Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Surg Endosc ; 24(9): 2293-8, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20177915

RESUMEN

BACKGROUND: The lack of triangulation of standard endoscopic devices limits the degree of freedom for surgical maneuvers during natural orifice transluminal endoscopic surgery (NOTES). This study explored the feasibility of adapting an intuitively controlled master and slave transluminal endoscopic robot (MASTER) the authors developed to facilitate wedge hepatic resection in NOTES. METHODS: The MASTER consists of a master controller, a telesurgical workstation, and a slave manipulator that holds two end-effectors: a grasper, and a monopolar electrocautery hook. The master controller is attached to the wrist and fingers of the operator and connected to the manipulator by electrical and wire cables. Movements of the operator are detected and converted into control signals driving the slave manipulator via a tendon-sheath power transmission mechanism allowing nine degrees of freedom. Using this system, wedge hepatic resection was performed through the transgastric route on two female pigs under general anesthesia. Entry into the peritoneal cavity was via a 10-mm incision made on the anterior wall of the stomach by the electrocautery hook. Wedge hepatic resection was performed using the robotic grasper and hook. Hemostasis was achieved with the electrocautery hook. After the procedure, the resected liver tissue was retrieved through the mouth using the grasper. RESULTS: Using the MASTER, transgastric wedge hepatic resection was successfully performed on two pigs with no laparoscopic assistance. The entire procedure took 9.4 min (range, 8.5-10.2 min), with 7.1 min (range, 6-8.2 min) spent on excision of the liver tissue. The robotics-controlled device was able to grasp, retract, and excise the liver specimen successfully in the desired plane. CONCLUSION: This study demonstrated for the first time that the MASTER could effectively mitigate the technical constraints normally encountered in NOTES procedures. With it, the triangulation of surgical tools and the manipulation of tissue became easy, and wedge hepatic resection could be accomplished successfully without the need for assistance using laparoscopic instruments.


Asunto(s)
Hepatectomía/métodos , Cirugía Endoscópica por Orificios Naturales/instrumentación , Cirugía Endoscópica por Orificios Naturales/métodos , Robótica , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Estudios de Factibilidad , Femenino , Proyectos Piloto , Estómago/cirugía , Porcinos , Grabación en Video
2.
Artículo en Inglés | MEDLINE | ID: mdl-19963992

RESUMEN

Although the flexible endoscopy has been widely used in the medical field for many years, there is still great potential in improving the endoscopist's capability to perform therapeutic tasks. Tentatively, tools for the flexible endoscope have poor maneuverability and limited Degree Of Freedom (DOF). In this paper, we propose a surgical robotic system MASTER (Master And Slave Transluminal Endoscopic Robot). MASTER is a dexterous and flexible master-slave device which can be used in tandem with a conventional flexible endoscope. Using this robotic system, ESD (Endoscopic Submucosal Dissection) and NOTES (Natural Orifice Transluminal Endoscopic Surgery) have been conducted on in vivo and ex vivo animal trials with promising results.


Asunto(s)
Endoscopios , Endoscopía/métodos , Robótica/instrumentación , Robótica/métodos , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Animales , Ingeniería Biomédica , Diseño de Equipo , Humanos , Hígado/cirugía , Modelos Animales
3.
Artículo en Inglés | MEDLINE | ID: mdl-19964181

RESUMEN

The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.


Asunto(s)
Endoscopios en Cápsulas , Tracto Gastrointestinal/fisiología , Humanos , Instrumentos Quirúrgicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA