Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Inn Med (Heidelb) ; 65(8): 787-797, 2024 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-38977442

RESUMEN

Genetic arrhythmia disorders are rare diseases; however, they are a common cause of sudden cardiac death in children, adolescents, and young adults. In principle, a distinction can be made between channelopathies and cardiomyopathies in the context of genetic diseases. This paper focuses on the channelopathies long and short QT syndrome, Brugada syndrome, and catecholaminergic polymorphic ventricular tachycardia (CPVT). Early diagnosis of these diseases is essential, as drug therapy, behavioral measures, and if necessary, implantation of a cardioverter defibrillator can significantly improve the prognosis and quality of life of patients. This paper highlights the pathophysiological and genetic basis of these channelopathies, describes their clinical manifestations, and comments on the principles of diagnosis, risk stratification and therapy.


Asunto(s)
Arritmias Cardíacas , Síndrome de Brugada , Canalopatías , Humanos , Arritmias Cardíacas/genética , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatología , Canalopatías/genética , Canalopatías/diagnóstico , Canalopatías/terapia , Síndrome de Brugada/genética , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/terapia , Taquicardia Ventricular/genética , Taquicardia Ventricular/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Adolescente , Niño , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/terapia , Síndrome de QT Prolongado/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Adulto , Desfibriladores Implantables , Electrocardiografía
2.
PLoS One ; 19(4): e0302321, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38635729

RESUMEN

AIMS: This study investigated whether an activated R-mode in patients carrying a cardiac implantable electronic device (CIED) is associated with worse prognosis during and after an episode of acutely decompensated heart failure (AHF). METHODS: Six hundred and twenty-three patients participating in an ongoing prospective cohort study that phenotypes and follows patients admitted for AHF were studied. We compared CIED carriers with activated R-mode stimulation (CIED-R) to CIED carriers not in R-mode (CIED-0) and patients without CIEDs (no-CIED). The independent impact of R-mode activation on 12-month all-cause death was examined using uni- and multivariable Cox proportional hazards regression taking into account potential confounders, and hazard ratios (HR) with their 95% confidence intervals (CI) were reported. RESULTS: Mean heart rate on admission was lower in CIED-R (n = 37, 16% women) vs. CIED-0 (n = 64, 23% women) or no-CIED (n = 511, 43% women): 70 bpm vs. 80 bpm or 82 bpm; both p<0.001. In-hospital mortality was similar across groups, but age- and sex-adjusted all-cause 12-month mortality risk was differentially affected by R-mode activation; CIED-R vs. CIED-0: HR 2.44, 95%CI 1.25-4.74; CIED-R vs. no-CIED: HR 2.61, 95%CI 1.59-4.29. These effects persisted after multivariable adjustment for potential confounders. Within CIED-R, mortality risk was similar in patients with pacemakers vs. ICDs and in subgroups with left ventricular ejection fraction (LVEF) <50% vs. ≥50%. CONCLUSION: In patients admitted with AHF, R-mode stimulation was associated with a significantly increased 12-month mortality risk. Our findings shed new light on "admission heart rate" as a potentially treatable target in AHF. Our data are compatible with the concept that chronotropic incompetence contributes to an adverse outcome in these patients and may not be adequately treated through accelerometer-based R-mode stimulation.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Femenino , Masculino , Volumen Sistólico , Estudios Prospectivos , Función Ventricular Izquierda , Estudios Retrospectivos
3.
PLoS One ; 17(8): e0269816, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35960722

RESUMEN

OBJECTIVES: The study aims to investigate the impact of COVID-19 pandemic on physical activity and frequency of implantable cardioverter-defibrillator (ICD) therapies of patients with cardiac implantable electronic devices. METHODS AND RESULTS: Physical activity, heart rate and ICD-therapies were assessed via routine remote monitoring over two years. We focussed on a 338-day period during COVID-19 pandemic that was divided in 6 time-intervals defined by public health interventions and compared to the previous regular year. Paired nonparametric longitudinal analysis was performed to detect differences between time-intervals. To model effects of age, sex and time we applied a nonparametric ANOVA-type-statistic. 147 patients with cardiac implantable electronic devices were analysed. Longitudinal analysis of physical activity in 2019 and 2020 showed a specific weekly and seasonal pattern. Physical activity was reduced during the pandemic (mean daily physical activity 2019: 12.4% vs. 2020: 11.5%; p<0.0001) with the strongest reductions (fold changes 0.885/0.889, p<0.0001/p<0.0001) during the two lockdown-periods. In older patients (>70 years), physical activity was decreased in every time-interval of the year 2020. In time-intervals of eased restrictions, physical activity of younger patients (≤70 years) was not different compared to 2019. No variation in mean heart rate, arrhythmia-burden and count of ICD-therapies was found. CONCLUSION: Physical activity shows fluctuations dependent on days of the week and time of the year. During the pandemic, physical activity was reduced in patients with cardiac implantable electronic devices with the strongest reductions during lockdown-periods. Younger patients resumed former levels of physical activity in times of eased restrictions while older patients remained less active. Thus, activation of the elderly population is important to prevent long-term health impairments due to the pandemic.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Anciano , COVID-19/epidemiología , Control de Enfermedades Transmisibles , Electrónica , Ejercicio Físico , Humanos , Pandemias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA