Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 86(9): 095114, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26429487

RESUMEN

Improvements in the available flux at neutron sources are making it increasingly feasible to obtain refineable neutron diffraction data from samples smaller than 1 mm(3). The signal is typically too weak to introduce any further sample environment in the 30-50 mm diameter surrounding the sample (such as the walls of a pressure cell) due to the high ratio of background to sample signal, such that even longer count times fail to reveal reflections from the sample. Many neutron instruments incorporate collimators to reduce parasitic scattering from the instrument and from any surrounding material and larger pieces of sample environment, such as cryostats. However, conventional collimation is limited in the volume it can focus on due to difficulties in producing tightly spaced neutron-absorbing foils close to the sample and in integrating this into neutron instruments. Here we present the design of a novel compact 3D rapid-prototyped (or "printed") collimator which reduces these limitations and is shown to improve the ratio of signal to background, opening up the feasibility of using additional sample environment for neutron diffraction from small sample volumes. The compactness and ease of customisation of the design allows this concept to be integrated with existing sample environment and with designs that can be tailored to individual detector geometries without the need to alter the setup of the instrument. Results from online testing of a prototype collimator are presented. The proof of concept shows that there are many additional collimator designs which may be manufactured relatively inexpensively, with a broad range of customisation, and geometries otherwise impossible to manufacture by conventional techniques.

2.
PLoS One ; 10(3): e0120611, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25815751

RESUMEN

The nucleation and growth of crystalline ice during cooling, and further crystallization processes during re-warming are considered to be key processes determining the success of low temperature storage of biological objects, as used in medical, agricultural and nature conservation applications. To avoid these problems a method, termed vitrification, is being developed to inhibit ice formation by use of high concentration of cryoprotectants and ultra-rapid cooling, but this is only successful across a limited number of biological objects and in small volume applications. This study explores physical processes of ice crystal formation in a model cryoprotective solution used previously in trials on vitrification of complex biological systems, to improve our understanding of the process and identify limiting biophysical factors. Here we present results of neutron scattering experiments which show that even if ice crystal formation has been suppressed during quench cooling, the water molecules, mobilised during warming, can crystallise as detectable ice. The crystallisation happens right after melting of the glass phase formed during quench cooling, whilst the sample is still transiting deep cryogenic temperatures. We also observe strong water isotope effects on ice crystallisation processes in the cryoprotectant mixture. In the neutron scattering experiment with a fully protiated water component, we observe ready crystallisation occurring just after the glass melting transition. On the contrary with a fully deuteriated water component, the process of crystallisation is either completely or substantially supressed. This behaviour might be explained by nuclear quantum effects in water. The strong isotope effect, observed here, may play an important role in development of new cryopreservation strategies.


Asunto(s)
Crioprotectores/química , Cristalización , Deuterio/química , Hielo/análisis , Difracción de Neutrones/métodos , Congelación , Modelos Químicos , Teoría Cuántica , Dispersión del Ángulo Pequeño , Vitrificación
3.
Rev Sci Instrum ; 85(4): 043904, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24784623

RESUMEN

Pressure generation at cryogenic temperatures presents a problem for a wide array of experimental techniques, particularly neutron studies due to the volume of sample required. We present a novel, compact pressure cell with a large sample volume in which load is generated by a bellow. Using a supply of helium gas up to a pressure of 350 bar, a load of up to 78 kN is generated with leak-free operation. In addition, special fiber ports added to the cryogenic center stick allow for in situ pressure determination using the ruby pressure standard. Mechanical stability was assessed using finite element analysis and the dimensions of the cell have been optimized for use with standard cryogenic equipment. Load testing and on-line experiments using NaCl and BiNiO3 have been done at the WISH instrument of the ISIS pulsed neutron source to verify performance.

4.
Rev Sci Instrum ; 79(2 Pt 1): 026107, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315339

RESUMEN

A pressure cell (maximum working pressure of 100 bars) has been developed for neutron scattering experiments at ultralow temperatures (T<100 mK) which makes use of a Bridgman seal design more usually seen in higher temperature experiments in the kilobar range. The large volume of the cell ( approximately 18 cm3) and its construction from a high-strength aluminum alloy make it suitable for inelastic neutron scattering experiments. The cell has been proof tested in operando in search for the supersolid state of helium-4.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA