Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Nucl Cardiol ; 5(5): 477-83, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9796894

RESUMEN

BACKGROUND: This study sought to assess the repeatability of automatic quantitative measurements of left ventricular (LV) cavity volumes in a large patient population (N = 926), to correlate those measurements to similarly obtained LV ejection fraction (LVEF) measurements, and to investigate the relationship between ungated and gated volumes. METHODS: All 926 patients underwent ungated single photon emission computed tomography (SPECT) immediately followed by 8-frame gated SPECT. LV cavity volumes were automatically measured from ungated (V), summed gated (SUMV), end-systolic (ESV) and end-diastolic (EDV) images, and LVEFs derived from the latter 2. RESULTS: Repeatability (SUMV vs V) was very good overall (6.4%+/-6.6%), further improving for volumes >25 mL (5.7%+/-5.5%) and >40 mL (5.2%+/-5.0%). Exponential regression between ESV and LVEF (r = 0.925, SEE = 15.0 mL), EDV and LVEF (r = 0.802, SEE = 24.2 mL), and SUMV and LVEF (r = 0.867, SEE = 19.7 mL) was also very good. Summed gated volumes were closer to ESV than to EDV (43.3%+/-8.8% of EDV-ESV range). SUMV <50 mL and SUMV >110 mL were good substitutes for LVEF >50% and LVEF <40% (93.4% and 97.1%, respectively). CONCLUSION: Automatic quantitative measurements of gated and ungated volumes with our algorithm are repeatable, correlate well with other global myocardial parameters, and may contribute important additional information to that conventionally provided by myocardial perfusion SPECT studies.


Asunto(s)
Corazón/diagnóstico por imagen , Volumen Sistólico , Tomografía Computarizada de Emisión de Fotón Único , Función Ventricular Izquierda , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
2.
Clin Nucl Med ; 15(7): 495-500, 1990 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-2383940

RESUMEN

An automated volume determination program using SPECT imaging with Tc-99m has been validated by both phantom and patient studies. Its use for monitoring change of function of the liver and change in tumor mass during different therapy regimes has been assessed. The technique is not restricted to the estimation of the hepatic functioning tissues; it therefore has many potential clinical implementations for volume determination in other organs.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Hígado/diagnóstico por imagen , Programas Informáticos , Azufre Coloidal Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Humanos , Hígado/patología , Hígado/fisiopatología , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/fisiopatología , Modelos Estructurales , Monitoreo Fisiológico/métodos , Bazo/anatomía & histología , Bazo/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA