1.
Front Cardiovasc Med ; 11: 1449038, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39234609

RESUMEN

Background: Despite the high success rate of radiofrequency catheter ablation (RFCA) in Wolff-Parkinson-White Syndrome (WPW), localizing the successful ablation site can be challenging and may require multiple radiofrequency (RF) applications. Objective: This study aims to evaluate the efficacy of a novel workflow for the automatic and precise identification of accessory pathway ablation site, named Delta Wave Automatic Mapping. Methods: Patients undergoing a first procedure for RF ablation of a manifest accessory pathway were included. Electro-Anatomical Mapping (EAM) was performed with the CARTO 3 system (Biosense Webster, Johnson & Johnson Medical S.p.a., Irvine, CA) leveraging auto-acquisition algorithms already present in the CARTO 3 software. Mapping and ablation were performed with an irrigated tip catheter with contact force sensor. Procedure success was defined as loss of pathway function after ablation. The number of RF applications required and time to effect were measured for each patient. Recurrences were evaluated during follow-up visits. Additionally, at the end of each procedure, historical predictors of ablation success were measured offline to evaluate their relationship with the successful ablation site found with the novel workflow. Results: A total of 50 patients were analysed (62% APs right and 38% APs left). All 50 APs were successfully eliminated in each procedure with a median Time-to-effect (TTE) of 2.0 (IQR 1.2-3.5) seconds. No AP recurrences during a median follow-up of 10 (IQR 6-13) months were recorded. Offline analysis of successful ablation site revealed a pre-ablation delta/ventricular interval of ≤-10 msec in 52% of the patients and in 100% of the patients the signal related to the Kent bundle was identified. Conclusions: The novel workflow efficiently localizes APs without requiring manual annotations. Historical endocardial parameters predicting success were measured offline for each case and they corresponded to the ablation target automatically annotated by the proposed workflow. This novel mapping workflow holds promise in enhancing the efficacy of RFCA in the presence of manifest APs.

2.
Heart Rhythm ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39181485

RESUMEN

BACKGROUND: No data have been reported on cooling characteristics and the impact of variant pulmonary vein (PV) anatomy on atrial fibrillation (AF) recurrences after POLARx cryoballoon (CB) ablation. OBJECTIVE: The purpose of this study was to analyze the impact of PV anatomy variants and cooling characteristics after CB ablation from a large multicenter prospective registry. METHODS: The primary end point was defined as 1-year absence of any atrial tachyarrhythmias (ATAs: AF/atrial flutter/atrial tachycardia). Correlation between ATA recurrences and anatomy variants/cooling characteristics were evaluated. The secondary outcome was the rate of major periprocedural complications. RESULTS: A total of 429 consecutive patients diagnosed with paroxysmal AF (83.4%) or persistent AF (peAF; 16.6%) were enrolled. Twenty-eight patients (6.6%) exhibited an anatomical variant (common ostium: 4.0%; adjunctive PV: 2.6%). Nadir temperature, thaw time, and total deflation time were different between standard PVs and PV variants. After the blanking period, over a mean of 431 ± 99 days of follow-up, 63 patients (14.7%) suffered an ATA recurrence. Patients with recurrences had both a shorter thaw time (18.5 ± 7 seconds vs 19.8 ± 7 seconds; P = .0012) and a shorter total deflation time, whereas time to isolation was longer (57.4 ± 42 seconds vs 49.1 ± 33 seconds; P = .04). Patients with anatomy variants showed a similar ATA recurrence rate (5 of 28 [17.9%]) to the standard anatomy group (58 of 401 [14.5%]) (P = .584), with a hazard ratio (HR) of 1.43 (95% confidence interval [CI] 0.49-4.13; log-rank, P = .4384). After adjusting for confounders, heart failure (HR 4.12; 95% CI 1.75-9.73; P = .0013) and peAF (HR 1.81; 95% CI 1.03-3.18; P = .0433) remained associated with ATA recurrence during follow-up. CONCLUSION: The POLARx CB system demonstrated long-term efficacy, along with a safe profile, in both patients with paroxysmal AF and those with peAF, regardless of the presence PV variants. Time to isolation was longer in patients with ATA recurrences during follow-up. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). CLINICALTRIALS: gov identifier: NCT03793998. Registration date: January 4, 2019.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39072776

RESUMEN

BACKGROUND: The programing of subcutaneous implantable cardioverter-defibrillators (S-ICD) in clinical practice has been little studied, as the activation status of the SMART Pass filter, which was implemented to reduce inappropriate shocks. PURPOSE: We assessed device programing during follow-up and the rate of detected arrhythmias in consecutive S-ICD recipients. METHODS: We analyzed data from 670 S-ICD patients followed on the remote network at 17 Italian centers for a median of 31 months (25th-75th percentile: 16-51). The enhanced SMART Pass version, introduced in October 2022, was expected to reduce the unintentional deactivation rate. RESULTS: At the latest remote data transmission, the median conditional zone cut-off was set to 210 bpm (25th-75th percentile: 200-220), the shock zone cutoff was 250 bpm (25th-75th percentile: 240-250), and the SMART Pass was enabled in 586 (87%) patients. During follow-up, 194 automatic deactivation events were reported in 118 (18%) patients. Shocks were delivered in 129 (19%) patients, and untreated arrhythmias were recorded in 136 (20%) patients. The rate of shocks was lower when SMART Pass was enabled -0.12/patient-year (95% CI: 0.10-0.14) versus 0.20 (95% CI: 0.15-0.26) (p = .002), as it was the rate of untreated arrhythmias -0.12/patient-year (95% CI: 0.11-0.14) versus 0.23 (95% CI: 0.18-0.30) (p = .001). The enhanced SMART Pass version was associated with a lower rate of deactivations -0.04/patient-year (95% CI: 0.02-0.05) versus 0.14 (95% CI: 0.12-0.16) (p < .001), and with a reduction in treated and untreated arrhythmias (Incidence rate ratios: 0.40 (95% CI: 0.28-0.53) and 0.40 (95% CI: 0.30-0.55), respectively (p < .001)). CONCLUSIONS: Centers tend to program devices to detect high ventricular rates for arrhythmia detection, to minimize inappropriate shock occurrences. SMART Pass activation is associated with lower rates of detected and treated arrhythmias. The enhanced SMART Pass version seems associated with a lower deactivation rate and with a further decrease in treated arrhythmias.

4.
Pacing Clin Electrophysiol ; 47(8): 983-987, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38963722

RESUMEN

INTRODUCTION: Patients with Brugada syndrome (BrS) face an increased risk of ventricular arrhythmias and sudden cardiac death. Implantable cardiac monitors (ICMs) have emerged as effective tools for detecting arrhythmias in BrS. Technological advancements, including temperature sensors and improved subcutaneous electrocardiogram (subECG) signal quality, hold promise for further enhancing their utility in this population. METHODS AND RESULTS: We present a case of a 40-year-old man exhibiting a BrS type 2 pattern on 12-lead ECG, who underwent ICM insertion (BIOMONITOR IIIm, BIOTRONIK) due to drug-induced BrS type 1 pattern and a history of syncope, with a negative response to programmed ventricular stimulation. The device contains an integrated temperature sensor and can transmit daily vital data, such as mean heart rate and physical activity. Several months later, remote alerts indicated a temperature increase, along with transmitted subECGs suggesting a fever-induced BrS type 1 pattern. The patient was promptly advised to commence antipyretic therapy. Over the following days, remotely monitored parameters showed decreases in mean temperature, physical activity, and mean heart rate, without further recurrence of abnormal subECGs. CONCLUSION: ICMs offer valuable insights beyond arrhythmia detection in BrS. Early detection of fever using embedded temperature sensors may improve patient management, while continuous subECG morphological analysis has the potential to enhance risk stratification in BrS patients.


Asunto(s)
Síndrome de Brugada , Humanos , Síndrome de Brugada/fisiopatología , Masculino , Adulto , Electrocardiografía Ambulatoria/instrumentación , Temperatura Corporal , Tecnología de Sensores Remotos/instrumentación , Electrocardiografía , Diseño de Equipo
5.
Heart Rhythm ; 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38878939

RESUMEN

BACKGROUND: Advances in leadless pacemaker technology have enabled accelerometer-based atrioventricular (AV) synchronous pacing by sensing atrial mechanical contraction. OBJECTIVE: The purpose of this study was to report the performance of the Micra AV leadless pacemaker from the worldwide Micra AV post-approval registry (PAR) through 12 months. METHODS: The Micra AV PAR is a prospective, single-arm, observational registry designed to assess the safety and effectiveness of Micra AV in a real-world setting. For the present interim analysis, major complications and system revisions through 12 months were summarized and compared to a historical cohort of 2667 patients implanted with a transvenous dual-chamber pacing system. RESULTS: The device was successfully implanted in 796 of 801 patients (99.4%) at 97 centers in 19 countries. Micra AV patients were older (74.1 years vs 71.1 years; P < .0001) with a higher incidence of renal disease (22.3% vs 9.8%; P < .0001) compared with transvenous dual-chamber patients. Through 12 months, the major complication rate was 3.7% in Micra AV patients compared with 8.8% in transvenous dual-chamber patients (hazard ratio 0.42; 95% confidence interval 0.28-0.61; P < .001). The system revision rate was 1.5% in Micra AV patients compared with 5.5% for transvenous dual-chamber patients (hazard ratio 0.25; 95% confidence interval 0.13-0.47; P < .001); this reduction was largely driven by the absence of lead dislodgments requiring revision. The median AV synchrony index was 79.4% (interquartile range 65.2%-86.4%) in patients paced >90%. CONCLUSION: The Micra AV leadless pacemaker was implanted with a high rate of success in patients with multiple comorbidities, with a significantly lower rate of complications and system revisions through 12 months compared to a historical cohort of patients with transvenous dual-chamber pacemakers.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38923783

RESUMEN

INTRODUCTION: The dST-Tiso is a newly proposed electrocardiographic (ECG) marker during Brugada (BrS) type I pattern, that predicts the likelihood of ventricular arrhythmia (VA) inducibility in patients with ajmaline-induced pattern. The objective of this study was to validate the effectiveness of this criterion using an independent data set. METHODS: Consecutive patients exhibiting a BrS type I ECG pattern following ajmaline administration underwent programmed ventricular stimulation (PVS). dST-Tiso interval was measured in all patients and tested as a predictor for positive VA inducibility. RESULTS: Among 128 patients (median age 43 years, 59% male) with drug-induced BrS type I ECG pattern who underwent PVS, 32 (25.0%) had VA inducibility that required defibrillation. Compared to noninducible subjects, those with positive PVS were more commonly male (81% vs. 51%, p = 0.003), had longer PQ (165 vs. 160 ms, p = 0.016) and dST-Tiso (310 vs. 230 ms, p < 0.001) intervals, and shorter QT interval (412 vs. 420 ms, p = 0.022). When treated as a continuous variable, dST-Tiso confirmed significant association with VA inducibility, with an adjusted odds ratio of 1.02 (95% confidence interval: 1.01-1.03, p < 0.001) for each 1 ms increase in duration. A dST-Tiso interval >300 ms yielded a sensitivity of 75%, a specificity of 86%, and positive and negative predictive values of 69% and 91%, respectively. CONCLUSION: The validation of the model based on the dST-Tiso interval >300 ms confirmed its high accuracy in predicting VA inducibility in drug-induced BrS type I pattern. This straightforward ECG marker might be linked to the extent of the electrical substrate of the disease.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38814525

RESUMEN

BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.

9.
Heart Rhythm ; 21(9): 1630-1639, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38493989

RESUMEN

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Anciano , Incidencia , Progresión de la Enfermedad , Medición de Riesgo/métodos , Atrios Cardíacos/fisiopatología , Marcapaso Artificial , Frecuencia Cardíaca/fisiología , Factores de Riesgo , Persona de Mediana Edad , Tecnología de Sensores Remotos/instrumentación , Estudios de Seguimiento
10.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519418

RESUMEN

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Anciano , Estudios Prospectivos , Factores de Tiempo , Italia , Factores de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Supervivencia sin Progresión
11.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38449430

RESUMEN

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Arritmias Cardíacas/terapia , Frecuencia Cardíaca/fisiología
12.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38448797

RESUMEN

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Lesiones Cardíacas , Venas Pulmonares , Humanos , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Lesiones Cardíacas/etiología , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
13.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38426911

RESUMEN

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Sistema de Registros , Estimulación Cardíaca Artificial/efectos adversos
14.
Front Cardiovasc Med ; 11: 1304404, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38333419

RESUMEN

Introduction: It has recently been shown that electrocardiographic imaging (ECGi) can be employed in individuals undergoing an ajmaline test who have Brugada Syndrome (BrS), to evaluate the extent of substrate-involved arrhythmia in the right ventricular overflow tract (RVOT). For the first time, we stratify the risk of sudden cardiac death (SCD) in BrS during ajmaline testing using the dST-Tiso interval (a robust predictor of the inducibility of ventricular arrhythmias (VAs) in the presence of drug-induced BrS type-1 pattern) in combination with ECGi technology. Case presentation: We studied a 48-year-old man with BrS ECG type-2 pattern and presence of J-wave without a family history of SCD but with a previous syncope. Transthoracic echocardiography and cardiac magnetic resonance imaging were performed, showing normal results. The ECG was performed to assess the novel ECG marker "dST-Tiso interval." The 3D epicardial mapping of the RVOT surface was performed with the support of a non-contact cardiac mapping system in sinus rhythm during ajmaline infusion. The examination of the propagation map unveiled the presence of multiple conduction blocks in this pathologic epicardial region, and the conduction blocks were identified within the central part and/or near the boundary separating the normal and slow conduction areas. Conclusion: The dST-Tiso interval, which lies between the onset and termination of the coved ST-segment elevation and serves as a robust predictor of VA inducibility in cases of drug-induced BrS type-1 pattern, was utilized in conjunction with ECGi technology (employed for the non-invasive confirmation and identification of the pathological substrate area). This combined approach was applied to stratify the risk of SCD in BrS during ajmaline testing, alongside clinical scores.

15.
Heart Rhythm ; 21(6): 780-787, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38290688

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Nervio Vago , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Masculino , Femenino , Ablación por Catéter/métodos , Persona de Mediana Edad , Frecuencia Cardíaca/fisiología , Nervio Vago/fisiopatología , Nervio Vago/fisiología , Estudios Prospectivos , Sistema de Conducción Cardíaco/fisiopatología , Anciano , Resultado del Tratamiento , Ganglios Autónomos/fisiopatología , Ganglios Autónomos/cirugía , Estudios de Seguimiento
16.
J Interv Card Electrophysiol ; 67(3): 609-616, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37697222

RESUMEN

BACKGROUND: The aims of this analysis were: to evaluate the impact of timing of ablation on the rate of atrial arrhythmias recurrence, verify if the timing of ablation impact differently in patients with paroxysmal and persistent AF. METHODS: Three thousand two hundred and five patients (60.5 ± 10 years, female 28.4%%, 78.8%% paroxysmal AF) were included in the analysis. All patients underwent only cryoballoon (CB) pulmonary vein (PV) isolation during the index procedure. RESULTS: The mean procedure time was 102.8 ± 50 min, with a mean fluoroscopy time of 26.3 ± 49 min. Acute PV isolation was achieved in 11760/11793 (99.7%) PVs. A total of 91 (2.8%) patients experienced a procedure-related complication. During the observation period 913/3205 (28.5%) patients had at least one atrial arrhythmias episode: 28% of patients with paroxysmal AF vs 33% of patients with persistent AF. In multivariate analysis, persistent AF together with time from symptomatic AF diagnosis to ablation, female sex, and ablation time showed to be significant predictors for AF recurrence. In particular, months from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence (HR = 1.23, 95% CI = 1.03-1.46, p = 0.020). In patients with paroxysmal AF, the multivariate analysis confirmed that months from first symptomatic AF episode > 18 month was an independent predictor of AF recurrence together with age > 62 years and female sex. In patients with persistent AF, the time from persistent AF showed to be significant predictor for AF recurrence. CONCLUSIONS: In this multicenter analysis, time from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence after CB PV isolation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Resultado del Tratamiento , Venas Pulmonares/cirugía , Criocirugía/métodos , Factores de Tiempo , Ablación por Catéter/métodos , Recurrencia
17.
J Cardiothorac Vasc Anesth ; 38(1): 148-154, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37953172

RESUMEN

OBJECTIVES: The authors report their experience of a protocol for deep sedation with ketamine in spontaneous respiration during the pulsed-field ablation (PFA) of atrial fibrillation (AF). DESIGN: Observational, prospective, nonrandomized fashion. SETTING: Single-center hospitalized patients. PARTICIPANTS: All consecutive patients undergoing PFA of AF. INTERVENTIONS: Patients undergoing deep sedation with intravenous ketamine. MEASUREMENTS AND MAIN RESULTS: The authors' sedation protocol involves the intravenous administration of fentanyl (1.5 µg/kg) and midazolam (2 mg) at low doses before local anesthesia with lidocaine. A ketamine adjunct (1 mg/kg) in 5-minute boluses was injected about 5 minutes before the first PFA delivery. The authors enrolled 117 patients (age = 59 ± 10 y, 74.4% males, body mass index = 27.6 ± 5 kg/m2, fluoroscopy time = 24 ± 14 minutes, skin-to-skin time = 80 ± 40 minutes and PFA LA dwell time = 24 ± 7 minutes). By the end of the procedure, pulmonary vein isolation had been achieved in all patients using PFA alone. The mean time under sedation was 54.9 ± 6 minutes, with 92 patients (79%) being sedated for <1 hour. A satisfactory Ramsay Sedation Scale level before ketamine administration was achieved in all patients, except one (80.3% of the patients with rank 3; 18.4% with rank 2). In all procedures, the satisfaction level was found acceptable by both the patient and the primary operator (satisfactory in 98.2% of cases). All patients achieved a Numeric Rating Scale for Pain ≤3 (none or mild). No major procedure or anesthesia-related complications were reported. CONCLUSION: The authors' standardized sedation protocol with the administration of drugs with rapid onset and pharmacologic offset at low doses was safe and effective, with an optimal degree of patient and operator satisfaction.


Asunto(s)
Fibrilación Atrial , Sedación Profunda , Ketamina , Propofol , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Estudios Prospectivos , Administración Intravenosa , Anestesia Local , Fibrilación Atrial/cirugía , Respiración
18.
J Interv Card Electrophysiol ; 67(1): 61-69, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37178189

RESUMEN

BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of patients with symptomatic atrial fibrillation (AF). AF symptoms are highly subjective; however, they are important outcomes for the patient. The aim is to describe the use and impact of a web-based App to collect AF-related symptoms in a population of patients who underwent PVI-C in seven Italian centers. METHODS: A patient App to collect AF-related symptoms and general health status was proposed to all patients who underwent an index PVI-C. Patients were divided into two groups according to the utilization of the App or the non-usage. RESULTS: Out of 865 patients, 353 (41%) subjects composed the App group, and 512 (59%) composed the No-App group. Baseline characteristics were comparable between the two cohorts except for age, sex, type of AF, and body mass index. During a mean follow-up of 7.9±13.8 months, AF recurrence was found in 57/865 (7%) subjects with an annual rate of 7.36% (95% CI:5.67-9.55%) in the No-App versus 10.99% (95% CI:9.67-12.48%) in the App group, p=0.007. In total, 14,458 diaries were sent by the 353 subjects in the App group and 77.1% reported a good health status and no symptoms. In only 518 diaries (3.6%), the patients reported a bad health status, and bad health status was an independent parameter of AF recurrence during follow-up. CONCLUSIONS: The use of a web App to record AF-related symptoms was feasible and effective. Additionally, a bad health status reporting in the App was associated with AF recurrence during follow-up.


Asunto(s)
Fibrilación Atrial , COVID-19 , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Resultado del Tratamiento , Criocirugía/efectos adversos , Venas Pulmonares/cirugía , Recurrencia , Ablación por Catéter/efectos adversos
19.
Artículo en Inglés | MEDLINE | ID: mdl-37985538

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly employed in atrial fibrillation (AF) ablation procedures, with the potential to enhance procedural efficacy. Nevertheless, there is currently a lack of evidence assessing the impact of ICE on the efficiency, effectiveness, and safety outcomes in the context of novel pulsed-field ablation (PFA) for AF. PURPOSE: We aimed to assess whether the use of ICE could improve procedural parameters in a large population undergoing AF ablation with FARAPULSE™ catheter. METHODS: Consecutive patients who had undergone PFA of AF from nine Italian centers were included. In procedures where the ICE catheter was employed for guidance (ICE-guided group), it was used to maneuver the PFA catheter within the left atrium to achieve optimal contact with atrial structures. RESULTS: We analyzed 556 patients: 357 (66%) with paroxysmal AF, 499 (89.7%) de novo PVI. ICE-guided procedures (n = 138) were propensity matched with patients with a standard approach (n = 138), and their outcomes were compared. During ICE-guided procedures, no improvement in procedural metrics was recorded (ICE vs Standard, 23 ± 6 min vs 18.5 ± 9 min for time to PVI, p < 0.0001; 38.8 ± 7 vs 32.5 ± 5 number of PFA deliveries to achieve PVI, p < 0.0001; 68.8 ± 19 min vs 71.8 ± 29 min for primary operator time, p = 0.5301; 16.1 ± 8 min vs 18.2 ± 10 min for fluoroscopy time, p = 0.5476) except for support time (76.8 ± 26 min vs 91.4 ± 37 min, p = 0.0046). No major procedure-related adverse events were reported. CONCLUSION: Our findings confirmed that PFA could be consistently performed in a rapid, safe, and efficacious manner. The use of ICE to guide PFA was not associated with an improvement in procedural metrics.

20.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37846769

RESUMEN

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Criocirugía/métodos , Italia/epidemiología , Sistema de Registros , Ablación por Catéter/métodos , Recurrencia