Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
4.
Am Heart J ; 146(4): E13, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14564336

RESUMEN

BACKGROUND: Debate exists regarding selection of the prosthesis type most likely to maximize early left ventricular (LV) mass regression after aortic valve replacement (AVR) for stenotic valvular disease. The aim of this study was to compare the degree of LV mass regression measured by MRI 6 months after prospectively randomized valve implantation for two biological prostheses, stented and stentless, and for two mechanical valves, tilting disc and bileaflet. METHODS: Thirty-nine consecutive patients with predominant aortic stenosis accepted for elective AVR were studied. Twenty patients requiring a tissue prosthesis were randomly assigned to receive either a Freestyle or Mosaic valve. The remaining 19 patients in whom mechanical prosthesis was indicated were randomly assigned to receive either an Ultracor or an ATS valve. RESULTS: There was no difference in valve size implanted between the compared groups. LV mass measurements were performed with MRI (1.5-T Vision, Siemens, Germany) immediately before and 6 months after surgery. All valve types produced significant postoperative reduction in LV mass compared with preoperative values (P <.01). Percent change in LV mass regression was similar between the two porcine valve types, Mosaic (24.4% +/- 11.1%) and Freestyle (21.1% +/- 16.7%), and between the two mechanical valve designs, Ultracor (19.3% +/- 9.5%) and ATS (26.3% +/- 10.8%), respectively. CONCLUSIONS: Significant LV remodeling occurs early after AVR for aortic stenosis. The degree of regression in LV mass is independent of prosthesis type implanted.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Hipertrofia Ventricular Izquierda/cirugía , Remodelación Ventricular , Adulto , Anciano , Bioprótesis , Femenino , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/fisiopatología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Inducción de Remisión
5.
Clin Radiol ; 57(6): 498-501, 2002 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12069467

RESUMEN

The magnetic resonance imaging (MRI) assessment of myocardial function and perfusion is a valuable complementary technique to coronary angiography. We describe a method of presenting and collating regional MRI data with the angiographic findings as annotated by the Green Lane reporting system. Routine clinical use of this approach is likely to increase the accuracy of MRI data interpretation and to influence both medical and interventional treatment strategies.


Asunto(s)
Enfermedad Coronaria/diagnóstico , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA