Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Intervalo de año de publicación
1.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-941947

RESUMEN

OBJECTIVE@#To explore the effects from the thread shapes of custom-made root-analogue implant (RAI) on distributions of von Mises stress around the peri-implant bone.@*METHODS@#Five one-stage RAI three-dimensional finite element (FE) models with different thread shapes (V-shaped design, square design, buttress design, reverse buttress design and none thread design) and congruent bone were created through reverse engineering technology. The data of the five models were imported into the FE analysis software to calculate. A force of 100 N was applied parallelly and of 45° to the implant axis respectively. Analysis was performed to evaluate the von Mises stress distributions at the peri-implant regions with the help of the Ansys 16 software.@*RESULTS@#The von Mises stresses distributed mostly at the implant cervical regions and the tip ends of the threads on the cortical bone under oblique loading, while on the cancellous bone, the stresses concentrated mostly on the implant lateral cervical regions, the tip ends of the threads and the apical regions. When under vertical loading, the von Mises stresses distributed mostly at the implant cervical regions on the cortical bone while at the tip ends of the threads and the lateral apical regions on the cancellous bone. The von Mises stresses were better distributed on the thread groups under both kinds of loadings compared with no thread design. But there was no obvious difference among the different thread groups. The concentrations of the von Mises stresses on the cancellous bone in the thread groups were mostly at the tip ends of the threads while less in the apical area. The von Mises stresses were better distributed on the cancellous bone on the other three thread designs than on square design.@*CONCLUSION@#Thread designs are advocated for the reason that adding thread designs to the RAI standard design will have a positive effect on stress distributions at the peri-implant regions and it will reduce the concentrations of von Mises stresses on the cortical bone. From the standpoint of the stress distribution, V-shaped design, buttress design and reverse buttress design are more suitable for RAI than square design. There is no difference of the distributions of the von Mises stresses in the RAI between different thread designs.


Asunto(s)
Fenómenos Biomecánicos , Simulación por Computador , Implantes Dentales , Diseño de Prótesis Dental , Análisis del Estrés Dental , Análisis de Elementos Finitos , Programas Informáticos , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA