RESUMEN
PURPOSE: To perform a systematic review and meta-analysis of published literature investigating the use of lung ultrasound (LUS) on COVID-19 patients, in emergency point of care settings, and to determine its diagnostic value compared with lung computed tomography (LCT) diagnostic performance. Whilst using the real-time polymerase chain reaction test as the 'gold standard'. METHODS: Literature searches were performed on MEDLINE, Embase, Web of Science, and PubMed databases for eligible studies. The LUS and LCT pooled diagnostic performance were measured using DerSimonian-Laird random effect method. RESULT: Out of a total of 158 studies, 16 met the eligibility criteria and were included in this review. The pooled sensitivity, specificity, positive and negative likelihood ratios were 86.9%, 62.4%, 2.4 and 0.19, respectively for LUS and 93.5%, 72.6%, 3.3 and 0.05, respectively for LCT. CONCLUSION: The lung ultrasound (LUS) demonstrated acceptable sensitivity but poor specificity when used independently to diagnose COVID-19 pneumonia patients in emergency departments, while the lung computed tomography showed higher performance. Thus, LUS can be used to supplement existing diagnostic tools and possibly for the triage of patients.