1.
JACC Cardiovasc Interv ; 17(17): 2023-2037, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39260960

RESUMEN

BACKGROUND: Research on the role of transcatheter heart valve (THV) deformation and calcium distribution in patients with bicuspid aortic valves (BAVs) undergoing transcatheter aortic valve replacement (TAVR) remains limited. OBJECTIVES: The aim of this study was to evaluate the impact of THV deformation on clinical outcomes in individuals with BAVs undergoing TAVR and the influence of calcium on these outcomes. METHODS: In total, 229 consecutive patients with BAVs who underwent TAVR with balloon-expandable valves and had computed tomography (CT) performed 30 days post-TAVR were analyzed. Patients were stratified into 3 groups: group 1 (n = 125), with no THV underexpansion or eccentricity; group 2 (n = 69), with underexpansion or eccentricity; and group 3 (n = 35), with both. Calcium distribution was assessed using CT, and its associations with clinical outcomes, including all-cause mortality at 3 years and leaflet thrombosis at 30 days, were determined. A subgroup analysis of patients with type 1 BAVs was conducted. RESULTS: Group 3 exhibited higher rates of all-cause mortality than the other groups, along with the highest risk for hypoattenuated leaflet thickening at 30 days. Multivariate analysis identified annular and left ventricular outflow tract calcification as independent predictors of all-cause mortality and hypoattenuated leaflet thickening. In patients with type 1 BAVs, excessive calcification at the raphe and opposite leaflet were associated with all-cause mortality at 3 years. CONCLUSIONS: THV deformation post-TAVR was significantly linked to all-cause mortality in patients with BAVs. Annular and left ventricular outflow tract calcification correlated with increased risks for all-cause mortality and leaflet thrombosis. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Calcinosis/mortalidad , Valvuloplastia con Balón/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Trombosis/diagnóstico por imagen , Trombosis/etiología , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas
2.
Radiology ; 312(2): e240229, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39136569

RESUMEN

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (r = 0.92; P < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; P = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm3 [95% LoA: -0.27 cm3, 0.19 cm3] and 0.02 cm3 [95% LoA: -0.14 cm3, 0.19 cm3], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almeida in this issue.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Angiografía por Tomografía Computarizada , Fibrosis , Humanos , Masculino , Estudios Prospectivos , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Persona de Mediana Edad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Fibrosis/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Anciano
3.
Struct Heart ; 8(4): 100293, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39100579

RESUMEN

Background: The Navitor Investigational Device Exemption (IDE) study is a prospective, multicenter, global study assessing the safety and effectiveness of the Navitor valve in a population with severe, symptomatic aortic stenosis who are at high and extreme surgical risk. The impact of pre-existing conduction abnormalities and implantation technique on new permanent pacemaker implantation (PPI) for the Navitor platform is not fully understood. Therefore, the goal of this analysis was to investigate the associations between patient and procedural factors and the 30-day new PPI rate. Methods: A total of 260 patients who underwent implantation of a Navitor valve in the Navitor IDE study were reviewed. Patients with preprocedural permanent pacemakers (n = 28) were excluded. Baseline risk factors were assessed for statistical significance. Multivariable logistic regression analyses were performed to identify independent predictors of new PPI. Results: Mean age of the pacemaker-naïve population was 83.3 ± 5.2 years, 58.6% were female, average Society of Thoracic Surgeons score was 3.8% ± 1.9%, median frailty score was 1 (interquartile range 1, 2), and 17.7% were deemed at extreme surgical risk. Pre-existing first-degree atrioventricular block and right bundle branch block significantly increased the risk of new PPI postimplantation, whereas left bundle branch block did not. Membranous septum length in relation to noncoronary cusp implant depth was a significant predictor of new PPI, with higher rates of new PPI observed when noncoronary cusp implant depth exceeded membranous septum length. Analysis of implant depth alone revealed deeper implants were associated with a higher rate of new PPI, regardless of patient baseline conduction abnormality. Conclusions: The 30-day rate of new PPI in the Navitor IDE study is associated with patient pre-existing baseline conduction disturbances and implantation depth.

4.
EClinicalMedicine ; 72: 102603, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39010979

RESUMEN

Background: The permanent pacemaker (PPM) implantation and pacemaker dependency rates after transcatheter aortic valve replacement (TAVR) are highly variable as some of the conduction disturbances are reversible. It remains poorly investigated how to optimise temporary pacing in these patients. This study aimed to explore the potential reduction in the PPM implantation rate using temporary-permanent pacemaker (TPPM) as a 1-month bridge. Methods: This is a prospective, multicentre, single-arm, observational study. Consecutive patients undergoing TAVR from March 1, 2022 to March 1, 2023 in 13 tertiary hospitals in China were screened. Patients who developed high-degree atrioventricular block, complete heart block, or first-degree atrioventricular block plus new onset left bundle branch block during the TAVR procedure or within 1 month after TAVR were included to receive TPPM. Patients with pre-existing PPM implantation or indications for PPM implantation before the TAVR procedure were excluded. Patients with TPPM were monitored to determine whether the conduction disturbances persisted or recovered. The primary endpoint was the rate of freedom from indications for PPM implantation 1 month after TAVR. This study is registered with ChiCTR, ChiCTR2200057931. Findings: Of 688 patients who have undergone TAVR, 71 developed conduction disturbance and met the inclusion criteria, 1 patient withdrew due to noncompliance, 70 patients received TPPM and completed follow-up. There were 41 (58.6%) men and 29 (41.4%) women in the study, with a mean age of 74.3 ± 7.3 years. At 1 month follow-up, 75.7% (53/70) of the patients with TPPM did not require PPM implantation. For 688 patients who have undergone TAVR, the rate of PPM implantation at 1 month was 2.47% (17/688, 95% CI 1.55%-3.92%), representing a significant reduction in self-comparison with the rate at 48 h after TPPM (2.47% vs. 8.28% [95% CI 6.45%-10.58%], P < 0.0001). Similar results were obtained in the subgroup analysis of patients with HAVB/CHB. Multivariate analysis revealed the baseline PR interval, difference between the membranous septum length and implantation depth, and timing of postprocedural conduction disturbance occurrence were independent predictors of freedom from indications for PPM implantation at 1 month after TAVR. Interpretation: Using TPPM as a 1-month bridge allows for a buffer period to distinguish whether conduction disturbances are reversible or persistent, resulting in a significant reduction in the PPM implantation rate after TAVR when compared with the current strategy. However, this is an observational study, the results need to be confirmed in a randomized trial. Funding: Beijing Science and Technology Plan 2022 from Beijing Municipal Science & Technology Commission.

6.
JACC Cardiovasc Interv ; 17(14): 1631-1651, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048251

RESUMEN

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Riesgo , Toma de Decisiones Clínicas , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Terminología como Asunto , Valor Predictivo de las Pruebas
7.
Am J Cardiol ; 224: 46-54, 2024 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-38844194

RESUMEN

Residual significant mitral regurgitation (MR) can increase the risk of adverse events after transcatheter aortic valve replacement (TAVR). The clinical benefits of staged transcatheter edge-to-edge repair (TEER) after TAVR remain underexplored. This study aimed to investigate the clinical outcomes of staged TEER for residual significant MR after TAVR. This observational study included 314 consecutive patients with chronic residual grade 3+ or 4+ MR at the 30-day follow-up after TAVR, with 104 patients (33.1%) treated with staged TEER (TEER group) and 210 (66.9%) with medical therapy alone. The primary composite outcomes were all-cause mortality and heart failure hospitalization at 2 years. Additional analysis, including changes in MR grade and the New York Association functional classification, and subgroup outcome comparisons based on MR etiology were also conducted. In our study, the rate of primary composite outcome was lower in the TEER group than in the medical therapy alone group (33.7% vs 48.1%, p = 0.015). Significant improvement in MR grade and New York Association class was observed in the TEER group after 2 years. The subgroup analysis demonstrated that in patients with degenerative MR, a lower incidence of composite outcome and heart failure hospitalization was observed in the TEER group (hazard ratio 0.35, 95% confidence interval 0.23 to 0.53, p <0.001). In conclusion, staged TEER after TAVR was associated with reduced MR and improved clinical outcomes. The clinical significance of MR after TAVR should be carefully evaluated, and TEER should be considered for patients with significant residual MR, particularly, those with degenerative MR.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Insuficiencia de la Válvula Mitral/cirugía , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Anciano , Estudios de Seguimiento , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Insuficiencia Cardíaca , Factores de Tiempo
9.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Anciano , Estudios Prospectivos , Estenosis de la Válvula Aórtica/cirugía , Falla de Prótesis , Diseño de Prótesis , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Oclusión Coronaria/cirugía , Complicaciones Posoperatorias/epidemiología
10.
Front Cardiovasc Med ; 11: 1374078, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38566964

RESUMEN

Introduction: Paravalvular leak (PVL) is a severe complication of transcatheter aortic valve replacement (TAVR) that can lead to poor outcomes. TAVR-in-TAVR is a promising treatment for PVL; however, reports on its safety or efficacy are limited. In this study, we aimed to investigate the clinical outcomes of TAVR-in-TAVR using balloon-expandable prostheses for PVLs after TAVR. Methods: We retrospectively analyzed data from patients who underwent TAVR-in-TAVR using balloon-expandable Sapien prostheses for PVL after an initial TAVR at our institution. The procedural success, in-hospital complications, all-cause mortality, and echocardiographic data for up to 2 years post-surgery were evaluated. Results: In total, 31 patients with a mean age of 81.1 ± 7.9 years and mean Society of Thoracic Surgeons score of 8.8 ± 5.4% were identified. The procedural success rate of TAVR-in-TAVR was 96.8% (30/31). No in-hospital deaths, cardiac tamponade, or conversion to sternotomy occurred. Re-intervention was performed in only one patient (3.2%) during hospitalization. The all-cause mortality rates at 30 days and 2 years were 0% and 16.1%, respectively. A significant reduction in the PVL rate was observed at 30 days compared with that at baseline (p < 0.01). Discussion: Our findings suggest that TAVR-in-TAVR using balloon-expandable prostheses is safe and effective for PVL after TAVR with low complication rates and acceptable long-term outcomes. Further studies with larger sample sizes are needed to confirm our findings.

11.
J Surg Res ; 295: 385-392, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38070251

RESUMEN

INTRODUCTION: The membranous septum (MS) length measured by cardiac computed tomography (CT) is useful for the prediction of permanent pacemaker implantation (PPMI) and new left bundle branch block (LBBB) after transcatheter aortic valve replacement. However, its predictive value for patients undergoing surgical aortic valve replacement (SAVR) is unknown. METHODS: A total of 2531 consecutive patients were registered in the institutional Society of Thoracic Surgeons database between July 2017 and June 2020. Patients who underwent non-SAVR procedures, had prior pacemaker/implantable cardioverter defibrillator, prior SAVR, no preprocedural CT assessment, or suboptimal CT imaging were excluded. RESULTS: A total of 126 SAVR with preprocedural CT assessment were analyzed. Bicuspid aortic valve morphology was confirmed on CT in 59.5% of patients. There were three new PPMIs and five new LBBBs observed after SAVR at the time of discharge. In-hospital mortality was 0.8%. Low left ventricular (LV) ejection fraction (<50%), LV mass index >120 g/m2, large right coronary artery height, and MS length <1.5 mm predicted new PPMI/LBBB. Multivariate analysis showed LV mass index >120 g/m2 (odds ratio: 9.165; 95% confidence interval: 1.644-51.080; P = 0.011) and MS length <1.5 mm (odds ratio: 14.449; 95% confidence interval: 1.632-127.954; P = 0.016) were independent predictors for new PPMI/LBBB. CONCLUSIONS: Short MS length on preoperative cardiac CT is a powerful and novel predictor for the risk of new PPMI/LBBB after SAVR. Special care should be taken in patients with short MS length to avoid suture-mediated trauma.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Arritmias Cardíacas , Bloqueo de Rama/terapia
12.
JACC Case Rep ; 23: 101992, 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37954954

RESUMEN

Coronary artery obstruction caused by sinus sequestration is well described after transcatheter aortic valve implantation in failed bioprosthetic valves, which usually occurs during or shortly after the transcatheter aortic valve implantation procedure. We report the presentation, management, and outcomes of 2 cases of very late sinus sequestration in native aortic annuli, which has not been described before to our knowledge. (Level of Difficulty: Advanced.).

13.
Circ Cardiovasc Interv ; 16(11): e012966, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37988437

RESUMEN

Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Reintervention for failed transcatheter heart valves will likely increase in the future as younger patients are expected to outlive the initial bioprosthesis. While redo-TAVR has emerged as an attractive and less invasive alternative to surgical explantation (TAVR-explant) to treat transcatheter heart valve failure, it may not be feasible in all patients due to the risk of coronary obstruction and impaired coronary access. Conversely, TAVR-explant can be offered to most patients who are surgical candidates, but the reported outcomes have shown high mortality and morbidity. This review provides the latest evidence, current challenges, and future directions on redo-TAVR and TAVR-explant for transcatheter heart valve failure, to guide aortic valve reintervention and facilitate patients' lifetime management of aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
14.
Am J Cardiol ; 207: 380-389, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37778227

RESUMEN

Few studies have compared the clinical outcomes between valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) with new-generation valves and re-operative surgical aortic valve replacement (Redo-SAVR). We compared the clinical outcomes of patients who underwent ViV-TAVR with those of patients who underwent Redo-SAVR at Cedars-Sinai Medical Center between 2015 and 2021. New-generation valves were used for ViV-TAVR. A propensity score-matched (PSM) analysis was performed to adjust for differences in baseline characteristics. The primary end point was all-cause mortality at 30 days and 2 years. In-hospital procedural and clinical outcomes were also compared between the groups. A total of 256 patients (140 who underwent ViV-TAVR and 116 who underwent Redo-SAVR) were eligible for PSM. In the unmatched cohort, patients in the ViV-TAVR group were older and had more co-morbidities than those in the Redo-SAVR group. After PSM, there were no significant differences in all-cause death between the ViV-TAVR and Redo-SAVR groups at 30 days (3.9% vs 2.6%, p = 0.65) or 2 years (6.5% vs 7.8%, p = 0.75). The incidences of stroke and heart failure rehospitalization were similar at 30 days and 2 years. The cumulative complication rates during hospitalization were significantly lower in the ViV-TAVR group than in the Redo-SAVR group (11.7% vs 28.6% p = 0.015). The long-term outcomes of ViV-TAVR using new-generation valves were similar to those of Redo-SAVR, although ViV-TAVR was associated with lower rates of in-hospital complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Reoperación , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Factores de Riesgo
15.
Am J Cardiol ; 208: 101-110, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37827014

RESUMEN

Multidetector computed tomography (MDCT) can provide valuable information for mitral assessment, but its role in transcatheter mitral edge-to-edge repair (TEER) planning has been poorly elucidated. We aimed to compare MDCT with 3-dimensional transesophageal echocardiography (3D-TEE) for TEER preprocedural evaluation. We analyzed the preprocedural MDCT and 3D-TEE of 108 consecutive patients with mitral regurgitation (MR) who underwent MitraClip implantation. The levels of agreement for the etiology and mechanism of MR, mitral calcification, mitral annulus, and mitral valve orifice area (MVOA) measurements were compared between MDCT and 3D-TEE data. Receiver-operating-characteristic curves were generated for mitral annulus area and MVOA using a low mean transmitral pressure gradient at discharge (<5 mm Hg) as the state variable, and the primary outcome of all-cause mortality or rehospitalization for heart failure at 1 year was compared between MDCT's and 3D-TEE's MVOA <4-cm2 cutoff. Good levels of agreement between MDCT and 3D-TEE were observed for determining the etiology (κ = 0.81) and mechanism (κ = 0.62) of MR but not for grading mitral calcification (κ = 0.31 to 0.35). The correlations between MDCT and 3D-TEE measurements were strong for mitral annulus area (r = 0.90) and good for MVOA (r = 0.73). Furthermore, no significant differences in the area under the receiver-operating-characteristic curve to predict low transmitral pressure gradient at discharge or the primary outcome at 1 year were detected between MDCT- and 3D-TEE-derived parameters (all p >0.05). In conclusion, in patients who underwent TEER with MitraClip, a high degree of agreement for comprehensive evaluation of MR and prediction of clinical outcomes between MDCT and 3D-TEE was observed.


Asunto(s)
Calcinosis , Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Tomografía Computarizada Multidetector , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Resultado del Tratamiento
16.
Front Cardiovasc Med ; 10: 1249604, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37868777

RESUMEN

Introduction: Transcatheter aortic valve intervention (TAVR) has emerged as a promising alternative to surgical aortic valve replacement for patients with severe aortic stenosis. However, leaflet thrombosis has raised concerns about the long-term durability and outcomes of TAVR. This study aims to provide an overview of the mechanisms, prevention strategies, and treatment options for leaflet thrombosis in TAVR. Clinical evidence: Leaflet thrombosis refers to the formation of blood clots on bioprosthetic valve leaflets, leading to impaired leaflet mobility, early valve degeneration and dysfunction, and potential clinical implications. While the mechanisms underlying thrombus formation on valve leaflets are not fully understood, several factors, such as altered blood flow patterns within valve neosinuses, prothrombotic surfaces, and patient-related causes, have been implicated. Two distinct entities have been identified, namely, hypoattenuated leaflet thickening and restricted leaflet motion. Their occurrence appears dynamic over time and is related to the valve type. Imaging, including transesophageal echocardiography and multidetector computed tomography, plays a crucial role in the diagnosis and follow-up of leaflet thrombosis. Prevention and treatment options: Preventing leaflet thrombosis requires a comprehensive and tailored approach involving identifying high-risk patients, close monitoring, and antithrombotic therapy. Antithrombotic therapy with dual antiplatelet agents or anticoagulation is commonly employed in TAVR patients, although the optimal regimen is yet to be defined. Novel antithrombotic agents, such as direct oral anticoagulants, are being investigated for their efficacy and safety in preventing leaflet thrombosis. When leaflet thrombosis is detected, treatment options include intensified antithrombotic therapy, valve-in-valve intervention, or balloon valvuloplasty. The long-term outcomes and impact of leaflet thrombosis on valve durability and patient prognosis are areas of ongoing research. Summary: Leaflet thrombosis in TAVR is a considerable complication affecting valve function and patient outcomes. Understanding the mechanisms underlying thrombus formation and implementing appropriate prevention strategies are essential for mitigating this risk. Treatment options aim to restore leaflet mobility and optimize valve performance. Further research is needed to establish standardized protocols for antithrombotic therapy, identify high-risk patient populations, and determine the long-term consequences of leaflet thrombosis on TAVR outcomes.

17.
JACC Cardiovasc Interv ; 16(16): 2018-2020, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480888
18.
Front Cardiovasc Med ; 10: 1167212, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37485260

RESUMEN

Objective: Design a predictive risk model for minimizing iliofemoral vascular complications (IVC) in a contemporary era of transfemoral-transcatheter aortic valve replacement (TF-TAVR). Background: IVC remains a common complication of TF-TAVR despite the technological improvement in the new-generation transcatheter systems (NGTS) and enclosed poor outcomes and quality of life. Currently, there is no accepted tool to assess the IVC risk for calcified and tortuous vessels. Methods: We reconstructed CT images of 516 propensity-matched TF-TAVR patients using the NGTS to design a predictive anatomical model for IVC and validated it on a new cohort of 609 patients. Age, sex, peripheral artery disease, valve size, and type were used to balance the matched cohort. Results: IVC occurred in 214 (7.2%) patients. Sheath size (p = 0.02), the sum of angles (SOA) (p < .0001), number of curves (NOC) (p < .0001), minimal lumen diameter (MLD) (p < .001), and sheath-to-femoral artery diameter ratio (SFAR) (p = 0.012) were significant predictors for IVC. An indexed risk score (CSI) consisting of multiplying the SOA and NOC divided by the MLD showed 84.3% sensitivity and 96.8% specificity, when set to >100, in predicting IVC (C-stat 0.936, 95% CI 0.911-0.959, p < 0.001). Adding SFAR > 1.00 in a tree model increased the overall accuracy to 97.7%. In the validation cohort, the model predicted 89.5% of the IVC cases with an overall 89.5% sensitivity, 98.9% specificity, and 94.2% accuracy (C-stat 0.842, 95% CI 0.904-0.980, p < .0001). Conclusion: Our CT-based validated-model is the most accurate and easy-to-use tool assessing IVC risk and should be used for calcified and tortuous vessels in preprocedural planning.

19.
JACC Cardiovasc Interv ; 16(5): 542-554, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36922040

RESUMEN

BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve replacement is indicated in patients undergoing repeat intervention for degenerative aortic valve bioprostheses. Patients with internally stented valves (ie, Mitroflow and Trifecta) are at high risk for coronary artery obstruction during ViV procedures because of valve design, as the leaflets are mounted outside the valve stent. OBJECTIVES: The aim of this study was to compare the hemodynamic and clinical outcomes of transcatheter aortic valve replacement within internally stented valves (ViV-IS) vs other surgical valves (ViV-OS). METHODS: Baseline characteristics, hemodynamic parameters, and clinical outcomes of patients who underwent ViV-IS were retrospectively collected and compared with those of patients who underwent ViV-OS. RESULTS: A total of 250 patients (65% men, median Society of Thoracic Surgeons score 4.4% [IQR: 2.2%-8.4%]) were included. Seventy-one patients (28%) underwent ViV-IS, and 179 (72%) patients underwent ViV-OS. Patients who underwent ViV-OS had better periprocedural hemodynamic status compared with those who underwent ViV-IS (median mean gradient 6 [IQR: 2-13] vs 12 [IQR: 6-16]; P < 0.001). This was not significantly different when both groups were matched on the basis of age, sex, and valve internal diameter size (median mean gradient: 18 [IQR: 13-25] for ViV-OS vs 18 [IQR: 11-24] for ViV-IS; P = 0.36). Coronary protection for potential occlusion was performed more in ViV-IS vs ViV-OS pr (79% vs 6%, respectively; P < 0.001). Patients who underwent ViV-IS had a higher risk for coronary occlusion, requiring stent deployment, compared with those who underwent ViV-OS (54% vs 3%, respectively; P < 0.001. There was no difference in mortality at 3 years between the 2 groups (P = 0.59). CONCLUSIONS: Patients who underwent ViV-IS had a very high incidence of coronary compromise that can be safely and effectively treated. In the setting of a systematic coronary protection strategy, ViV-OS and ViV-IS provide similar mid-term outcome, and periprocedural hemodynamic status (following adjustment for age, sex, and true internal diameter).


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Falla de Prótesis , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Stents , Bioprótesis/efectos adversos , Oclusión Coronaria/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
20.
Front Cardiovasc Med ; 10: 978394, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36760563

RESUMEN

Background: Limited data exist on the use of temporary permanent pacemaker (TPPM) to reduce unnecessary PPM in patients with high-degree atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR). Objectives: This study aims to determine the feasibility of TPPM in patients with HAVB after TAVR to provide prolonged pacing as a bridge. Materials and methods: One hundred and eleven consecutive patients undergoing TAVR were screened from August 2021 to June 2022. Patients with HAVB eligible for PPM were included. TPPM were used in these patients instead of conventional temporary pacing or early PPM. Patients were followed up for 1 month. Holter and pacemaker interrogation were used to determine whether to implant PPM. Results: Twenty one patients met the inclusion criteria for TPPM, of which 14 patients were third-degree AVB, 1 patient was second-degree AVB, 6 patients were first degree AVB with PR interval > 240 ms and LBBB with QRS duration > 150 ms. TPPM were placed on the 21 patients for 35 ± 7 days. Among 15 patients with HAVB, 26.7% of them (n = 4) recovered to sinus rhythm; 46.7% (n = 7) recovered to sinus rhythm with bundle branch block. The remains of 26.7% patients (n = 4) still had third-degree AVB and received PPM. For patients with first-degree AVB and LBBB, PR interval shortened to < 200 ms in all 6 patients and LBBB recovered in 2 patients. TPPM were successfully removed from all patients and no procedure-related adverse events occurred. Conclusion: TPPM is reliable and safe in the small sample of patients with conduction block after TAVR to provide certain buffer time to distinguish whether a PPM is necessary. Future studies with larger sample are needed for further validation of the current results.