Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Health Promot Perspect ; 8(4): 268-274, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30479980

RESUMEN

Background: The purpose of this study was to assess the contrast perception of obstacles in a tunnel entrance which was placed in Ilam Province, Iran. Methods: An obstacle with the reflection coefficient of 20% was mounted at the entrance of thetunnel and then, the car was placed near the tunnel entrance and the intrinsic luminance of the road (Lr,intrinsic) and obstacle (Lo,intrinsic) were measured inside the car using the luminance meter. Results: Intrinsic luminance of obstacle and road at the entrance of the tunnel were measured as 41 and 17 cd/m2, respectively. The contrast perception of obstacle in deriver's eyes and in the safe stopping distance (SSD) from the tunnel entrance was determined as 2.79 cd/m2. At the entrance of the studied tunnel, the contrast perception of obstacles with the reflection coefficient of 20% was lower than the minimum contrast perception (28%) recommended by International Commission on Illumination. Conclusion: The main conclusion that can be drawn from it, is that this obstacle in the SSD from the tunnel entrance cannot be conceived by the drivers, which may lead to higher rate of road traffic crashes.

2.
Saf Health Work ; 8(2): 151-155, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28593070

RESUMEN

BACKGROUND: At the entrance of a tunnel, reflection of sunlight from the surrounding environment and a lack of adequate lighting usually cause some vision problems. The purpose of this study was to perform a safety evaluation of lighting on a very long road in Ilam, Iran. METHODS: The average luminance was measured using a luminance meter (model S3; Hagner, Solna, Sweden). A camera (model 108, 35-mm single-lens reflex; Yashica, Nagano, Japan) was used to take photographs of the safe stopping distance from the tunnel entrance. Equivalent luminance was determined according to the Holliday polar diagram. RESULTS: Considering the average luminance at the tunnel entrance (116.7 cd/m2) and using Adrian's equation, the safe level of lighting at the entrance of the tunnel was determined to be 0.7. CONCLUSION: A comparison between the results of the safe levels of lighting at the entrance of the tunnel and the De Boer scale showed that the phenomenon of black holes is created at the tunnel entrance. This may lead to a misadaptation of the drivers' eyes to the change in luminance level at the entrance of the tunnel, thereby increasing the risk of road accidents in this zone.

3.
J Res Health Sci ; 16(2): 90-5, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27497777

RESUMEN

BACKGROUND: Necessity of evaluating heat stress in the workplace, require validation of indices and selection optimal index. The present study aimed to assess the precision and validity of some heat stress indices and select the optimum index for using in heavy work activities in hot and dry climates. METHODS: It carried out on 184 workers from 40 brick kilns workshops in the city of Qom, central Iran (as representative hot and dry climates). After reviewing the working process and evaluation the activity of workers and the type of work, environmental and physiological parameters according to standards recommended by International Organization for Standardization (ISO) including ISO 7243 and ISO 9886 were measured and indices were calculated. RESULTS: Workers engaged in indoor kiln experienced the highest values of natural wet temperature, dry temperature, globe temperature and relative humidity among studied sections (P<0.05). Indoor workplaces had the higher levels of all environmental parameters than outdoors (P=0.0001), except for air velocity. The wet-bulb globe temperature (WBGT) and heat stress index (HSI) indices had the highest correlation with other physiological parameters among the other heat stress indices. Relationship between WBGT index and carotid artery temperature (r=0.49), skin temperature (r=0.319), and oral temperature (r=0.203) was statistically significant (P=0.006). CONCLUSIONS: Since WBGT index, as the most applicable index for evaluating heat stress in workplaces is approved by ISO, and due to the positive features of WBGT such as ease of measurement and calculation, and with respect to some limitation in application of HSI; WBGT can be introduced as the most valid empirical index of heat stress in the brick workshops.


Asunto(s)
Temperatura Corporal , Monitoreo del Ambiente/métodos , Trastornos de Estrés por Calor/etiología , Calor , Humedad , Enfermedades Profesionales/etiología , Exposición Profesional/efectos adversos , Aire , Arterias Carótidas , Clima , Humanos , Irán , Boca , Reproducibilidad de los Resultados , Piel , Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA