Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Am Chem Soc ; 146(34): 23963-23971, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39158696

RESUMEN

Photoacoustic imaging is an emerging modality with significant promise for biomedical applications such as neuroimaging, owing to its capability to capture large fields of view deep inside complex scattering tissue. However, widespread adoption of this technique has been hindered by a lack of suitable molecular reporters for this modality. In this work, we introduce chemigenetic labels and calcium sensors specifically tailored for photoacoustic imaging, using a combination of synthetic dyes and HaloTag-based self-labeling proteins. We rationally design and engineer far-red "acoustogenic" dyes, showing high photoacoustic turn-ons upon binding to HaloTag, and develop a suite of tunable calcium indicators based on these scaffolds. These first-generation photoacoustic reporters show excellent performance in tissue-mimicking phantoms, with the best variants outperforming existing sensors in terms of signal intensity, sensitivity, and photostability. We demonstrate the application of these ligands for labeling HaloTag-expressing neurons in mouse brain tissue, producing strong, specifically targeted photoacoustic signal, and provide a first example of in vivo labeling with these chemigenetic photoacoustic probes. Together, this work establishes a new approach for the design of photoacoustic reporters, paving the way toward deep tissue functional imaging.


Asunto(s)
Calcio , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Calcio/química , Animales , Ratones , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Humanos
2.
Opt Express ; 28(19): 27940-27950, 2020 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-32988076

RESUMEN

Limited operating bandwidth originated from strong absorption of glass materials in the infrared (IR) spectral region has hindered the potential applications of microstructured optical waveguide (MOW)-based sensors. Here, we demonstrate multimode waveguide regime up to 6.5 µm for the hollow-core (HC) MOWs drawn from borosilicate soft glass. Effective light guidance in central HC (diameter ∼240 µm) was observed from 0.4 to 6.5 µm despite high waveguide losses (0.4 and 1 dB/cm in near- and mid-IR, respectively). Additional optimization of the waveguide structure can potentially extend its operating range and decrease transmission losses, offering an attractive alternative to tellurite and chalcogenide-based fibers. Featuring the transparency in mid-IR, HC MOWs are promising candidates for the creation of MOW-based sensors for chemical and biomedical applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA