Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Optom Vis Sci ; 100(11): 751-760, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37861987

RESUMEN

SIGNIFICANCE: Recently, novel refraction technology allows subjective refractions to be performed with a higher-resolution. It is unclear, however, if these benefits are noticed and appreciated by the patient during the examination and after dispensing. PURPOSE: This study investigated benefits and drawbacks of high-resolution refraction technology over standard, specifically in terms of the refraction, glasses prescription, and participant's perceptions of the technology. METHODS: Sixty progressive-addition-lens wearers (aged 35 to 70 years) and 60 single-vision wearers (18 years or older) were randomized to a high-resolution refraction (Vision-R 800; Essilor Instruments, Dallas, TX; essilorinstrumentsusa.com ) and standard refraction in a 2-week crossover dispensing design. Refractive results were converted to M, J0, and J45 and analyzed using multivariate t tests. Bayesian estimation was used to analyze differences between refraction type and age group for subjective outcomes. RESULTS: Differences in refractive error between the two refractions were small, and none differed statistically ( P > .05) or clinically (e.g., <0.25 D) in either subgroup. Visual acuities at distance and near were better than 0.00 logMAR; none of the mean differences between the refractions reached statistical or clinical (e.g., <0.10 D) significance. Participants significantly preferred the high-resolution refraction for its quickness and efficiency, improved comfort, and less stress. Bayesian analysis indicated a 76% probability that participants had higher confidence in the high-resolution refraction, 93% probability that they would seek it out for their care, and 94% probability that they would recommend an optometrist using this technology. CONCLUSIONS: Refractive and acuity endpoints were similar with the high-resolution and standard refraction. Participants, however, perceived several key benefits of the high-resolution refraction and prescription for their care, the care of their friends/family, and the practice itself.


Asunto(s)
Refracción Ocular , Errores de Refracción , Humanos , Teorema de Bayes , Prescripciones , Errores de Refracción/terapia , Errores de Refracción/diagnóstico , Reproducibilidad de los Resultados , Pruebas de Visión , Agudeza Visual , Adulto , Persona de Mediana Edad , Anciano , Adolescente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA