Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 20(8): 1499-508, 2005 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-15626603

RESUMEN

A novel analytical system AWACSS (automated water analyser computer-supported system) based on immunochemical technology has been developed that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration nor pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) (98/83/EC, 1998) and Water Framework Directive WFD (2000/60/EC, 2000), drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The instrument was equipped with remote control and surveillance facilities. The system's software allows for the internet-based networking between the measurement and control stations, global management, trend analysis, and early-warning applications. The experience of water laboratories has been utilised at the design of the instrument's hardware and software in order to make the system rugged and user-friendly. Several market surveys were conducted during the project to assess the applicability of the final system. A web-based AWACSS database was created for automated evaluation and storage of the obtained data in a format compatible with major databases of environmental organic pollutants in Europe. This first part article gives the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part article reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods.


Asunto(s)
Técnicas Biosensibles/instrumentación , Monitoreo del Ambiente/instrumentación , Inmunoensayo/instrumentación , Internet , Compuestos Orgánicos/análisis , Programas Informáticos , Contaminantes Químicos del Agua/análisis , Algoritmos , Técnicas Biosensibles/métodos , Biotecnología/instrumentación , Biotecnología/métodos , Sistemas de Administración de Bases de Datos/instrumentación , Monitoreo del Ambiente/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Inmunoensayo/métodos , Almacenamiento y Recuperación de la Información/métodos , Microquímica/instrumentación , Microquímica/métodos , Microcomputadores , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Diseño de Software , Interfaz Usuario-Computador
2.
Biosens Bioelectron ; 20(8): 1509-19, 2005 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-15626604

RESUMEN

A novel analytical system AWACSS (Automated Water Analyser Computer Supported System) based on immunochemical technology has been evaluated that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration or pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) [98/83/EC, 1998. Council Directive (98/83/EC) of 3 November 1998 relating to the quality of water intended for human consumption. Off. J. Eur. Commun. L330, 32-54] and Water Framework Directive (WFD) [2000/60/EC, 2000. Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 establishing a framework for Community action in the field of water policy. Off. J. Eur. Commun. L327, 1-72], drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The first part article gave the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods. The systems' capability for analysing a wide range of environmental organic micro-pollutants, such as modern pesticides, endocrine disrupting compounds and pharmaceuticals in surface, ground, drinking and waste water is shown. In addition, a protocol using reconstitution of extracts of solid samples, developed and applied for analysis of river sediments and food samples, is presented. Finally, the overall performance of the AWACSS system in comparison to the conventional analytical techniques, which included liquid and gas chromatographic systems with diode-array UV and mass spectrometric detectors, was successfully tested in an inter-laboratory collaborative trial among six project partners.


Asunto(s)
Monitoreo del Ambiente/instrumentación , Análisis de Falla de Equipo , Inmunoensayo/instrumentación , Internet , Compuestos Orgánicos/análisis , Programas Informáticos , Contaminantes Químicos del Agua/análisis , Algoritmos , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Biotecnología/instrumentación , Biotecnología/métodos , Sistemas de Administración de Bases de Datos/instrumentación , Monitoreo del Ambiente/métodos , Diseño de Equipo , Inmunoensayo/métodos , Almacenamiento y Recuperación de la Información/métodos , Microquímica/instrumentación , Microquímica/métodos , Microcomputadores , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Diseño de Software , Interfaz Usuario-Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA