Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 225: 115084, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36693286

RESUMEN

The microRNA21 (miR-21), a specific tumor biomarker, is crucial for the diagnosis of several cancer types, and investigation of its overexpression pattern is important for cancer diagnosis. Herein, we report a low-cost, rapid, ultrasensitive, and convenient biosensing strategy for the detection of miR-21 using a nanoplasmonic array chip coupled with gold nanoparticles (AuNPs). This sensing platform combines the surface plasmon resonance effect of nanoplasmonics (NanoSPR) and the localized surface plasmon resonance (LSPR) effect, which allows the real-time monitoring of the subtle optical density (OD) changes caused by the variations in the dielectric constant in the process of the hybridization of the target miRNA. Using this method, the miRNA achieves a broad detection range from 100 aM to 1 µM, and with a limit of detection (LoD) of 1.85 aM. Furthermore, this assay also has a single-base resolution to discriminate the highly homologous miRNAs. More importantly, this platform has high throughput characteristics (96 samples can be detected simultaneously). This strategy exhibits more than 86.5 times enhancement in terms of sensitivity compared to that of traditional biosensors.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , MicroARNs , Neoplasias , Humanos , Técnicas Biosensibles/métodos , Oro , Biomarcadores de Tumor/genética , Resonancia por Plasmón de Superficie/métodos , MicroARNs/genética , Neoplasias/diagnóstico , Neoplasias/genética , Límite de Detección
2.
Chem Eng J ; 451: 138822, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36060034

RESUMEN

The novel mutations attributed by the high mutagenicity of the SARS-CoV-2 makes its prevention and treatment challenging. Developing an ultra-fast, point-of-care-test (POCT) protocol is critical for responding to large-scale spread of SARS-CoV-2 in public places and in resource-poor remote areas. Here, we developed a nanoplasmonic enhanced isothermal amplification (NanoPEIA) strategy that combines a nanoplasmonic sensor with isothermal amplification. The novel strategy provides an ideal easy-to operate detection platform for obtaining accurate, ultra-fast and high-throughput (96 samples can be tested together) data. For clinical samples with viral detection at Ct value <25, the entire process (including sample preparation, virus lysis, detection, and data analysis) can be completed within six minutes. The method is also appropriate for detection of SARS-CoV-2 γ-coronavirus mutants. The NanoPEIA method was validated using clinical samples from 21 patients with SARS-CoV-2 infection and 31 healthy individuals. The detection result on the 52 clinical samples for SARS-CoV-2 showed that the NanoPEIA platform had a 100% sensitivity for N and orf1ab genes, which was higher than those obtained using RT-qPCR (88.9% and 90.0%, respectively). The specificities of 31 clinical negative samples were 92.3% and 91.7% for the N gene and the orf1ab gene, respectively. The limits of detection (LoD) of the clinical samples were 28.3 copies/mL and 23.3 copies/mL for the N gene and the orf1ab gene, respectively. The efficient NanoPEIA detection strategy facilitates real-time detection and visualization within ultrashort durations and can be applied for POCT diagnosis in resource-poor and highly populated areas.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA