Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
2.
J Oral Rehabil ; 43(7): 481-7, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27027864

RESUMEN

Abnormal swallow patterns have been associated with specific dentofacial traits, such as an anterior open bite, but the cause-effect relationship between swallowing and malocclusion remains highly controversial. The aim of this research was to determine the effects of acute change in occlusal vertical dimension (OVD) on intraoral pressure swallow patterns and perioral electromyographic activity (EMG) during swallowing. Ten volunteers (five female, five male; 27-32 years) repeated standardised swallowing tasks as the OVD was progressively increased using mandibular trays of different heights. Standardised swallowing tasks were performed repetitively with each tray in place. Individual swallowing waveforms were quantitatively and qualitatively analysed. Peak pressure, swallow duration, time to peak pressure and lip EMG peak activity were assessed for each swallow. Data were analysed using mixed-model analysis. As OVD increased, lip peak pressure during swallowing increased almost threefold (+2·1 kPa; P ≤ 0·001), whereas swallow duration increased by 12·7 per cent (+160 ms; P = 0·01) at lip level and by 26·4 per cent (+270 ms; P < 0·001) at tongue level. Perioral muscle activity during swallows increased by 43·7 per cent (P ≤ 0·01) up to the OVD where resting lip seal was not attainable. Swallowing waveforms varied markedly between individuals, but interindividual waveforms were only minimally affected. The adaptive response and the waveform similarities associated with OVD variation supports the existence of a central control mechanism for swallowing, which may be modified by peripheral inputs.


Asunto(s)
Adaptación Fisiológica/fisiología , Deglución/fisiología , Electromiografía , Maloclusión/fisiopatología , Lengua/fisiología , Adulto , Electromiografía/métodos , Femenino , Voluntarios Sanos , Humanos , Masculino , Presión , Dimensión Vertical
3.
Int J Legal Med ; 130(4): 985-994, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26156450

RESUMEN

Few studies have examined the biomechanical basis for backspatter from cranial gunshot wounds. Backspatter is material which travels against the direction of fire following ejection from a gunshot entrance wound. Our paper focuses on the use of animals for reconstructing this phenomenon. Five live pigs and several slaughtered pigs were shot using either 9 × 19 mm, 115 grain, full metal jacketed ammunition or .22 long rifle, 40 grain, lead, round-nose ammunition. A high-speed camera was used to record the entrance wound formation and backspatter. A small amount of backspattered material was produced with all targets, and blood backspatter was seen in a few cases. However, we conclude that our model provides an understanding of the phenomenon of backspatter and the physical mechanisms associated with it. The various components of the mechanism of backspatter formation are complex and overlap. The principle mechanism observed in pig cranial gunshots was the high-speed impact response of the skin overlying the skull bone. This study has also produced evidence supporting the view that backspatter can result from the splashing of superficial blood if it is already present on the skin. Subcutaneous gas effects have been demonstrated for backspatter from contact shots. There has been no clear evidence of the role of the collapse of a temporary cavity within the brain.


Asunto(s)
Manchas de Sangre , Balística Forense , Traumatismos Penetrantes de la Cabeza/patología , Heridas por Arma de Fuego/patología , Animales , Armas de Fuego , Modelos Animales , Porcinos
4.
J Oral Rehabil ; 43(5): 356-63, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26666708

RESUMEN

To measure and compare the intraoral pH and temperature of individuals during sleep with and without mouth breathing. Ten healthy participants [mean age = 25·8 (± 4·3)] wore a custom-made appliance fitted with a pH probe and thermocouple for two sets of 48 h. Continuous pH and temperature measurements were taken from the palatal aspect of the upper central incisors. To simulate mouth breathing during sleep, participants wore a nose clip for two nights of the four, with the first group (n = 5) wearing the nose clip during the first night and the rest (n = 5) wearing the nose clip during the second night of sleep to balance any potential bias from the wearing sequence. Both qualitative and quantitative analyses were conducted. The mean intraoral pH during daytime was 7·3 (± 0·4) and during sleep was 7·0 (± 0·5). The mean intraoral pH during sleep with mouth breathing was 6·6 (± 0·5), which was statistically significant compared with the normal sleep condition (P < 0·01). The intraoral pH decreased slowly over the hours of sleep in all participants. When sleeping with forced mouth breathing, intraoral pH showed a greater fall over a longer period of time. The mean intraoral temperature was 33·1 °C (± 5·2) during daytime and 33·3 °C (± 6·1) during sleep, with no statistical significance between sleep with and without mouth breathing (P > 0·05). The results suggest that mouth breathing during sleep is related to a decrease in intraoral pH compared with normal breathing during sleep, and this has been proposed as a causal factor for dental erosion and caries.


Asunto(s)
Temperatura Corporal , Concentración de Iones de Hidrógeno , Monitoreo Fisiológico/instrumentación , Respiración por la Boca , Boca/fisiología , Sueño/fisiología , Adulto , Femenino , Voluntarios Sanos , Humanos , Boca/metabolismo , Hueso Paladar , Cooperación del Paciente , Síndromes de la Apnea del Sueño
5.
J Oral Rehabil ; 42(8): 563-70, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25809398

RESUMEN

To describe a novel approach for continuous measurement of intra-oral pH and temperature in individuals carrying out normal daily activities over 24 h. We designed, validated and constructed a custom-made appliance fitted with a pH probe and a thermocouple. Six subjects wore the appliance over a 24-h period for two non-consecutive days, while the intra-oral pH and temperature were measured continuously and recorded. Intra-oral pH and temperature were very similar across different recording days, the difference being not statistically significant (P ≥ 0.14). There was a noticeable difference in the pattern of variation of pH between day and night. During the day, the mean pH was 7.3 (±0.4) and dropped markedly only after consumption of acidic food and drinks. The intra-oral pH decreased slowly during sleep with an average pH of 6.6 (±0.4) being recorded. The difference between day and night was statistically significant (P = 0.002). The mean intra-oral temperature was 33.9 °C (±0.9) during daytime and 35·9 °C (±0·5) during sleep (P = 0.013) with minor fluctuations occurring over 24 h. The continuous and simultaneous intra-oral pH and temperature measurement system described in this report is reliable, easy to construct, able to measure variables over a sustained period and may serve as a future diagnostic tool in a number of applications.


Asunto(s)
Temperatura Corporal/fisiología , Monitoreo Fisiológico/instrumentación , Boca/fisiología , Relojes Circadianos/fisiología , Femenino , Humanos , Concentración de Iones de Hidrógeno , Proyectos Piloto
6.
J Oral Rehabil ; 41(4): 282-8, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24483937

RESUMEN

Pain resulting from the application of orthodontic forces varies markedly across individuals. The reasons of this variability are still largely unknown. To investigate factors that may be associated with orthodontic pain following the application of orthodontic separators. One hundred and seven participants were screened for pain response over 48 h following placement of orthodontic elastomeric separators. The highest (n = 10) and lowest (n = 10) pain responders were identified, and data collected on tooth pain sensitivity to electrical stimulation in conjunction with using the Pain Catastrophising Scale (PCS), Dental Anxiety Scale (DAS) and cold pressor test (CPT). There were statistically significant differences between high- and low-pain responders in catastrophising score (P ≤ 0.023). For every PCS magnification score of 1 unit higher, the relative risk of being a high-pain responder was 1.6 (P = 0.002); those scoring higher on helplessness had a lower risk of being so. DAS scores of high-pain responders were twice as high as those of low-pain responder (P = 0.043). During the first 2 min of CPT, the high-pain responders experienced more pain than the low-pain responders (P ≤ 0.029). Tooth pain thresholds did not differ between the two different pain responder groups. Pain catastrophising, dental anxiety and cold sensitivity appear to modify the pain experienced following placement of orthodontic separators. Further research is needed to determine the validity of screening questions to identify at-risk patients prior to commencing orthodontic treatment.


Asunto(s)
Elastómeros/efectos adversos , Aparatos Ortodóncicos/efectos adversos , Odontalgia/etiología , Adulto , Frío/efectos adversos , Estimulación Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Dimensión del Dolor/métodos , Factores de Riesgo , Adulto Joven
7.
Aust Dent J ; 59 Suppl 1: 155-61, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24152133

RESUMEN

Tongue pressure data taken from healthy subjects during normal oral activities such as mastication, speech and swallowing are providing us with new ways of understanding the role of the tongue in craniofacial growth and function. It has long been recognized that the sequential contact between the tongue and the palate plays a crucial role in the oropharyngeal phase of swallowing. However, because the focus of most research on intraoral pressure has been on the generation of positive pressure by the tongue on the hard palate and teeth, generation and coordination of absolute intraoral pressures and regional pressure gradients has remained unexplored. Ongoing research in our laboratory has uncovered highly variable individual pressure patterns during swallowing, which can nonetheless be divided into four stages: preparatory, primary propulsive, intermediate and terminal. These stages may further be sub-classified according to pressure patterns generated at the individual level as tipper or dipper patterns in the preparatory stage, roller or slapper in the primary propulsive and monophasic or biphasic during the intermediate stage. Interestingly, while an increase in bolus viscosity can result in significant changes to pressure patterns in some individuals, it has little effect in others. Highly individual responses to increased viscosity are also observed with swallowing duration. The above, together with other findings, have important implications for our understanding of the aetiology of widely differing conditions such as protrusive and retrusive malocclusions, dysphagia and sleep apnoea, as well as the development of novel food products.


Asunto(s)
Deglución/fisiología , Lengua/fisiología , Adulto , Femenino , Humanos , Incisivo/fisiología , Masculino , Mandíbula , Boca , Presión , Lengua/anatomía & histología
8.
Appl Ergon ; 45(3): 556-63, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23972454

RESUMEN

The aim of the present study was to assess the activity levels of the sternocleidomastoid muscle and upper trapezius muscle during static postures under controlled and standardized conditions, and to determine whether the muscle activity differed between sexes. Electromyographic (EMG) activity was recorded unilaterally from the sternocleidomastoid and upper trapezius muscle in 17 participants whilst they were performing various postural tasks. EMG amplitude was measured by the root mean square values of the raw signals and normalized to peak maximum contractile values for each muscle (%MVC). The intensity of muscle activity was ranked as light (<3%MVC), moderate (3%MVC ≤ EMG ≤ 8%MVC), and substantial (>8%MVC). During most tasks the two muscles contracted light to moderately. Head leaning and shoulder shrugging postures yielded substantial muscle activity in both muscles. Muscle activity did not differ significantly between male and female participants (F = 3.1; p = 0.078). Our findings provided normative values, which will enhance future studies of muscle activity during work in a natural, unrestrained environment.


Asunto(s)
Músculo Esquelético/fisiología , Músculos del Cuello/fisiología , Postura/fisiología , Hombro/fisiología , Trabajo/fisiología , Adulto , Electromiografía , Femenino , Humanos , Masculino , Movimiento/fisiología , Músculos Superficiales de la Espalda/fisiología , Adulto Joven
9.
J Mech Behav Biomed Mater ; 29: 385-92, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24184862

RESUMEN

Ballistic gelatin is frequently used as a model for soft biological tissues that experience projectile impact. In this paper we investigate the response of a number of gelatin materials to the penetration of spherical steel projectiles (7 to 11mm diameter) with a range of lower impacting velocities (<120m/s). The results of sphere penetration depth versus projectile velocity are found to be linear for all systems above a certain threshold velocity required for initiating penetration. The data for a specific material impacted with different diameter spheres were able to be condensed to a single curve when the penetration depth was normalised by the projectile diameter. When the results are compared with a number of predictive relationships available in the literature, it is found that over the range of projectiles and compositions used, the results fit a simple relationship that takes into account the projectile diameter, the threshold velocity for penetration into the gelatin and a value of the shear modulus of the gelatin estimated from the threshold velocity for penetration. The normalised depth is found to fit the elastic Froude number when this is modified to allow for a threshold impact velocity. The normalised penetration data are found to best fit this modified elastic Froude number with a slope of 1/2 instead of 1/3 as suggested by Akers and Belmonte (2006). Possible explanations for this difference are discussed.


Asunto(s)
Gelatina , Ensayo de Materiales/métodos , Fenómenos Mecánicos , Ensayo de Materiales/instrumentación
10.
J R Army Med Corps ; 159(4): 294-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24109096

RESUMEN

INTRODUCTION: Indirect ballistic fractures occur when a projectile passes close to, but not contacting, the bone. The mechanism of how these fractures occur is not yet proven, but recently the acoustic shockwave has been excluded as a cause. The objective of this study is to determine whether the expanding temporary cavity, the collapse of this cavity or its oscillation causes these fractures. In addition, we describe the fracture morphology and biomechanical causes of this injury. METHOD: 40 fresh deer femora were strain gauged and embedded in ballistic gelatin before being shot with four different projectiles with varying distances off the bone. Pressure recordings, chronographs and radar allowed assessment of local pressures and energy transfer. High-speed video allowed the temporal relationship between the temporary cavity and fracture formation to be analysed, while sample dissection allowed the fracture morphology to be described. RESULTS: The fractures produced were consistently wedge-shaped and caused by the expansion of the temporary cavity, flexing the bone beyond its yield point, causing tension failure on the cortex opposite the expanding temporary cavity and a compression wedge on the side of the cavity. Local pressure was not predictive of fracture formation but the energy transfer to the gelatin block was predictive. CONCLUSIONS: Indirect fractures are caused by the expansion of the temporary cavity and relate to the proximity of this cavity to the bone. Fractures occur from flexion of the bone and classically display wedge-shaped fracture patterns with the apex of the wedge pointing away from the expanding cavity.


Asunto(s)
Fracturas del Fémur , Heridas por Arma de Fuego , Transferencia de Energía , Fémur , Presión
11.
Int J Legal Med ; 127(5): 951-5, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23740475

RESUMEN

OBJECTIVE: To assess the usefulness of scanning electron microscopy and energy dispersive x-ray spectroscopy in matching bullet wipe to the bullet. HYPOTHESIS: Bullet wipe can be used to match a bullet type to a crime scene.


Asunto(s)
Balística Forense/métodos , Humanos , Microscopía Electrónica de Rastreo , Variaciones Dependientes del Observador , Papel , Distribución Aleatoria , Espectrometría por Rayos X
12.
J Electromyogr Kinesiol ; 23(3): 600-7, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23422325

RESUMEN

Work related musculoskeletal disorders (WMSDs) are common among dentists and possibly caused by prolonged static load. The aim of this study was to assess the contraction pattern of neck and shoulder muscles of orthodontists in natural environments. Electromyographic (EMG) activity of right sternocleidomastoid and trapezius muscles were recorded by means of portable recorders in eight orthodontists during working conditions, and both active and resting non-working conditions. Recordings were analysed in terms of contraction episode (CE) count, amplitude, and duration. The sternocleidomastoid and trapezius muscles contracted about 40-70times per hour in the natural environment. Their EMG activity pattern mainly consisted of short-lasting, low-amplitude CEs. The counts and amplitude of sternocleidomastoid CEs did not differ across vocational and non-vocational conditions. The number and amplitude of trapezius CEs were slightly but significantly higher during the vocational condition. There were highly significant (p<0.001) differences in duration of CEs across conditions, with two to threefold increase in the average duration of trapezius muscle contractions found in the vocational setting. During orthodontic work, operators commonly hold muscular contractions for significantly longer periods than are encountered in non-vocational settings. This behaviour may be associated causally with the increases seen in WMSDs through proposed pathophysiological mechanisms occurring at the motor unit level. Our findings may also be valid for other occupations characterised by seated static postures with precision hand and wrist movements.


Asunto(s)
Odontólogos , Electromiografía , Músculo Esquelético/fisiología , Músculos del Cuello/fisiología , Hombro/fisiología , Carga de Trabajo , Adulto , Femenino , Humanos , Masculino , Contracción Muscular/fisiología , Ortodoncia
13.
N Z Dent J ; 109(4): 142-7, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24396953

RESUMEN

OBJECTIVES: To describe patterns and trends in facial fractures in New Zealand over a decade. METHOD: A secondary analysis of Ministry of Health data on facial fractures occurring between 30 June 1999 and 1 July 2009. Patient demographic characteristics and the details of injury were analysed and described. RESULTS: Over the study period, the incidence of injury was constant. A total of 26,637 facial fractures were recorded. Most (79%) occurred in males, giving a male-to-female ratio of 4:1. Peak injury rates for both males and females, coincide with the legal alcohol purchasing age. Interpersonal violence (IPV) was the leading cause of facial fractures, accounting for 38%; it increased steadily each year. The number of fractures attributed to sports/other, and road traffic accidents (RTA) had fallen. Maori still continue to experience a disproportionate rate of facial fractures, twice that of the NZ European population. CONCLUSIONS: Interpersonal violence is an increasing problem in NZ and contributes to a greater number of facial fractures each year. More measures are required to reduce the number of IPV-related injuries. Perhaps the most effective would be to return the legal alcohol purchasing age to 20 years. More is also required to reduce facial fractures in the high-risk injury groups of young adults, males, and Maori.


Asunto(s)
Huesos Faciales/lesiones , Fracturas Craneales/epidemiología , Accidentes de Tránsito/estadística & datos numéricos , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Consumo de Bebidas Alcohólicas/epidemiología , Pueblo Asiatico/estadística & datos numéricos , Traumatismos en Atletas/epidemiología , Niño , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Nativos de Hawái y Otras Islas del Pacífico/estadística & datos numéricos , Nueva Zelanda/epidemiología , Factores Sexuales , Violencia/estadística & datos numéricos , Población Blanca/estadística & datos numéricos , Adulto Joven
14.
Forensic Sci Int ; 217(1-3): 93-100, 2012 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-22080000

RESUMEN

In Dunedin (South Island, New Zealand), a sexual assault is reported to police approximately once every two to three weeks, with some reports fictitious. Identifying a fictitious claim is difficult, and damage to apparel, especially knickers, may be the only form of evidence. In this paper, the tear behaviour of three knit fabrics, typical of those used to manufacture knickers is reported: the effect of laundering prior to tearing was considered. Tearing behaviour was determined using an Instron universal testing machine (Model 4464) operating in tensile mode to eliminate variability which is inevitable with human participants. Cotton and cotton-rich fabrics were more difficult to tear than modal-rich fabrics: the addition of elastane increased the time for the tear initiation as elastane fibres allowed the fabric to extend more before breaking. Specimens behaved differently depending on which direction they were torn (course-direction specimens down the length of the specimen, wale-direction specimens 50% down the length, 50% across the specimen). Laundered fabrics required less force to tear than new fabrics, therefore, when examining torn apparel, the fibre content and age of the garment need to be considered. Torn fibre ends appeared similar to those damaged by other means (e.g. knife, screwdriver) and no features visible under FESEM could be attributed solely to tearing damage in the fabrics studied.

15.
J Dent Res ; 90(10): 1206-10, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21810620

RESUMEN

UNLABELLED: The aim of this observational study was to investigate the features of the chewing activity and the variability of the human chewing pace, as assessed in the natural environment. It was hypothesized that the chewing pace is relatively constant within individuals across different days but is variable across individuals. Electromyographic surface activity was recorded unilaterally from the masseter in 21 participants for 3 hours over 3 recording days, in the natural environment, by means of portable recorders. The time-frequency properties of chewing activity were assessed with a previously validated algorithm. Repeated-measurements ANOVA was used for statistical analysis. Chewing activity mainly occurred in the range of 0.94 Hz (5(th) percentile) and 2.17 Hz (95(th) percentile). Mean and median chewing frequencies were 1.57 Hz and 1.58 Hz, respectively (95% confidence intervals: 1.45-1.68 Hz). The mean duration of chewing episodes was 13.0 sec, the 5(th) and 95(th) percentiles being 2.7 sec and 34.9 sec, respectively. Variability of the mean chewing frequency between individuals was much greater than that within individuals (F = 29.8; p < 0.001). The individual chewing paces were stable across different days (intraclass correlation coefficient = 0.88; 95% confidence intervals = 0.79-0.94). Our findings provide evidence that each individual, in the natural environment, chews with a consistent pace across different days. ABBREVIATIONS: ANOVA, analysis of variance; CPG, central pattern generator; EMG, electromyography; ICC, Intra-class Correlation coefficient; SD, standard deviation.


Asunto(s)
Músculo Masetero/fisiología , Masticación/fisiología , Adulto , Algoritmos , Análisis de Varianza , Electromiografía , Femenino , Análisis de Fourier , Humanos , Masculino , Observación , Estadística como Asunto , Factores de Tiempo
16.
N Z Dent J ; 107(2): 44-50, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21721336

RESUMEN

OBJECTIVE: The evolution of dental tissues in relation to tooth function is poorly understood in non-mammalian vertebrates. We studied the dentition of Sphenodon punctatus, the sole remaining member of the order Rhynchocephalia in this light. METHODS: We examined 6 anterior maxillary caniniform teeth from adult Sphenodon by scanning electron microscopy, nano-indentation and Raman spectroscopy. RESULTS: The elastic modulus (E) for tuatara enamel was 73.17 (sd, 3.25) GPa and 19.52 +/- 0.76 Gpa for dentine. Hardness (H) values for enamel and dentine were 4.00 (sd, 0.22) and 0.63 +/- 0.02 Gpa respectively. The enamel was thin (100 gm or less), prismless and consisted of grouped parallel crystallites. Incremental lines occurred at intervals of about 0.5 to 1 rm. There were tubular structures along the enamel dentine junction running from the dentine into the inner enamel, at different angles. These were widened at their base with a smooth, possibly inorganic lining. Enamel elastic modulus and hardness were lower than those for mammals. CONCLUSIONS: The presence of enamel tubules in the basal part of the enamel along the EDJ remains speculative, with possible functions being added enamel/dentinal adhesion or a role in mechanosensation.


Asunto(s)
Esmalte Dental/anatomía & histología , Esmalte Dental/química , Reptiles , Animales , Esmalte Dental/ultraestructura , Módulo de Elasticidad , Dureza , Microscopía Electrónica de Rastreo , Espectrometría Raman
17.
Forensic Sci Int ; 197(1-3): 21-9, 2010 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-20071112

RESUMEN

Blunt force assault is a growing issue worldwide. In New Zealand, recorded cases of grievous blunt force assault increased steadily from 1011 in 1999 to 2139 in 2008. In many cases of blunt force assault victims are struck on parts of their body covered by clothing, yet the use of damage to apparel as forensic evidence largely appears to have been overlooked. The current research investigated blunt force impact (BFI) damage in common apparel fabrics and the effects prior and post-laundering had on this damage. Two 100% cotton fabrics (single jersey knit, bull drill) were impacted as single and double layers using an impactor representative of a hammer face, the force transmitted through specimens was measured and impulse calculated. Impacting and laundering were completed cumulatively to establish the effects of impact damage on new, dimensionally stable (laundered 6 times) and aged fabrics (laundered up to 30 times), and the effects of laundering on impacted specimens. BFI left recognisable patterns of damage in specimens, although the extent of this damage varied. Laundering after the impact event altered the visible and microscopic damage. Laundering previously impacted fabrics produced holes in some specimens and some fibres exhibited failure characteristic of blunt force impact.

18.
Front Oral Biol ; 13: 80-85, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19828975

RESUMEN

The Tuatara, Sphenodon, is a small reptile currently restricted to islands off the coast of New Zealand where it feeds mainly on arthropods. A widely held misconception is that 'Sphenodon does not have real teeth' and instead possesses 'serrations on the jaw bone'. One hatchling and one adult dentary were examined under SEM. Two longitudinal ground sections 100-microm thick were prepared through a lower canine tooth and its supporting tissues. There was clear evidence of aprismatic enamel (primless enamel) containing dentine tubules crossing the EDJ, dentine, cementum and a basal-bone attachment. Enamel increments averaged approximately 3 microm/day and extension rates were approximately 30 microm/day. The base of the tooth consisted of basal attachment bone that graded from few cell inclusions to lamella or even Haversian-like bone with evidence of remodeling. A string of sclerosed pulp-stone like structures filled the pulp chamber and were continuous with the bone of attachment. Bone beneath the large central nutrient mandibular (Meckel's) canal was quite unlike lamella bone and appeared to be fast growing and to contain wide alternating cell-rich and cell-free zones. Bone cells were rounded (never fusiform) and had few, if any, canaliculi. The dentine close to the EDJ formed at about the same rate as enamel but also contained longer period increments approximately 100 microm apart. These were spaced appropriately for monthly lunar growth bands, which would explain the basis of the banding pattern observed in the fast growing basal bone beneath the Meckel's canal.


Asunto(s)
Proceso Alveolar/ultraestructura , Diente Canino/ultraestructura , Mandíbula/ultraestructura , Reptiles/anatomía & histología , Animales , Cemento Dental/ultraestructura , Esmalte Dental/ultraestructura , Dentina/ultraestructura
19.
Forensic Sci Int ; 191(1-3): 86-96, 2009 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-19646831

RESUMEN

Stab injuries and fatalities have been reported to be the most common crimes of violence in several countries, particularly in those where access to firearms is restricted [J.M. Taupin, F.-P. Adolf, J. Robertson, Examination of damage to textiles, in: J. Robertson, M. Grieve (Eds.), Forensic Examination of Fibres, CRC Press, United States of America, 1999, pp. 65-87; A.C. Hunt, R.J. Cowling, Murder by stabbing, Forensic Sci. Int. 52 (1991) 107-112; D.A. Rouse, Patterns of stab wounds: a six year study, Med. Sci. Law 34 (1994) 67-71]. Analysis of damaged apparel may provide important information about the cause of death and the events leading up to and after the victim's final moments [M.T. Pailthorpe, N.A.G. Johnson, The private forensic scientist and the criminal justice system, in: D. Biles, J. Vernon (Eds.), Private Sector and Community Involvement in the Criminal Justice System: Conference Proceedings, vol. 23, Australian Institute of Criminology, Wellington, 1994, 231-240]. A high proportion of stab wounds occur in the chest and as this area is generally clothed many sharp force cases involve damage to fabrics [J.M. Taupin, F.-P. Adolf, J. Robertson, Examination of damage to textiles, in: J. Robertson, M. Grieve (Eds.), Forensic Examination of Fibres, CRC Press, United States of America, 1999, pp. 65-87; A.C. Hunt, R.J. Cowling, Murder by stabbing, Forensic Sci. Int. 52 (1991) 107-112; D.A. Rouse, Patterns of stab wounds: a six year study, Med. Sci. Law 34 (1994) 67-71]. The structural stabilisation and degradation of fabric due to laundering significantly alters fabric properties [S.E. Gore, R.M. Laing, C.A. Wilson, D.J. Carr, B.E. Niven, Standardizing a pre-treatment cleaning procedure and effects of application on apparel fabrics, Text. Res. J. 76 (2006) 455-464], yet the effect of such on severance morphology does not appear to have been investigated. In this work the effect of blade type (hunting knife, kitchen knife, screwdriver) on new and laundered apparel fabrics was investigated. Two approaches were used (i) a human participant trial, and (ii) guided drop testing (using an impact rig). Force-time plots from the human participant trials were matched to those from the impact rig. Information on severance morphology was obtained using visual analysis techniques. Blades could be differentiated and directionality estimated by observing differences in severance shape and size, the degree of fabric distortion, the position of severed yarn ends, loop snippets, curled yarns, planar array and the morphology of fractured fibres. Fabric construction had a visible effect on severance morphology. Pre-impact degradation via laundering hindered the ability to link fractured fibre ends to a source of damage by altering morphology and increasing the variability. The correlation between blade height and severance length was weak, attributed to elastic deformation and recovery. The impact rig was a valuable tool in the reconstruction of textile damage. Damage was consistent when inflicted using a human participant trial and the impact rig, although more variable in the former. The advantage of the impact rig lies in the ability to produce a severance typical of the blade in question, under controlled conditions, in a reproducible manner.


Asunto(s)
Fibra de Algodón , Modelos Biológicos , Heridas Punzantes/patología , Adulto , Medicina Legal , Humanos , Lavandería , Masculino , Microscopía , Fotograbar , Armas
20.
J Forensic Odontostomatol ; 27(1): 33-6, 2009 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-22717957

RESUMEN

UNLABELLED: This paper investigates the changes in upper and lower dental bite records that occur when the anterior teeth occlude into a three-dimensional rather than a flat object. METHODS: anterior bite registrations were obtained from 20 volunteers with full and unrestored dentitions. As a three- dimensional, life-like bite target we cast a silicone replica from the impression of an actual arm, fitted with a rigid bony interior. Each participant was asked to bite into a single layer of softened bite registration wax wrapped around the same location on the fake arm, as well as into a flat wafer of the same material. Upper and lower bite registrations were then scanned in the same location on a flat bed scanner. We analysed the sizes of the different bite marks by means of landmark- and semi-landmark analysis to calculate Procrustes distances between tooth outlines. In order to analyse shape variation between the two types of bite registration we carried out principal components analyses on the partial warp scores. These were derived from partial Procrustes coordinates aligned by means of thin-plate spline decomposition based on a bending energy matrix. Our results show that there are significant differences in the shape of the upper or lower teeth when they occlude into a flat or three- dimensional target. We conclude that the use of a traditional flat bite registration in human bitemark reconstruction and analysis has to be seriously questioned.


Asunto(s)
Mordeduras Humanas/clasificación , Odontología Forense/métodos , Registro de la Relación Maxilomandibular , Puntos Anatómicos de Referencia/patología , Brazo , Fenómenos Biomecánicos , Mordeduras Humanas/patología , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Rayos Láser , Modelos Anatómicos , Modelos Dentales , Odontometría/estadística & datos numéricos , Análisis de Componente Principal , Siliconas , Propiedades de Superficie , Diente/patología , Ceras/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA