RESUMEN

BACKGROUND: During pulsed field ablation (PFA), relationships between ablation parameters (contact force [CF], number of burst pulses, impedance decrease, and electrode temperature) and lesion size in beating hearts have not been well validated. METHODS: A 7.5F-catheter with a 3.5-mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual-Energy, Biosense Webster, Inc, Irwindale, CA) was connected to a PFA system (TRUPULSE2, Biosense Webster, Inc). In 11 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and the skin patch at 219 sites in left ventricle and right ventricle using 12, 18, and 24 burst pulses with 4 different levels of CF: (1) low (n=57; CF, 4-15g; median, 10g); (2) moderate (n=60; CF, 16-30g; median, 22.5g); (3) high (n=68; CF, 32-65g; median, 40g); and (4) no electrode contact (n=34), 2 mm away from the endocardium. Swine were euthanized 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: All PFA lesions with electrode-myocardium contact were well demarcated with triphenyl tetrazolium chloride staining, demonstrating (1) pale central zone (contraction band necrosis with minimal coagulation necrosis), (2) dark brown zone (contraction band necrosis with hemorrhage), and (3) hyperstained red zone by triphenyl tetrazolium chloride (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). Lesion depth increased significantly with increasing CF and the number of PFA burst pulses. An exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlated lesion depth with high accuracy: R=0.809, P<0.0001, ±1.0-mm accuracy in 128 of 163 (79%) lesions, and ±1.5-mm accuracy in 153 of 163 (94%) lesions. Impedance decrease and electrode temperature were poor predictors of lesion size. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions demonstrate irreversible and reversible lesion boundaries. Electrode-tissue contact is required for effective lesion formation. Lesion depth increases significantly with increasing CF and PFA burst pulses. A new exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlates lesion depth with high accuracy.


Asunto(s)
Ablación por Catéter , Animales , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Porcinos , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Catéteres Cardíacos , Diseño de Equipo , Miocardio/patología , Modelos Animales , Impedancia Eléctrica , Necrosis , Sus scrofa , Temperatura , Factores de Tiempo , Frecuencia Cardíaca
2.
J Cardiovasc Electrophysiol ; 34(12): 2514-2526, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37787013

RESUMEN

BACKGROUND: Obesity is associated with an increased risk of developing recurrent atrial fibrillation (AF) after catheter ablation (CA). However, the current data on weight loss interventions show inconsistent results in preventing the recurrence of AF after CA. METHODS: We conducted a systematic search in MEDLINE and EMBASE to identify studies that reported the outcome of recurrence of AF after CA in obese patients undergoing weight interventions. The subgroup analysis included: (1) Weight loss versus no weight loss, (2) >10% weight loss versus <10% weight loss, (3) <10% weight loss versus no weight loss, (4) Follow-up <12 months, and (5) Follow-up >12 months after CA. Mantel-Haenszel risk ratios with a 95% confidence interval (CI) were calculated using a random effects model and for heterogeneity, I2 statistics were reported. RESULTS: A total of 10 studies (one randomized controlled trial and nine observational studies) comprising 1851 patients were included. The recurrence of AF was numerically reduced in the weight loss group (34.5%) versus no weight loss group (58.2%), but no statistically significant difference was observed (risk ratio [RR] = 0.76; 95% CI: 0.49-1.18, p = .22). However, there was a statistically significant reduction in recurrence of AF with weight loss versus no weight loss at follow-up >12 months after CA (RR = 0.47; 95% CI: 0.32-0.68, p < .0001). At follow-up >12 months after CA, both >10% weight loss versus <10% weight loss (RR = 0.49; 95% CI: 0.31-0.80, p = .004) and <10% weight loss versus no weight loss (RR = 0.39; 95% CI: 0.31-0.49, p < .00001) were associated with a statistically significant reduction in recurrent AF. CONCLUSION: In patients with AF undergoing CA, weight loss is associated with reducing recurrent AF at > 12 months after ablation and these benefits are consistently seen with both >10% and <10% weight loss. The benefits of weight loss in preventing recurrent AF after CA should be examined in larger studies with extended follow-up duration.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Resultado del Tratamiento , Recurrencia , Obesidad/complicaciones , Obesidad/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto
3.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37341446

RESUMEN

BACKGROUND AND AIMS: Colchicine is an anti-inflammatory drug that may prevent post-operative atrial fibrillation (POAF). The effect of this drug has been inconsistently shown in previous clinical trials. We aimed to compare the efficacy and safety of colchicine vs. placebo to prevent POAF in patients undergoing cardiac surgery. METHODS AND RESULTS: A systematic search of EMBASE, MEDLINE, SCOPUS, ClinicalTrials.gov, and the Cochrane Library for randomized controlled trials (RCTs) was conducted from inception till April 2023. The primary outcome was the incidence of POAF after any cardiac surgery. The secondary outcome was the rate of drug discontinuation due to adverse events and adverse gastrointestinal events. Risk ratios (RR) were reported using the Mantel Haenszel method. A total of eight RCTs comprising 1885 patients were included. There was a statistically significant lower risk of developing POAF with colchicine vs. placebo (RR: 0.70; 95% CI: 0.59-0.82; P < 0.01, I2 = 0%), and this effect persisted across different subgroups. There was a significantly higher risk of adverse gastrointestinal events (RR: 2.20; 95% CI: 1.38-3.51; P < 0.01, I2 = 55%) with no difference in the risk of drug discontinuation in patients receiving colchicine vs. placebo (RR: 1.33; 95% CI: 0.93-1.89; P = 0.11, I2 = 0%). CONCLUSION: This meta-analysis of eight RCTs shows that colchicine is effective at preventing POAF, with a significantly higher risk of adverse gastrointestinal events but no difference in the rate of drug discontinuation. Future studies are required to define the optimal duration and dose of colchicine for the prevention of POAF.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Humanos , Colchicina/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Incidencia
4.
J Interv Card Electrophysiol ; 66(9): 1989-2001, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36929367

RESUMEN

BACKGROUND: Multiple randomized controlled trials (RCTs) have compared the success of antero-lateral vs. antero-posterior electrode position for cardioversion of atrial fibrillation (AF). However, due to small sample size and conflicting results of these RCTs, the optimal electrode positioning for successful cardioversion remains uncertain. METHODS: A systematic search of MEDLINE and EMBASE was conducted. Outcomes of interest included overall success of cardioversion with restoration of sinus rhythm, 1st shock success, 2nd shock success, mean shock energy required for successful cardioversion, mean number of shocks required for successful cardioversion, success of cardioversion at high energy (> 150 J) and success of cardioversion at low energy (< 150 J). Mantel-Haenszel risk ratios (RR) with 95% confidence intervals were calculated using random-effects model. RESULTS: A total of 14 RCTs comprising 2445 patients were included. There was no statistically significant difference between two cardioversion approaches in the overall success of cardioversion (RR 1.02; 95% CI [0.97-1.06]; p = 0.43), first shock success (RR 1.14; 95% CI [0.99-1.32]), second shock success (RR 1.08; 95% CI [0.94-1.23]), mean shock energy required (mean difference 6.49; 95% CI [-17.33-30.31], success at high energy > 150 J (RR 1.02; 95% CI [0.92-1.14] and success at low energy < 150 J (RR 1.09; 95% CI [0.97-1.22]). CONCLUSIONS: This meta-analysis of RCTs shows no significant difference in the success of cardioversion between antero-lateral vs. antero-posterior electrode position for cardioversion of AF. Large well-conducted and adequately powered randomized clinical trials are needed to definitively address this question.


Asunto(s)
Fibrilación Atrial , Humanos , Cardioversión Eléctrica/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Electrodos , Oportunidad Relativa , Resultado del Tratamiento
5.
J Interv Card Electrophysiol ; 66(2): 493-506, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36085242

RESUMEN

BACKGROUND: In patients with atrial fibrillation (AF) and stable ischemic heart disease, recent guidelines recommend oral anticoagulant (OAC) monotherapy in preference to OAC + single antiplatelet agent (SAPT) dual therapy. However, these data are based on the results of only two randomized controlled trials (RCTs) and a relatively small group of patients. Thus, the safety and efficacy of this approach may be underpowered to detect a significant difference. We hypothesized that OAC monotherapy will have a reduced risk of bleeding, but similar all-cause mortality and ischemic outcomes as compared to dual therapy (OAC + SAPT). METHODS: A systematic search of PubMed/MEDLINE, EMBASE, and Scopus was conducted. Safety outcomes included total bleeding, major bleeding, and others. Efficacy outcomes included all-cause mortality, cardiovascular mortality, myocardial infarction, stroke, and major adverse cardiovascular events (MACE). RCTs and observational studies were pooled separately (study design stratified meta-analysis). Subgroup analyses were performed for vitamin K antagonists and direct oral anticoagulants (DOACs). Pooled risk ratios (RR) with corresponding 95% confidence intervals (CI) were calculated using the Mantel-Haenszel method. RESULTS: Meta-analysis of 2 RCTs comprising a total of 2905 patients showed that dual therapy (OAC + SAPT) vs. OAC monotherapy was associated with a statistically significant increase in major bleeding (RR 1.51; 95% CI [1.10, 2.06]). There was no significant reduction in MACE (RR 1.10; [0.71, 1.72]), stroke (RR 1.29; [0.85, 1.95]), myocardial infarction (RR 0.57; [0.28, 1.16]), cardiovascular mortality (RR 1.22; [0.63, 2.35]), or all-cause mortality (RR 1.18 [0.52, 2.68]). Meta-analysis of 20 observational studies comprising 47,451 patients showed that dual therapy (OAC + SAPT) vs. OAC monotherapy was associated with a statistically significant higher total bleeding (RR 1.50; [1.20, 1.88]), major bleeding (RR = 1.49; [1.38, 1.61]), gastrointestinal bleeding (RR = 1.62; [1.15, 2.28]), and myocardial infarction (RR = 1.15; [1.05, 1.26]), without significantly lower MACE (RR 1.10; [0.97, 1.24]), stroke (RR 0.93; [0.73, 1.19]), cardiovascular mortality (RR 1.11; [0.95, 1.29]), or all-cause mortality (RR 0.93; [0.78, 1.11]). Subgroup analysis showed similar results for both vitamin K antagonists and DOACs, except a statistically significant higher intracranial bleeding with vitamin K antagonist + SAPT vs. vitamin K antagonist monotherapy (RR 1.89; [1.36-2.63]). CONCLUSIONS: In patients with AF and stable ischemic heart disease, OAC + SAPT as compared to OAC monotherapy is associated with a significant increase in bleeding events without a significant reduction in thrombotic events, cardiovascular mortality, and all-cause mortality.


Asunto(s)
Fibrilación Atrial , Infarto del Miocardio , Isquemia Miocárdica , Accidente Cerebrovascular , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Fibrilación Atrial/diagnóstico , Resultado del Tratamiento , Isquemia Miocárdica/complicaciones , Anticoagulantes/uso terapéutico , Hemorragia/inducido químicamente , Infarto del Miocardio/complicaciones , Fibrinolíticos/efectos adversos , Vitamina K , Administración Oral
6.
Circ Arrhythm Electrophysiol ; 14(10): e009194, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34601885

RESUMEN

In this review, we emphasize the unique value of recording the activation sequence of the His bundle or right bundle branch (RB) for diagnoses of various supraventricular and fascicular tachycardias. A close analysis of the His to RB (H-RB) activation sequence can help differentiate various forms of supraventricular tachycardias, namely atrioventricular nodal reentry tachycardia from concealed nodofascicular tachycardia, a common clinical dilemma. Furthermore, bundle branch reentry tachycardia and fascicular tachycardias often are included in the differential diagnosis of supraventricular tachycardia with aberrancy, and the use of this technique can help the operator make the distinction between supraventricular tachycardias and these other forms of ventricular tachycardias using the His-Purkinje system. We show that this technique is enhanced by the use of multipolar catheters placed to span the proximal His to RB position to record the activation sequence between proximal His potential to the distal RB potential. This allows the operator to fully analyze the activation sequence in sinus rhythm as compared to that during tachycardia and may help target ablation of these arrhythmias. We argue that 3 patterns of H-RB activation are commonly identified-the anterograde H-RB pattern, the retrograde H-RB (right bundle to His bundle) pattern, and the chevron H-RB pattern (simultaneous proximal His and proximal RB activation)-and specific arrhythmias tend to be associated with specific H-RB activation sequences. We show that being able to record and categorize this H-RB relationship can be instrumental to the operator, along with standard pacing maneuvers, to make an arrhythmia diagnosis in complex tachycardia circuits. We highlight the importance of H-RB activation patterns in these complex tachycardias by means of case illustrations from our groups as well as from prior reports.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Taquicardia Paroxística/diagnóstico , Taquicardia Ventricular/diagnóstico , Humanos , Taquicardia Paroxística/fisiopatología , Taquicardia Paroxística/terapia , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia
9.
JACC Clin Electrophysiol ; 6(6): 623-635, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32553211

RESUMEN

OBJECTIVES: This study was designed to evaluate lesion durability on invasive electrophysiologic remapping. BACKGROUND: The lattice-tip catheter generates a large thermal footprint during temperature-controlled irrigated radiofrequency ablation. In a first-in-human study, this catheter performed rapid point-by-point pulmonary vein isolation (PVI) and other linear atrial ablations. METHODS: In a prospective 3-center single-arm study, paroxysmal or persistent atrial fibrillation patients underwent PVI and, as needed, linear ablation at the cavotricuspid isthmus (CTI), mitral isthmus (MI), and/or left atrial roof; no other atrial substrate was ablated. Using the lattice catheter and a custom electroanatomic mapping system, temperature-controlled (Tmax 73° to 80°C; 2 to 7 s) point-by-point ablation was performed. Patients were followed for 12 months. RESULTS: A total of 65 patients (61.5% paroxysmal/38.5% persistent) underwent ablation: PVI in 65, MI in 22, left atrial roof in 24, and CTI in 48 patients. At a median of 108 days after the index procedure, protocol-mandated remapping was performed in 27 patients. The pulmonary veins (PVs) remained durably isolated in all but 1 reconnected PV-translating to durable isolation in 99.1% of PVs, or 96.3% of patients with all PVs isolated. Of 47 linear atrial lesions initially placed during the index procedure, durability was observed in 10 of 11 (90.9%) MI lines, all 11 (100%) roof lines, and all 25 (100%) CTI lines. After a median follow-up of 270 days, the 12-month Kaplan-Meier estimate for freedom from atrial arrhythmias was 94.4 ± 3.2%. CONCLUSIONS: Temperature-controlled lattice-tip point-by-point ablation showed not only highly durable PVI lesion sets, but also durable contiguity of linear atrial lesions.


Asunto(s)
Ablación por Catéter , Venas Pulmonares , Catéteres , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Temperatura
10.
JACC Clin Electrophysiol ; 6(5): 507-519, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32439034

RESUMEN

OBJECTIVES: This study sought to evaluate the safety and acute performance of the lattice tip for the treatment of atrial flutter and fibrillation (AF). BACKGROUND: A novel catheter using an expandable lattice structure with a wide thermal footprint incorporating multiple surface thermocouples/mini-electrodes has been designed for high-resolution mapping and high-current, temperature-controlled radiofrequency ablation (RFA). METHODS: Patients with typical right atrial flutter or AF were prospectively enrolled in a single-arm study at 3 centers. Patients with atrial flutter underwent cavotricuspid isthmus (CTI) ablation. Patients with paroxysmal AF underwent pulmonary vein isolation (PVI) and CTI if desired, and for patients with persistent AF, mitral isthmus and left atrial roof lines were also permitted. Mapping was performed with the lattice (Sphere-9) catheter and a novel compatible electroanatomic mapping system (Prism-1). RFA was performed in a point-by-point fashion (Tmax, 73°C to 80°C; range 2 to 7 s). Patients were followed for 3 months. RESULTS: A total of 71 patients underwent ablation: 65 PVI (38% with persistent AF) and 22 mitral isthmus, 24 roof, and 48 CTI lines. PVI was achieved in 64 of 65 (98.5%) by using the lattice alone and required a mean of 2.7 ± 0.70 RFA min. Mitral block was achieved in 100% by using 11.5 ± 10.7 applications and 1.0 ± 0.92 RFA min; only 1 patient required adjunctive epicardial coronary sinus ablation. Roof line and CTI block were achieved in 95.8% and 100% of patients, using 4.9 ± 1.9 and 5.9 ± 3.1 applications for 0.4 ± 0.16 and 0.5 ± 0.24 RFA min, respectively. At 3 months, there were no deaths, strokes, tamponade, or atrioesophageal fistula. CONCLUSIONS: This first-in-human study demonstrated clinical feasibility and safety for rapid high-current, temperature-controlled point-by-point PVI and linear ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Catéteres , Humanos , Venas Pulmonares/cirugía , Temperatura
11.
JACC Clin Electrophysiol ; 6(3): 282-291, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32192678

RESUMEN

OBJECTIVES: This study was a sham-controlled, double-blind, randomized clinical trial to examine the effect of chronic low level tragus stimulation (LLTS) in patients with paroxysmal AF. BACKGROUND: Low-level transcutaneous electrical stimulation of the auricular branch of the vagus nerve at the tragus (LLTS) acutely suppresses atrial fibrillation (AF) in humans, but the chronic effect remains unknown. METHODS: LLTS (20 Hz, 1 mA below the discomfort threshold) was delivered using an ear clip attached to the tragus (active arm) (n = 26) or the ear lobe (sham control arm) (n = 27) for 1 h daily over 6 months. AF burden over 2-week periods was assessed by noninvasive continuous electrocardiogram monitoring at baseline, 3 months, and 6 months. Five-minute electrocardiography and serum were obtained at each visit to measure heart rate variability and inflammatory cytokines, respectively. RESULTS: Baseline characteristics were balanced between the 2 groups. Adherence to the stimulation protocol (≤4 sessions lost per month) was 75% in the active arm and 83% in the control arm (p > 0.05). At 6 months, the median AF burden was 85% lower in the active arm compared with the control arm (ratio of medians: 0.15; 95% confidence interval: 0.03 to 0.65; p = 0.011). Tumor necrosis factor-alpha was significantly decreased by 23% in the active group relative to the control group (ratio of medians: 0.77; 95% confidence interval: 0.63 to 0.94; p = 0.0093). Frequency domain indices of heart rate variability were significantly altered with active versus control stimulation (p < 0.01). No device-related side effects were observed. CONCLUSIONS: Chronic, intermittent LLTS resulted in lower AF burden than did sham control stimulation, supporting its use to treat paroxysmal AF in selected patients. (Transcutaneous Electrical Vagus Nerve Stimulation to Suppress Atrial Fibrillation [TREAT-AF]; NCT02548754).


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Eléctrica Transcutánea del Nervio/métodos , Anciano , Fibrilación Atrial/fisiopatología , Método Doble Ciego , Oído Externo/fisiología , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nervio Vago/fisiología
12.
Heart Rhythm O2 ; 1(4): 311-314, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34113885

RESUMEN

BACKGROUND: The management of patients with atrial fibrillation and an abnormally fast ventricular response has been through the use of pharmacologic agents. In those cases where rate control cannot be achieved pharmacologically, a standard approach has been atrioventricular (AV) junctional ablation and ventricular pacemaker implantation to achieve a stable ventricular rate. Long-term ventricular pacing has been shown to result in diminished ventricular function that can lead to heart failure. OBJECTIVE: To describe an experimental and clinical study demonstrating a modified form of AV junction ablation. METHODS: Ablation of the slow and fast AV nodal input does not produce AV block. Ablation of the connection between the two induces AV block, leaving the AV node and His bundle intact. RESULTS: Subsequently the escape heart rate is close to normal and responds well to exercise. CONCLUSION: In a clinical study with a 42 month follow-up, the modified procedure resulted in significantly reduced pacemaker dependence and mortality compared to the standard AV ablation procedure.

13.
Circ Arrhythm Electrophysiol ; 11(9): e006631, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30354287

RESUMEN

Background We describe a technique to localize the ablation target in patients with an unusual variant of slow/fast atrioventricular nodal reentrant tachycardia (AVNRT) using a slow pathway connecting to the basal inferolateral left atrium. Methods Consecutive patients with slow/fast AVNRT were included. During stable slow/fast AVNRT, a single late atrial extrastimulus (AES) was delivered at the inferolateral left atrium near the mitral annulus. Advancing the next His bundle potential by ≥5 ms, followed by resetting of the tachycardia cycle length, indicated that the AES engaged the anterograde slow pathway. The latest AES resetting AVNRT was considered to be in close proximity to the atrial end of the anterograde slow pathway and was selected as the ablation target. Results In 10 of 843 (1.2%) patients, ablation at the inferolateral left atrium was required. All patients had had failed ablation at the inferior triangle of Koch and roof of the coronary sinus. In all 10 patients, a late AES advanced the His bundle potential by ≥10 ms and reset the tachycardia. Ablation at that site eliminated slow pathway conduction and terminated the tachycardia. Ablation was successful at the site of the latest AES, delivered 49±12 ms after the onset of the His bundle potential. No recurrent tachycardia was noted at 1 year of follow-up. Conclusions The inferolateral left atrium slow pathway is used in a small subset of patients with slow/fast AVNRT. Accurate localization of the ablation target can be achieved by delivering late AES during AVNRT (resetting response).


Asunto(s)
Fascículo Atrioventricular Accesorio , Potenciales de Acción , Nodo Atrioventricular/fisiopatología , Frecuencia Cardíaca , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Adolescente , Adulto , Anciano , Nodo Atrioventricular/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento