Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Cancer Res Ther ; 19(5): 1261-1266, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37787293

RESUMEN

Objectives: The objective of the study is to analyze the difference in target dose distributions between Acuros XB (AXB) and collapsed cone convolution (CCC)/superposition and the impact of the tumor locations in clinical cases of stereotactic ablative body radiotherapy (SABR) for lung cancer. Materials and Methods: Ninety-six patients underwent SABR for lung cancers Kyushu University Hospital from 2014 to 2017. We recalculated clinical plans originally calculated by AXB using CCC with the identical monitor units (MUs) and beam arrangements. We calculated the following dosimetric parameters: maximum dose (Dmax), minimum dose (Dmin), homogeneity index (HI), conformity index (CI), and D95 of the planning target volume (PTV). We investigated the difference between the results of two calculations and examined the impact of tumor location. Moreover, we determined the target central dose using a thorax phantom and assessed the calculation accuracy of the two algorithms for each fraction. Results: CCC significantly overestimated the dose to PTV, compared to AXB (P < 0.05). The mean differences of Dmax, Dmin, and D95 were 1.17, 1.95, and 1.85 Gy, respectively. The mean differences of HI and CI were 0.02 and - 0.06. Dmin, HI, and D95 had significant correlations with the tumor location, and the difference was greater when the PTV was included the chest wall (P < 0.05). The discrepancy between the calculated and irradiated dose was 2.48% for CCC, whereas it was 0.14% for AXB. Conclusions: We demonstrated that CCC significantly overestimated the dose to PTV relative to AXB in clinical cases of lung SABR.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Neoplasias Pulmonares/patología , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos
2.
Chemistry ; 29(14): e202202702, 2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36520052

RESUMEN

A new class of diamino-substituted π-extended phenazine compound was synthesized, and its photophysical properties were investigated. The U-shaped diaminophenazine displayed photoluminescence in solution with moderate quantum yield. The diamino aromatic compound was found applicable to the poly-condensation with formaldehyde to form Tröger's base ladder polymer. The obtained microporous ladder polymer features high CO2 adsorption selectivity against N2 , most likely due to the presence of basic nitrogen atoms in the phenazine rings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA