement (κ) on the entire sample were respectively of 93.3%, 69.5%, 87.8%, and 0.65 for wake/sleep classification and accuracy and κ were of 68.5% and 0.55 for W/N1+N2/N3/rapid eye movement (REM) classification. These performances were similar in healthy and patient population. Conclusions: The present results suggest that Somno-Art can be a valid sleep-staging tool in both healthy subjects and patients with OSA, insomnia, or MDD. It could complement existing non-attended techniques measuring sleep-related breathing patterns or be a useful alternative to laboratory-based PSG when this latter is not available.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA