Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Chromatogr A ; 1731: 465127, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39053256

RESUMEN

Reversed-phase (RP) liquid chromatography is an important tool for the characterization of materials and products in the pharmaceutical industry. Method development is still challenging in this application space, particularly when dealing with closely-related compounds. Models of chromatographic selectivity are useful for predicting which columns out of the hundreds that are available are likely to have very similar, or different, selectivity for the application at hand. The hydrophobic subtraction model (HSM1) has been widely employed for this purpose; the column database for this model currently stands at 750 columns. In previous work we explored a refinement of the original HSM1 (HSM2) and found that increasing the size of the dataset used to train the model dramatically reduced the number of gross errors in predictions of selectivity made using the model. In this paper we describe further work in this direction (HSM3), this time based on a much larger solute set (1014 solute/stationary phase combinations) containing selectivities for compounds covering a broader range of physicochemical properties compared to HSM1. The molecular weight range was doubled, and the range of the logarithm of the octanol/water partition coefficients was increased slightly. The number of active pharmaceutical ingredients and related synthetic intermediates and impurities was increased from four to 28, and ten pairs of closely related structures (e.g., geometric and cis-/trans- isomers) were included. The HSM3 model is based on retention measurements for 75 compounds using 13 RP stationary phases and a mobile phase of 40/60 acetonitrile/25 mM ammonium formate buffer at pH 3.2. This data-driven model produced predictions of ln α (chromatographic selectivity using ethylbenzene as the reference compound) with average absolute errors of approximately 0.033, which corresponds to errors in α of about 3 %. In some cases, the prediction of the trans-/cis- selectivities for positional and geometric isomers was relatively accurate, and the driving forces for the observed selectivity could be inferred by examination of the relative magnitudes of the terms in the HSM3 model. For some geometric isomer pairs the interactions mainly responsible for the observed selectivities could not be rationalized due to large uncertainties for particular terms in the model. This suggests that more work is needed in the future to explore other HSM-type models and continue expanding the training dataset in order to continue improving the predictive accuracy of these models. Additionally, we release with this paper a much larger data set (43,329 total retention measurements) at multiple mobile phase compositions, to enable other researchers to pursue their own lines of inquiry related to RP selectivity.


Asunto(s)
Cromatografía de Fase Inversa , Interacciones Hidrofóbicas e Hidrofílicas , Cromatografía de Fase Inversa/métodos , Isomerismo , Preparaciones Farmacéuticas/química , Preparaciones Farmacéuticas/análisis , Modelos Químicos , Peso Molecular , Agua/química
2.
J Chromatogr A ; 1705: 464182, 2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37442072

RESUMEN

Many contemporary challenges in liquid chromatography-such as the need for "smarter" method development tools, and deeper understanding of chromatographic phenomena-could be addressed more efficiently and effectively with larger volumes of experimental retention data than are available. The paucity of publicly accessible, high-quality measurements needed for the development of retention models and simulation tools has largely been due to the high cost in time and resources associated with traditional retention measurement approaches. Recently we described an approach to improve the throughput of such measurements by using very short columns (typically 5 mm), while maintaining measurement accuracy. In this paper we present a perspective on the characteristics of a dataset containing about 13,000 retention measurements obtained using this approach, and describe a different sample introduction method that is better suited to this application than the approach we used in prior work. The dataset comprises results for 35 different small molecules, nine different stationary phases, and several mobile phase compositions for each analyte/phase combination. During the acquisition of these data, we have interspersed repeated measurements of a small number of compounds for quality control purposes. The data from these measurements not only enable detection of outliers but also assessment of the repeatability and reproducibility of retention measurements over time. For retention factors greater than 1, the mean relative standard deviation (RSD) of replicate (typically n=5) measurements is 0.4%, and the standard deviation of RSDs is 0.4%. Most differences between selectivity values measured six months apart for 15 non-ionogenic compounds were in the range of +/- 1%, indicating good reproducibility. A critically important observation from these analyses is that selectivity defined as retention of a given analyte relative to the retention of a reference compound (kx/kref) is a much more consistent measure of retention over a time span of months compared to the retention factor alone. While this work and dataset also highlight the importance of stationary phase stability over time for achieving reliable retention measurements, we are nevertheless optimistic that this approach will enable the compilation of large databases (>> 10,000 measurements) of retention values over long time periods (years), which can in turn be leveraged to address some of the most important contemporary challenges in liquid chromatography. All the data discussed in the manuscript are provided as Supplemental Information.


Asunto(s)
Reproducibilidad de los Resultados , Cromatografía Liquida/métodos , Indicadores y Reactivos , Simulación por Computador , Bases de Datos Factuales , Cromatografía Líquida de Alta Presión/métodos
3.
J Chromatogr A ; 1678: 463350, 2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-35896047

RESUMEN

Efforts to model and simulate various aspects of liquid chromatography (LC) separations (e.g., retention, selectivity, peak capacity, injection breakthrough) depend on experimental retention measurements to use as the basis for the models and simulations. Often these modeling and simulation efforts are limited by datasets that are too small because of the cost (time and money) associated with making the measurements. Other groups have demonstrated improvements in throughput of LC separations by focusing on "overhead" associated with the instrument itself - for example, between-analysis software processing time, and autosampler motions. In this paper we explore the possibility of using columns with small volumes (i.e., 5 mm x 2.1 mm i.d.) compared to conventional columns (e.g., 100 mm x 2.1 mm i.d.) that are typically used for retention measurements. We find that isocratic retention factors calculated for columns with these dimensions are different by about 20%; we attribute this difference - which we interpret as an error in measurements based on data from the 5 mm column - to extra-column volume associated with inlet and outlet frits. Since retention factor is a thermodynamic property of the mobile/stationary phase system under study, it should be independent of the dimensions of the column that is used for the measurement. We propose using ratios of retention factors (i.e., selectivities) to translate retention measurements between columns of different dimensions, so that measurements made using small columns can be used to make predictions for separations that involve conventional columns. We find that this approach reduces the difference in retention factors (5 mm compared to 100 mm columns) from an average of 18% to an average absolute difference of 1.7% (all errors less than 8%). This approach will significantly increase the rate at which high quality retention data can be collected to thousands of measurements per instrument per day, which in turn will likely have a profound impact on the quality of models and simulations that can be developed for many aspects of LC separations.


Asunto(s)
Programas Informáticos , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Simulación por Computador , Indicadores y Reactivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA