1.
ACS Appl Mater Interfaces ; 13(22): 26330-26338, 2021 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-34037381

RESUMEN

The hole density of individual copper sulfide nanocrystals (Cu2-xS NCs) is determined from the stoichiometric mismatch (x) between copper and sulfide atoms. Consequently, the electronic properties of the material vary over a range of x. To exploit Cu2-xS NCs in devices, assemblies of NCs are typically required. Herein, we investigate the influence of x, referred to as the stoichiometric doping effect, on the structural, optical, electrical, and thermoelectric properties of electronically coupled Cu2-xS NC assemblies. The doping process is done by immersing the solid NC assemblies into a solution containing a Cu(I) complex for different durations (0-10 min). As Cu+ gradually occupied the copper-deficient sites of Cu2-xS NCs, x could be controlled from 0.9 to less than 0.1. Consequently, the near-infrared (NIR) absorbance of Cu2-xS NC assemblies changes systematically with x. With increasing x, electrical conductivity increased and the Seebeck coefficient decreased systematically, leading to the maximal thermoelectric power factor from a film of Cu2-xS NCs at an optimal doping condition yielding x = 0.1. The physical characteristics of the Cu2-xS NC assemblies investigated herein will provide guidelines for exploiting this emerging class of nanocrystal system based on doping.

2.
Materials (Basel) ; 12(20)2019 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-31614936

RESUMEN

Biomineralization of calcium carbonate has interesting characteristics of intricate morphology formation with controlled crystal polymorphs. In particular, modification of calcite morphology with diverse additives has been the focus of many biomimetic and bioinspired studies. The possible role of strontium ions in enhancing the morphology-modifying ability of macromolecules was investigated. In the present study, concentrations of strontium ions were comparable to that in seawater, and anionic poly(acrylic acid) and cationic poly(ethylene imine) were used as model macromolecules. When strontium ions were combined with anionic poly(acrylic acid), new types of calcite surfaces, most likely {hk0}, appeared to drastically change the morphology of the crystals, which was not observed with cationic poly(ethylene imine). This behavior of strontium ions was quite similar to that of magnesium ions, which is intriguing because both ions are available from seawater to be utilized during biomineralization.

3.
ACS Appl Mater Interfaces ; 11(40): 37043-37050, 2019 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-31518103

RESUMEN

As practical interest in stretchable electronics increases for future applications in wearables, healthcare, and robotics, the demand for electrical interconnects with high electrical conductivity, durability, printability, and adhesion is growing. Despite the high electrical conductivity and stretchability of most previous interconnects, they lack stable conductivity against strain and adhesion to stretchable substrates, leading to a limitation for their practical applications. Herein, we propose a stretchable conductive adhesive consisting of silver particles with carbon nanotube as an auxiliary filler in silicone adhesives. The conductive adhesive exhibits a high initial conductivity of 6450 S cm-1. They show little change in conductivity over 3000 stretching cycles at 50% strain, currently the highest stability reported for elastic conductors. Based on strong adhesion to stretchable substrates, the gel-free, dry adhesives printed on an elastic bandage for electrocardiography monitoring exhibit an extremely stable performance upon movement of the subject, even after several cycles of detachment-reattachment and machine washing.


Asunto(s)
Adhesivos/química , Conductividad Eléctrica , Electrónica , Impresión , Textiles , Electrodos , Siliconas/química
4.
Nanoscale ; 7(17): 7540-4, 2015 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-25850005

RESUMEN

Solution-gated graphene transistors were developed recently for use in pH sensor applications. The device operation is understood to rely on the capability of hydronium and hydroxide ions in solution to change the electrical properties of graphene. However, hydronium and hydroxide ions are accompanied by other ionic species in a typical acidic or basic solution and, therefore, the roles of these other ionic species must be also considered to fully understand the pH response of such devices. Using series of pH buffer solutions designed carefully, we verified that the magnitude and even the direction of pH-dependent Dirac voltage (VDirac) shift (the typical pH sensing indicator) depend strongly on the concentration and composition of the buffers used. The results indicate that the interpretation of the apparent pH-dependent VDirac response of a solution-gated graphene transistor must include the contributions of the additional ions in the solution.

5.
Clin Orthop Relat Res ; 468(5): 1296-304, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-19949906

RESUMEN

BACKGROUND: The greater lubricity and resistance to scratching of oxidized zirconium femoral components are expected to result in less polyethylene wear than cobalt-chrome femoral components. QUESTIONS/PURPOSES: We examined polyethylene wear particles in synovial fluid and compared the weight, size (equivalent circle diameter), and shape (aspect ratio) of polyethylene wear particles in knees with an oxidized zirconium femoral component with those in knees with a cobalt-chrome femoral component. PATIENTS AND METHODS: One hundred patients received an oxidized zirconium femoral component in one knee and a cobalt-chrome femoral component in the other. There were 73 women and 27 men with a mean age of 55.6 years (range, 44-60 years). The minimum followup was 5 years (mean, 5.5 years; range, 5-6 years). Polyethylene wear particles were analyzed using thermogravimetric methods and scanning electron microscopy. RESULTS: The weight of polyethylene wear particles produced at the bearing surface was 0.0223 +/- 0.0054 g in 1 g synovial fluid in patients with an oxidized zirconium femoral component and 0.0228 +/- 0.0062 g in patients with a cobalt-chrome femoral component. Size and shape of polyethylene wear particles were 0.59 +/- 0.05 microm and 1.21 +/- 0.24, respectively, in the patients with an oxidized zirconium femoral component and 0.52 +/- 0.03 microm and 1.27 +/- 0.31, respectively, in the patients with a cobalt-chrome femoral component. Knee Society knee and function scores, radiographic results, and complication rate were similar between the knees with an oxidized zirconium and cobalt-chrome femoral component. CONCLUSIONS: The weight, size, and shape of polyethylene wear particles were similar in the knees with an oxidized zirconium and a cobalt-chrome femoral component. We found the theoretical advantages of this surface did not provide the actual advantage. LEVEL OF EVIDENCE: Level I, therapeutic study. See the guidelines for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Aleaciones de Cromo/análisis , Cuerpos Extraños , Prótesis de la Rodilla , Polietileno/análisis , Líquido Sinovial/química , Circonio/análisis , Adulto , Análisis de Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Termogravimetría , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA