Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Pediatr Radiol ; 47(10): 1312-1320, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28631157

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. OBJECTIVE: To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. MATERIALS AND METHODS: We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. RESULTS: Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. CONCLUSION: Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.


Asunto(s)
Apendicitis/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas
2.
Pediatr Radiol ; 45(2): 181-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24996812

RESUMEN

BACKGROUND: Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. OBJECTIVE: This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDIvol). MATERIALS AND METHODS: Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDIvol. Reduced CTDIvol was achieved primarily by reductions in effective tube current-time product (mAseff) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDIvol, size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. RESULTS: Between groups A and B, mean CTDIvol was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. CONCLUSION: Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDIvol and SSDE by nearly half as compared to the hospital's traditional weight-based protocols.


Asunto(s)
Apendicitis/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Niño , Medios de Contraste , Femenino , Humanos , Masculino , Fantasmas de Imagen , Dosis de Radiación , Radiografía Abdominal , Estudios Retrospectivos , Sensibilidad y Especificidad
3.
Childs Nerv Syst ; 29(12): 2275-80, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23728433

RESUMEN

OBJECTIVE: To determine the feasibility and test characteristics of optic nerve sheath diameter (ONSD) measured by ocular ultrasound as a screening tool for ventriculoperitoneal shunt (VPS) failure. METHODS: Prospective observational study using a convenience sample of children 6 months to 18 years of age, presenting to an academic pediatric emergency department for evaluation of possible VPS failure between September 2008 and March 2009. ONSD was measured by anterior transbulbar and lateral transbulbar techniques. Mean ONSD was compared between subjects with and without shunt failure, as determined by neurosurgical decision to operate. RESULTS: A total of 39 encounters were completed, including 20 VPS failures. The mean ONSD was 4.5 ± 0.9 and 5.0 ± 0.6 mm among encounters with and without shunt failure (p = 0.03), respectively. The mean ONSD was not statistically different when obtained by the anterior transbulbar vs. the lateral transbulbar approach (4.8 ± 1.0 vs. 4.7 ± 0.8 mm, p = 0.12). ONSD ultrasound had a sensitivity of 61.1 % (95 % CI 35.7-82.7) and specificity of 22.2 % (95 % CI 6.4-47.6 %) for detecting shunt failure in this sample. CONCLUSIONS: ONSD ultrasound does not appear to be a useful primary screening tool in emergency department evaluation of VPS failure. There was no difference between the anterior transbulbar approach and the lateral transbulbar approach. Children with VPS in our sample have larger ONSD measurements than in previously reported studies.


Asunto(s)
Falla de Equipo , Nervio Óptico/diagnóstico por imagen , Sistemas de Atención de Punto , Derivación Ventriculoperitoneal/efectos adversos , Adolescente , Niño , Preescolar , Servicio de Urgencia en Hospital , Femenino , Humanos , Lactante , Hipertensión Intracraneal/diagnóstico por imagen , Hipertensión Intracraneal/etiología , Masculino , Estudios Prospectivos , Ultrasonografía
4.
Pediatr Radiol ; 43(9): 1128-35, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23558461

RESUMEN

BACKGROUND: During the last decade, there has been a movement in the United States toward utilizing size-appropriate radiation doses for pediatric body CT, with smaller doses given to smaller patients. OBJECTIVE: This study assesses community adoption of size-appropriate pediatric CT techniques. Size-specific dose estimates (SSDE) in pediatric body scans are compared between community facilities and a university children's hospital that tailors CT protocols to patient size as advocated by Image Gently. MATERIALS AND METHODS: We compared 164 pediatric body scans done at community facilities (group X) with 466 children's hospital scans. Children's hospital scans were divided into two groups: A, 250 performed with established pediatric weight-based protocols and filtered back projection; B, 216 performed with addition of iterative reconstruction technique and a 60% reduction in volume CT dose index (CTDIvol). SSDE was calculated and differences among groups were compared by regression analysis. RESULTS: Mean SSDE was 1.6 and 3.9 times higher in group X than in groups A and B and 2.5 times higher for group A than group B. A model adjusting for confounders confirmed significant differences between group pairs. CONCLUSIONS: Regional community hospitals and imaging centers have not universally adopted child-sized pediatric CT practices. More education and accountability may be necessary to achieve widespread implementation. Since even lower radiation doses are possible with iterative reconstruction technique than with filtered back projection alone, further exploration of the former is encouraged.


Asunto(s)
Adhesión a Directriz/estadística & datos numéricos , Protección Radiológica/estadística & datos numéricos , Protección Radiológica/normas , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Tomografía Computarizada por Rayos X/normas , Imagen de Cuerpo Entero/estadística & datos numéricos , Imagen de Cuerpo Entero/normas , Niño , Femenino , Hospitales Pediátricos/estadística & datos numéricos , Humanos , Masculino , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Programas Médicos Regionales/estadística & datos numéricos , Estados Unidos , Revisión de Utilización de Recursos
5.
Clin Pract ; 2(2): e37, 2012 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-24765436

RESUMEN

We report on a 5-year-old boy with seeding of the peritoneum and a ventriculoperitoneal shunt tract by anaplastic medulloblastoma. The role of ventriculoperitoneal shunting in the spread of primary central nervous system tumors has been controversial. In the case reported here, the unique distribution of tumor implants on ultrasound and multiplanar computed tomography gives further credence to the argument that ventriculoperitoneal shunting is a pathway for extraneural metastases of primary central nervous system tumors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA