Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Gait Posture ; 99: 90-97, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36368241

RESUMEN

BACKGROUND: Sprint performance can be characterized through the centre of mass (COM) velocity over time. In-field computation of the COM is key in sprint training. RESEARCH QUESTION: To compare the stance-averaged COM velocity computation from a Magneto-Inertial Measurement Units (MIMU) to a reference system: force platforms (FP), over the early acceleration phase in both straight and curve sprinting. METHODS: Nineteen experienced-to-elite track sprinters performed 1 maximal sprint on both the straight and the curve (radius = 41.58 m) in a randomized order. Utilizing a MIMU-based system (Xsens MVN Link) and compared to FP (Kistler), COM velocity was computed with both systems. Averaged stance-by-stance COM velocity over straight-line and curve sprinting following the vertical axis (respectively VzMIMU and VzFP) and the norm of the two axes lying on the horizontal plane: x and y, approximately anteroposterior and mediolateral (respectively VxyMIMU and VxyFP) over the starting-blocks (SB) and initial acceleration (IA - composed out of the first four stances following the SB) were compared using mean bias, 95 % limits of agreements and Pearson's correlation coefficients. RESULTS: 148 stances were analyzed. VxyMIMU mean bias was comprised between 0.26 % and 2.03 % (expressed in % with respect to the FP) for SB, 5.63 % and 7.29 % over IA respectively on the straight and the curve. Pearson's correlation coefficients ranged between 0.943 and 0.990 for Vxy, 0.423 and 0.938 for Vz. On the other hand, VzMIMU mean bias ranged between 2.33 % and 4.69 % for SB, between 1.44 % and 19.95 % over IA respectively on the straight and the curve SIGNIFICANCE: The present findings suggest that the MIMU-based system tested slightly underestimated VxyMIMU, though within narrow limits which supports its utilization. On the other hand, VzMIMU computation in sprint running is not fully mature yet. Therefore, this MIMU-based system represents an interesting device for in-fieldVxyMIMU computation either for straight-line and curve sprinting.


Asunto(s)
Rendimiento Atlético , Carrera , Humanos , Fenómenos Biomecánicos , Aceleración , Fenómenos Magnéticos
2.
Sensors (Basel) ; 22(22)2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36433206

RESUMEN

To directly compare five commonly used on-field systems (motorized linear encoder, laser, radar, global positioning system, and timing gates) during sprint acceleration to (i) measure velocity−time data, (ii) compute the main associated force−velocity variables, and (iii) assess their respective inter-trial reliability. Eighteen participants performed three 40 m sprints, during which five systems were used to simultaneously and separately record the body center of the mass horizontal position or velocity over time. Horizontal force−velocity mechanical outputs for the two best trials were computed following an inverse dynamic model and based on an exponential fitting of the position- or velocity-time data. Between the five systems, the maximal running velocity was close (7.99 to 8.04 m.s−1), while the time constant showed larger differences (1.18 to 1.29 s). Concurrent validity results overall showed a relative systematic error of 0.86 to 2.28% for maximum and theoretically maximal velocity variables and 4.78 to 12.9% for early acceleration variables. The inter-trial reliability showed low coefficients of variation (all <5.74%), and was very close between all of the systems. All of the systems tested here can be considered relevant to measure the maximal velocity and compute the force−velocity mechanical outputs. Practitioners are advised to interpret the data obtained with either of these systems in light of these results.


Asunto(s)
Rendimiento Atlético , Carrera , Humanos , Aceleración , Fenómenos Biomecánicos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA