Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Case Rep Oncol ; 9(2): 379-86, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27489542

RESUMEN

INTRODUCTION: The prognostic outcome following progression after palliative first-line treatment for patients suffering from metastatic colorectal adenocarcinoma is generally poor. Long-term relapse-free survival with palliative second-line treatment may be achieved in only a limited number of individual cases. CASE REPORT: A 37-year-old patient presented with bilobar liver metastases of colon cancer confirmed by histology with wild-type K-RAS (exon 2). Due to progressive disease after eight cycles of first-line therapy with FOLFIRI plus cetuximab, second-line chemotherapy with modified FOLFOX4 (mFOLFOX4) plus bevacizumab was initiated. During four cycles of mFOLFOX4 plus bevacizumab (2 months), no higher-grade toxicity occurred. Liver MRI with contrast medium revealed downsizing of the segment II/III metastases, as well as regressive, small, faint, hardly definable lesions in segments VI and IVb. The interdisciplinary tumor board of the University of Erlangen thus decided to perform resection of the liver metastases. Segments II and III were resected, and the liver metastases in segments IVa and VI were excised (R0). Histopathology confirmed three of the R0-resected metastases to be completely necrotic, with residual scarring. As perioperative therapy, four additional cycles of mFOLFOX4 plus bevacizumab were administered postoperatively. No higher-grade toxicity was observed. Three years after the initial diagnosis, the patient is relapse free, professionally fully reintegrated, and has an excellent performance status. CONCLUSION: Patients suffering from metastatic colorectal cancer may benefit from multidisciplinary treatment with secondary metastatic liver resection after downsizing by palliative second-line treatment. In individual cases, patients may even have a curative treatment option, provided that close interdisciplinary collaboration exists.

2.
Head Face Med ; 12: 15, 2016 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-27037010

RESUMEN

BACKGROUND: The purpose of this study was to assess the influence of head and neck pathologies on the detection rate, configuration and diameter of the thoracic duct (TD) and right lymphatic duct (RLD) in computed tomography (CT) of the head and neck. METHODS: One hundred ninety-seven patients were divided into the subgroups "healthy", "benign disease" and "malignant disease". The interpretation of the images was performed at a slice thickness of 3 mm in the axial and coronal plane. In each case we looked for the distal part of the TD and RLD respectively and subsequently evaluated their configuration (tubular, sacciform, dendritic) as well as their maximum diameter and correlated the results with age, gender and diagnosis group. RESULTS: The detection rate in the study population was 81.2 % for the TD and 64.2 % for the RLD and did not differ significantly in any of the subgroups. The predominant configuration was tubular. The configuration distribution did not differ significantly between the diagnosis groups. The mean diameter of the TD was 4.79 ± 2.41 mm and that of the RLD was 3.98 ± 1.96 mm. No significant influence of a diagnosis on the diameter could be determined. CONCLUSIONS: There is no significant influence of head/neck pathologies on the CT detection rate, morphology or size of the TD and RLD. However our study emphasizes that both the RLD and the TD are detectable in the majority of routine head and neck CTs and therefore reading physicians and radiologists should be familiar with their various imaging appearances.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Ganglios Linfáticos/diagnóstico por imagen , Conducto Torácico/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Medios de Contraste , Femenino , Neoplasias de Cabeza y Cuello/patología , Humanos , Ganglios Linfáticos/patología , Masculino , Persona de Mediana Edad , Conducto Torácico/patología
3.
J Digit Imaging ; 29(2): 183-8, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26438423

RESUMEN

To investigate whether abdominopelvic hemorrhage shown on computed tomography (CT) images can be diagnosed with the same accuracy on a tablet computer as on a dedicated reading display. One hundred patients with a clinical suspicion of abdominopelvic hemorrhage that underwent biphasic CT imaging were retrospectively read by two readers on a dedicated reading display (reference standard) and on a tablet computer (iPad Air). Reading was performed in a dedicated reading room with ambient light conditions. Image evaluation included signs of an active hemorrhage (extravasation of contrast media) and different signs indicating a condition after abdominopelvic hemorrhage (hematoma, intestinal clots, vessel stump, free abdominopelvic fluid with a mean Hounsfield unit value >20, and asymmetric muscle volume indicating intramuscular hemorrhage). Sensitivity, specificity, and positive and negative predictive values (PPV/NPV) were calculated for the tablet-based reading. Active abdominopelvic hemorrhage (n = 72) was diagnosed with the tablet computer with a sensitivity of 0.96, a specificity of 0.93, a PPV of 0.97, and an NPV of 0.90. The results for the detection of the signs indicating a condition after abdominopelvic hemorrhage range from 0.83 to 1.00 in the case of sensitivity, from 0.95 to 1.00 in the case of specificity, from 0.94 to 1.00 in the case of the PPV, and from 0.96 to 1.00 in the case of the NPV. Abdominopelvic hemorrhage shown on CT images can be diagnosed on a tablet computer with a high diagnostic accuracy allowing mobile on-call diagnoses. This may be helpful because an early and reliable diagnosis at any time is crucial for an adequate treatment strategy.


Asunto(s)
Computadoras de Mano/normas , Hemorragia/diagnóstico por imagen , Pelvis/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Tomografía Computarizada por Rayos X , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Estudios Retrospectivos
4.
J Telemed Telecare ; 21(6): 355-63, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25962651

RESUMEN

The growing complexity of radiologic examinations and interventional procedures requires frequent exchange of knowledge. Consequently a simple way to share and discuss patient images between radiology experts and with colleagues from other medical disciplines is needed. Aims of this work were the development and initial performance evaluation of a fast and user friendly, platform independent teleconsultation system for medical imaging. A local back end system receives DICOM images and generates anonymized JPEG files that are uploaded to an internet webserver. The front end running on that webserver comprises an image viewer with a specially developed pointer element for indicating findings to collaborative partners. The front end that uses only standard web technologies works on a variety of different platforms, mobile devices and desktop computers. Images can be accessed by simply calling up a special internet address in a web browser that may be exchanged between users (e.g. via email). A speed evaluation of the system showed good results: For example the preparation and upload of a standard head CT took less than 21 seconds. The data volume of the same series and the viewer application could be transferred to a mobile phone in less than 42 seconds via a UMTS network or in less than 3 seconds via a HSPA network. The presented system with its minimal hard- and software requirements, its simplicity and platform independence might be a promising tool in the increasingly important area of teleconsultation.


Asunto(s)
Internet , Sistemas de Información Radiológica , Consulta Remota/métodos , Telerradiología , Humanos , Consulta Remota/instrumentación , Programas Informáticos , Telerradiología/instrumentación
5.
Pediatr Radiol ; 45(5): 651-7, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25407955

RESUMEN

BACKGROUND: Cardiac MRI is an accurate and reproducible technique for the assessment of left ventricular volumes and function. The accuracy of automated segmentation and the effects of manual adjustments have not been determined in children. OBJECTIVE: To evaluate automated segmentation and the effects of manual adjustments for left ventricular parameter quantification in pediatric cardiac MR images. MATERIALS AND METHODS: Left ventricular parameters were evaluated in 45 children with suspected myocarditis (age 13.4 ± 3.5 years, range 4-17 years) who underwent cardiac MRI. Dedicated software was used to automatically segment and adjust the parameters. Results of end-diastolic volume, end-systolic volume, stroke volume, myocardial mass, and ejection fraction were documented before and after apex/base adjustment and after apex/base/myocardial contour adjustment. RESULTS: The software successfully detected the left ventricle in 42 of 45 (93.3%) children; failures occurred in the smallest and youngest children. Of those 42 children, automatically segmented end-diastolic volume (EDV) was 151 ± 47 ml, and after apex/base adjustment it was 146 ± 45 ml, after apex/base/myocardial contour adjustment 146 ± 45 ml. The corresponding results for end-systolic volume (ESV) were 66 ± 32 ml, 63 ± 29 ml and 64 ± 28 ml; for stroke volume (SV) they were 85 ± 25 ml, 83 ± 23 ml and 83 ± 23 ml; for ejection fracture (EF) they were 57 ± 10%, 58 ± 9% and 58 ± 9%, and for myocardial mass (MM) they were 104 ± 31 g, 95 ± 31 g and 94 ± 30 g. Statistically significant differences were found when comparing the EDV/ESV/MM results, the EF results after apex/base adjustment and after apex/base/myocardial contour adjustment and the SV results (except for comparing the SVs after apex/base adjustment and after apex/base/myocardial contour adjustment). CONCLUSION: Automated segmentation for the evaluation of left ventricular parameters in pediatric MR images proved to be feasible. Automated segmentation + apex/base adjustment provided clinically acceptable parameters for the majority of cases.


Asunto(s)
Imagen por Resonancia Magnética , Miocarditis/patología , Disfunción Ventricular Izquierda/patología , Adolescente , Niño , Preescolar , Femenino , Ventrículos Cardíacos/patología , Humanos , Masculino , Miocarditis/complicaciones , Tamaño de los Órganos , Reproducibilidad de los Resultados , Volumen Sistólico , Disfunción Ventricular Izquierda/complicaciones
6.
PLoS One ; 9(9): e106445, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25180580

RESUMEN

BACKGROUND: To prove effectiveness of wrapping tablet computers in order to reduce microbiological contamination and to evaluate whether a plastic bag-covered tablet leads to impaired user satisfaction or touchscreen functionality. MATERIALS AND METHODS: Within a period of 11 days 115 patients were provided with a tablet computer while waiting for their magnetic resonance imaging examination. Every day the contamination of the surface of the tablet was determined before the first and after the final use. Before the device was handed over to a patient, it was enclosed in a customized single-use plastic bag, which was analyzed for bacterial contamination after each use. A questionnaire was applied to determine whether the plastic bag impairs the user satisfaction and the functionality of the touchscreen. RESULTS: Following the use by patients the outside of the plastic bags was found to be contaminated with various bacteria (657.5 ± 368.5 colony forming units/day); some of them were potentially pathogenic. In contrast, the plastic bag covered surface of the tablet was significantly less contaminated (1.7 ± 1.9 colony forming units/day). Likewise, unused plastic bags did not show any contamination. 11% of the patients reported problems with the functionality of the touchscreen. These patients admitted that they had never used a tablet or a smartphone before. CONCLUSIONS: Tablets get severely contaminated during usage in a clinical setting. Wrapping with a customized single-use plastic bag significantly reduces microbiological contamination of the device, protects patients from the acquisition of potentially pathogenic bacteria and hardly impairs the user satisfaction and the functionality of the touchscreen.


Asunto(s)
Computadores , Contaminación de Equipos , Higiene de las Manos , Bacterias/crecimiento & desarrollo , Recuento de Colonia Microbiana , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción Personal , Plásticos
7.
Med Sci Monit ; 17(8): CS103-107, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21804467

RESUMEN

BACKGROUND: Metastatic insulinoma is a disease associated with a poor life expectancy. CASE REPORT: The case of a presently 68 year old female with malignant, metastatic insulinoma is reported. Due to severe clinical symptoms surgical tumor mass reduction was conducted. Furthermore the patient underwent a chemotherapy using streptozotocine and fluorouracil. After two years without any symptoms, the remaining hepatic metastases increased in size and again hypoglycemias occurred. To reachieve an asymptomatic state and further reduction in tumor mass, the decision was made for transarterial chemoembolization with streptozotocine. After the first treatment the patient was hypoglycemia - free for 3 months, after another more extensive chemoembolization the patient is presently symptom free for 8 months. CONCLUSIONS: Since the diagnosis of extended disease was established, the patient has survived for 36 months. We regard this as the result of a multimodal approach and the extensive use of local tumor therapy. The different therapeutic options for local tumor therapy are reported and discussed.


Asunto(s)
Insulinoma/patología , Insulinoma/terapia , Neoplasias Hepáticas/secundario , Tasa de Supervivencia , Anciano , Quimioembolización Terapéutica , Femenino , Humanos , Hipoglucemia/etiología , Hipoglucemia/terapia , Insulinoma/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA