Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 263: 116571, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39047650

RESUMEN

Periprosthetic infection is one of the most devastating complications following orthopaedic surgery. Rapid detection of an infection can change the treatment pathway and improve outcomes for the patient. In here, we propose a miniaturized lactate biosensor developed on a flexible substrate and integrated on a small-form bone implant to detect infection. The methods for lactate biosensor fabrication and integration on a bone implant are fully described within this study. The system performance was comprehensively electrochemically characterised, including with L-lactate solutions prepared in phosphate-buffered saline and culture medium, and interferents such as acetaminophen and ascorbic acid. A proof-of-concept demonstration was then conducted with ex vivo ovine femoral heads incubated with and without exposure to Staphylococcus epidermidis. The sensitivity, current density and limit-of-detection levels achieved by the biosensor were 1.25 µA mM-1, 1.51 µA.M-1.mm-2 and 66 µM, respectively. The system was insensitive to acetaminophen, while sensitivity to ascorbic acid was half that of the sensitivity to L-lactate. In the ex vivo bone model, S. epidermidis infection was detected within 5 h of implantation, while the control sample led to no change in the sensor readings. This pioneering work demonstrates a pathway to improving orthopaedic outcomes by enabling early infection diagnosis.


Asunto(s)
Técnicas Biosensibles , Ácido Láctico , Infecciones Estafilocócicas , Staphylococcus epidermidis , Infección de la Herida Quirúrgica , Técnicas Biosensibles/métodos , Animales , Staphylococcus epidermidis/aislamiento & purificación , Ovinos , Infecciones Estafilocócicas/diagnóstico , Infección de la Herida Quirúrgica/diagnóstico , Ácido Láctico/análisis , Ácido Láctico/química , Humanos , Tecnología Inalámbrica , Prótesis e Implantes , Diseño de Equipo , Infecciones Relacionadas con Prótesis , Enzimas Inmovilizadas/química , Ortopedia , Oxigenasas de Función Mixta
2.
Front Bioeng Biotechnol ; 11: 1305936, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38107615

RESUMEN

Modern orthopaedic implants use lattice structures that act as 3D scaffolds to enhance bone growth into and around implants. Stochastic scaffolds are of particular interest as they mimic the architecture of trabecular bone and can combine isotropic properties and adjustable structure. The existing research mainly concentrates on controlling the mechanical and biological performance of periodic lattices by adjusting pore size and shape. Still, less is known on how we can control the performance of stochastic lattices through their design parameters: nodal connectivity, strut density and strut thickness. To elucidate this, four lattice structures were evaluated with varied strut densities and connectivity, hence different local geometry and mechanical properties: low apparent modulus, high apparent modulus, and two with near-identical modulus. Pre-osteoblast murine cells were seeded on scaffolds and cultured in vitro for 28 days. Cell adhesion, proliferation and differentiation were evaluated. Additionally, the expression levels of key osteogenic biomarkers were used to assess the effect of each design parameter on the quality of newly formed tissue. The main finding was that increasing connectivity increased the rate of osteoblast maturation, tissue formation and mineralisation. In detail, doubling the connectivity, over fixed strut density, increased collagen type-I by 140%, increased osteopontin by 130% and osteocalcin by 110%. This was attributed to the increased number of acute angles formed by the numerous connected struts, which facilitated the organization of cells and accelerated the cell cycle. Overall, increasing connectivity and adjusting strut density is a novel technique to design stochastic structures which combine a broad range of biomimetic properties and rapid ossification.

3.
Biomater Adv ; 154: 213590, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37598437

RESUMEN

Smart implantable electronic medical devices are being developed to deliver healthcare that is more connected, personalised, and precise. Many of these implantables rely on piezoceramics for sensing, communication, energy autonomy, and biological stimulation, but the piezoceramics with the strongest piezoelectric coefficients are almost exclusively lead-based. In this article, we evaluate the electromechanical and biological characteristics of a lead-free alternative, 0.94Bi0.5Na0.5TiO3-0.06BaTiO3 (BNT-6BT), manufactured via two synthesis routes: the conventional solid-state method (PIC700) and tape casting (TC-BNT-6BT). The BNT-6BT materials exhibited soft piezoelectric properties, with d33 piezoelectric coefficients that were inferior to commonly used PZT (PIC700: 116 pC/N; TC-BNT-6BT: 121 pC/N; PZT-5A: 400 pC/N). The material may be viable as a lead-free substitute for soft PZT where moderate performance losses up to 10 dB are tolerable, such as pressure sensing and pulse-echo measurement. No short-term harmful biological effects of BNT-6BT were detected and the material was conducive to the proliferation of MC3T3-E1 murine preosteoblasts. BNT-6BT could therefore be a viable material for electroactive implants and implantable electronics without the need for hermetic sealing.


Asunto(s)
Comercio , Prótesis e Implantes , Animales , Ratones , Iones , Comunicación , Electrónica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA