1.
Appl Opt ; 46(19): 3969-75, 2007 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-17571133

RESUMEN

A high-resolution liquid-nitrogen-free mid-infrared tunable diode laser absorption spectroscopy (TDLAS) system was used to perform real-time measurement of acetaldehyde concentrations in human exhaled breath following ingestion of an alcoholic beverage. Acetaldehyde absorption features were measured near 5.79 mum (1727 cm(-1)) using a IV-VI semiconductor laser, a 100 m long path optical gas cell, and second- harmonic detection coupled with wavelength modulation. Acetaldehyde levels were measured with a minimum detection limit of 80 ppb for 5 s integration time. The variations in exhaled acetaldehyde levels over time were analyzed prior to and following ingestion of two different amounts of white wine. A method to calibrate acetaldehyde measurements internally using water vapor absorption lines was investigated to eliminate the need for system calibration with gas standards. The potential of a TDLAS system to be used as a noninvasive clinical tool for measurements of large volatile compounds with possible applications in cancer detection is demonstrated.


Asunto(s)
Acetaldehído/análisis , Pruebas Respiratorias , Óptica y Fotónica , Espectrofotometría , Absorción , Acetaldehído/química , Calibración , Gases , Humanos , Rayos Láser , Modelos Teóricos , Espectrofotometría Infrarroja , Factores de Tiempo , Agua/química
2.
Appl Opt ; 41(28): 6018-29, 2002 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-12371564

RESUMEN

We used a high-resolution mid-IR tunable-laser absorption spectroscopy (TLAS) system with a single IV-VI laser operating near 5.2 microm to measure the level of exhaled nitric oxide (eNO) in human breath. A method of internal calibration using simultaneous eNO and exhaled CO2 measurements eliminated the need for system calibration with gas standards. The results observed from internally calibrating the instrument for eNO measurements were compared with measurements of eNO calibrated to gas standards and were found to be similar. Various parameters of the TLAS system for eNO breath testing were examined and include gas cell pressure, exhalation time, and ambient NO concentrations. A reduction in eNO from elevated concentrations (approximately 44 parts in 10(9)) to near-normal levels (<20 parts in 10(9)) from an asthmatic patient was observed after the patient had received treatment with an inhaled glucocorticoid anti-inflammatory medication. Such measurements can help in evaluating airway inflammation and in monitoring the effectiveness of anti-inflammatory therapies.


Asunto(s)
Asma/fisiopatología , Pruebas Respiratorias/instrumentación , Pruebas Respiratorias/métodos , Rayos Láser , Óxido Nítrico , Absorción , Dióxido de Carbono , Humanos , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA