Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Chemistry ; 28(3): e202103511, 2022 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-34792822

RESUMEN

This report describes the synthesis of a [2.2]paracyclophane-derived annulated 3-amino-imidazole ligand library through a Groebke-Blackburn-Bienaymé three-component reaction (GBB-3CR) approach employing formyl-cyclophanes in combination with diverse aliphatic and aromatic isocyanides and heteroaromatic amidines. The GBB-3CR process gives access to skeletally-diverse cyclophanyl imidazole ligands, namely 3-amino-imidazo[1,2-a]pyridines and imidazo[1,2-a]pyrazines. Additionally, a one-pot protocol for the GBB-3CR by an in situ generation of cyclophanyl isocyanide is demonstrated. The products were analyzed by detailed spectroscopic techniques, and the cyclophanyl imidazo[1,2-a]pyridine was confirmed unambiguously by single-crystal X-Ray crystallography. The cyclophanyl imidazole ligands can be readily transformed to showcase their useful utility in preparing N,C-palladacycles through regioselective ortho-palladation.


Asunto(s)
Cianuros , Imidazoles , Ciclización , Ligandos
2.
Appl Spectrosc ; 64(3): 262-7, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20223059

RESUMEN

Cardiovascular disease is the leading cause of death in Western civilization. In this pilot study we evaluated a new method for the diagnosis of myocardial infarction and heart failure by determining the typical fingerprint in the infrared (IR) spectrum of 1 microL of a dried patient serum sample by Fourier transform IR spectroscopy. For classification, cluster analysis and artificial neural networks (ANN) were applied. In this study 567 subjects were enrolled, comprising 225 controls (Co) and 342 patients with myocardial infarction (MI) (n = 157) and heart failure (HF) (n = 185). By applying artificial neural network algorithms, the following sensitivities and specificities of the same spectra were determined: MI versus Co (98%, 97%), HF versus Co (98%, 100%), MI versus HF (100%, 100%), and MI plus HF versus Co (100%, 100%). Based on our data, mid-IR spectroscopy appears to be a promising new method to diagnose heart diseases from serum samples. Artificial neural network algorithms proved to be superior to cluster analysis for correct prediction.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Infarto del Miocardio/diagnóstico , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Algoritmos , Análisis por Conglomerados , Insuficiencia Cardíaca/sangre , Humanos , Infarto del Miocardio/sangre , Redes Neurales de la Computación , Proyectos Piloto , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA