Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Transplant Proc ; 45(9): 3229-33, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24182790

RESUMEN

BACKGROUND: Pre-transplantation living-donor kidney function determines remaining donor kidney function and significantly affects post-transplantation allograft function in the recipient. Few transplantation centers perform donor kidney function measurement owing to patient burden. A simplified method of glomerular filtration rate (GFR) measurement after angiographic procedures may facilitate more precise measurement of donor kidney function. METHODS: We evaluated the agreement between a simplified method of GFR measurement after renal computerized tomographic (CT) angiography (index GFR, 100 mL iohexol [350 mg/mL iodine]) and the reference GFR measurement with the use of iodinated radiocontrast media (5 mL bolus of iohexol [300 mg/mL iodine]) among 19 potential living kidney transplant donors. The 24-hour creatinine clearance and GFR estimation equations were additionally examined. Kidney lengths and total and segmented cortical kidney volumes were also measured. RESULTS: The index CT angiography GFR performed best with respect to the reference GFR with minimal bias (mean difference, -4 mL/min/1.73 m(2)), good precision (SD of the difference, 9.8 mL/min/1.73 m(2)), coefficient of determination (R(2)) of 0.74, narrow mean coefficient of variation (5% [range 1%-15%]), and high accuracy, with 100% of the values for the index test within 30% of the reference test. The 24-hour urine creatinine clearance values performed poorly. Kidney volumes and length did not significantly correlate with measured GFR. CONCLUSIONS: The CT angiographic GFR measurement could be a useful and more convenient method of donor kidney function evaluation and maintains minimal bias, high precision, and accuracy compared with the reference GFR measurement.


Asunto(s)
Angiografía/métodos , Tasa de Filtración Glomerular , Yohexol/farmacocinética , Trasplante de Riñón , Riñón/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Humanos , Riñón/fisiología
2.
Fetal Diagn Ther ; 12(4): 241-3, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9354885

RESUMEN

We report 2 cases of fetal heart failure associated with large placental chorioangiomas. One fetus exhibited serious hydrops on the initial fetal echocardiogram and was ultimately stillborn. The fetus in the other case exhibited cardiomegaly. Following the premature termination of the pregnancy, the fetus received medical treatment and recovered in 7 days. Monitoring the fetal cardiac size with ultrasonography is recommended to determine the optimal time of delivery in cases of large placental angioma that are diagnosed prenatally.


Asunto(s)
Enfermedades Fetales/etiología , Cardiopatías/etiología , Hemangioma/complicaciones , Enfermedades Placentarias/complicaciones , Complicaciones Neoplásicas del Embarazo , Aborto Espontáneo/etiología , Adulto , Femenino , Enfermedades Fetales/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Hemangioma/diagnóstico por imagen , Humanos , Recién Nacido , Enfermedades Placentarias/diagnóstico por imagen , Embarazo , Complicaciones Neoplásicas del Embarazo/diagnóstico por imagen , Neoplasias Trofoblásticas , Ultrasonografía Prenatal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA