Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 90(4): 043502, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31042980

RESUMEN

This paper reports about a novel approach to the absolute intensity calibration of an electron cyclotron emission (ECE) spectroscopy system. Typically, an ECE radiometer consists of tens of separated frequency channels corresponding to different plasma locations. An absolute calibration of the overall diagnostic including near plasma optics and transmission line is achieved with blackbody sources at LN2 temperature and room temperature via a hot/cold calibration mirror unit. As the thermal emission of the calibration source is typically a few thousand times lower than the receiver noise temperature, coherent averaging over several hours is required to get a sufficient signal to noise ratio. A forward model suitable for any radiometer calibration using the hot/cold method and a periodic switch between them has been developed and used to extract the voltage difference between the hot and cold temperature source via Bayesian analysis. In contrast to the classical analysis which evaluates only the reference temperatures, the forward model takes into account intermediate effective temperatures caused by the finite beam width and thus uses all available data optimally. This allows the evaluation of weak channels where a classical analysis would not be feasible, is statistically rigorous, and provides a measurement of the beam width. By using a variance scaling factor, a model sensitive adaptation of the absolute uncertainties can be implemented, which will be used for the combined diagnostic Bayesian modeling analysis.

2.
Phys Plasmas ; 24(5): 055503, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-29104420

RESUMEN

The first physics operation phase on the stellarator experiment Wendelstein 7-X was successfully completed in March 2016 after about 10 weeks of operation. Experiments in this phase were conducted with five graphite limiters as the primary plasma-facing components. Overall, the results were beyond the expectations published shortly before the start of operation [Sunn Pedersen et al., Nucl. Fusion 55, 126001 (2015)] both with respect to parameters reached and with respect to physics themes addressed. We report here on some of the most important plasma experiments that were conducted. The importance of electric fields on global confinement will be discussed, and the obtained results will be compared and contrasted with results from other devices, quantified in terms of the fusion triple product. Expected values for the triple product in future operation phases will also be described and put into a broader fusion perspective.

3.
Proc Math Phys Eng Sci ; 472(2191): 20160201, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27493569

RESUMEN

Defects produced during selective laser sintering (SLS) are difficult to non-destructively detect after build completion without the use of X-ray-based methods. Overcoming this issue by assessing integrity on a layer-by-layer basis has become an area of significant interest for users of SLS apparatus. Optical coherence tomography (OCT) is used in this study to detect surface texture and sub-surface powder, which is un-melted/insufficiently sintered, is known to be a common cause of poor part integrity and would prevent the use of SLS where applications dictate assurance of defect-free parts. To demonstrate the capability of the instrument and associated data-processing algorithms, samples were built with graduated porosities which were embedded in fully dense regions in order to simulate defective regions. Simulated in situ measurements were then correlated with the process parameters used to generate variable density regions. Using this method, it is possible to detect loose powder and differentiate between densities of ±5% at a sub-surface depth of approximately 300 µm. In order to demonstrate the value of OCT as a surface-profiling technique, surface texture datasets are compared with focus variation microscopy. Comparable results are achieved after a spatial bandwidth- matching procedure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA