Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39288784

RESUMEN

At the Heidelberg Ion-Beam Therapy Center, the track structure of carbon ions of therapeutic energy after penetrating layers of simulated tissue was investigated for the first time. Measurements were conducted with carbon ion beams of different energies and polymethyl methacrylate (PMMA) absorbers of different thicknesses to realize different depths in the phantom along the pristine Bragg peak. Ionization cluster size (ICS) distributions resulting from the mixed radiation field behind the PMMA absorbers were measured using an ion-counting nanodosimeter. Two different measurements were carried out: (i) variation of the PMMA absorber thickness with constant carbon ion beam energy and (ii) combined variation of PMMA absorber thickness and carbon ion beam energy such that the kinetic energy of the carbon ions in the target volume is constant. The data analysis revealed unexpectedly high mean ICS values compared to stopping power calculations and the data measured at lower energies in earlier work. This suggests that in the measurements the carbon ion kinetic energies behind the PMMA absorber may have deviated considerably from the expected values obtained by the calculations. In addition, the results indicate the presence of a marked contribution of nuclear fragments to the measured ICS distributions, especially if the carbon ion does not cross the target volume.

2.
Phys Med Biol ; 66(11)2021 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-33902019

RESUMEN

This work presents a comprehensive catalog of x-ray spectra measured from x-ray tubes with tungsten, molybdenum, and rhodium anodes generated at tube potentials between 10 and 50 kV in steps of 1 kV. They can serve as an input for dose calculations, image quality calculations, investigations of detector features, and validations of computational spectral models, among other things. The measurements are performed by means of a high-purity germanium detector-based spectrometer 1 m from the x-ray sources without any added filtration. The x-ray tubes are characterized by thin beryllium exit windows (0.15-4 mm); thus, for energies above 15 keV, the spectra recorded can be considered approximately unfiltered. This allows potential users of the catalog to computationally add any filter to the spectra in order to create special radiation qualities of their choice. To validate this option, a small number of spectra are recorded with filter materials in place whose purity and thickness are known with high precision. These spectra are compared to the corresponding spectra from the catalog obtained by means of computationally added filters. The two types of spectra agree extremely well. Several typical mammographic radiation qualities are selected to compare the spectra obtained from the catalog presented here with corresponding spectra obtained from other catalogs published by Booneet al(1997Med. Phys.241863-74) and Hernandezet al(2017Med. Phys.442148-60). In contrast to the work presented here, those spectra rely partly or fully on calculations. A quantitative comparison is made by means of typical x-ray quality descriptors such as the mean energy and the first and second half-value layer. The results obtained from the Boone catalog match those of the current catalog sufficiently well for the Mo- and Rh-anode-based spectra. However, significant differences up to 10 times the estimated uncertainties are found for the quality descriptors evaluated from the spectra of Hernandezet aland the W-anode based spectra of Booneet al.


Asunto(s)
Rodio , Electrodos , Mamografía , Tungsteno , Rayos X
3.
J Phys Chem A ; 124(44): 9261-9271, 2020 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-33079556

RESUMEN

In this work, we report a systematic search of metastable C6Hn2+ (n = 1-6) dications from electron impact time-of-flight measurements of several benzene derivatives in combination with global minimum search based on the genetic algorithm. Our theoretical calculations reveal that the C6Hn2+ (n < 6) global minimum structures are completely different from that of the benzene dication, featuring linear carbon chains and/or cyclopropenylium moieties. Experimentally, the doubly charged species were investigated for a wide range of electron impact energies, from 20 to 2000 eV, for benzene and several monosubstituted compounds containing either electron-withdrawing or -donating groups. Furthermore, the C6Hn2+ production, evaluated from the yields of the dications with respect to that of the parent ion (or parent dication), was compared to those obtained from charge exchange in the doubly charged 2E spectra and electron impact experiments available in the literature. The yields of the long-lived benzene dications were contrasted to those analogues formed in chlorobenzene. Moreover, the formation of C6Hn2+ species is strongly dependent on the nature of substituent groups, with electron-withdrawing ones favoring the dication formation.

4.
Phys Chem Chem Phys ; 21(45): 24984-24992, 2019 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-31709438

RESUMEN

Ring strain energy is a very well documented feature of neutral cycloalkanes, and influences their structural, thermochemical and reactivity properties. In this work, we apply density functional theory and high-level coupled cluster calculations to describe the geometry and relative stability of C6H12+˙ radical cations, whose cyclic isomers are prototypes of singly-charged cycloalkanes. Molecular ions with the mentioned stoichiometry were produced via electron impact experiments using a gaseous cyclohexane sample (20-2000 eV). From our calculations, in addition to structures that resemble linear and branched alkenes as well as distinct conformers of cyclohexane, we have found low-lying species containing three-, four- and five-membered rings with the presence of an elongated C-C bond. Remarkably, the stability trend of these ring-bearing radical cations is anomalous, and the three-membered species are up to 11.3 kcal mol-1 more stable than the six-membered chair structure. Generalized Valence Bond calculations and the Spin Coupled theory with N electrons and M orbitals were used in conjunction with the Generalized Product Function Energy Partitioning (GPF-EP) method and Interference Energy Analysis (IEA) to describe the chemical bonding in such moieties. Our results confirm that these elongated C-C motifs are one-electron sigma bonds. Our calculations also reveal the effects that drive thermochemical preference of strained systems over their strained-free isomers, and the origin of the unusual stability trend observed for cycloalkane radical cations.

5.
Radiat Prot Dosimetry ; 183(1-2): 182-186, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30535057

RESUMEN

In nanodosimetry, the ionization component of charged particle track structure is characterized by measuring the frequency distribution of ionizations in target volumes that simulate nanometric sites in liquid water. For the Ion Counter nanodosimeter at PTB, the sensitive volume is defined by the electrical field and the extraction aperture. In this paper, a procedure is presented to define a cylindrical effective measurement target based on the second moments of the detection efficiency map. An analytical model of the efficiency map is developed to investigate the dependence of the simulated site size on the nanodosimeter's operating parameters. Within the limits of the simplifying assumptions, the model gives a reasonable approximation of the efficiency map.


Asunto(s)
Iones/análisis , Nanotecnología/instrumentación , Radiometría/instrumentación , Diseño de Equipo , Modelos Teóricos
6.
Radiat Prot Dosimetry ; 183(1-2): 131-135, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30561691

RESUMEN

In recent years, several approaches have been proposed to provide an understanding of the enhanced relative biological effectiveness of ion beams based on multi-scale models of their radiation effects. Among these, the BioQuaRT project was the only one which focused on developing metrology for a multi-scale characterization of particle track structure. The progress made within the BioQuaRT project has motivated the formation of a department 'Radiation Effects' at PTB dedicated to metrological research on ionizing radiation effects. This paper gives an overview of the department's present research directions and shortly discusses ideas for the future development of metrology related to biological effects of ion beams that are based on a stakeholder consultation.


Asunto(s)
Fenómenos Fisiológicos Celulares/efectos de la radiación , Daño del ADN/efectos de la radiación , Aceleradores de Partículas/instrumentación , Radiobiología/instrumentación , Relación Dosis-Respuesta en la Radiación , Alemania , Transferencia Lineal de Energía , Radiación Ionizante , Efectividad Biológica Relativa
7.
J Chem Phys ; 145(10): 104301, 2016 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-27634254

RESUMEN

For track structure simulations in the Bragg peak region, measured electron emission cross sections of DNA constituents are required as input for developing parameterized model functions representing the scattering probabilities. In the present work, double differential cross sections were measured for the electron emission from vapor-phase pyrimidine, tetrahydrofuran, and trimethyl phosphate that are structural analogues to the base, the sugar, and the phosphate residue of the DNA, respectively. The range of proton energies was from 75 keV to 135 keV, the angles ranged from 15° to 135°, and the electron energies were measured from 10 eV to 200 eV. Single differential and total electron emission cross sections are derived by integration over angle and electron energy and compared to the semi-empirical Hansen-Kocbach-Stolterfoht (HKS) model and a quantum mechanical calculation employing the first Born approximation with corrected boundary conditions (CB1). The CB1 provides the best prediction of double and single differential cross section, while total cross sections can be fitted with semi-empirical models. The cross sections of the three samples are proportional to their total number of valence electrons.


Asunto(s)
ADN/química , Electrones , Protones , Furanos/química , Modelos Moleculares , Conformación Molecular , Organofosfatos/química , Pirimidinas/química , Volatilización
8.
Phys Med Biol ; 61(10): 3698-711, 2016 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-27081911

RESUMEN

The Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT) was extended to study the patterns of energy deposition at sub-micrometer distance from individual ion tracks. Dose distributions for low-energy (1)H, (4)He, (12)C and (16)O ions measured in several experiments are well described by the model in a broad range of radial distances, from 0.5 to 3000 nm. Despite the fact that such distributions are characterized by long tails, a dominant fraction of deposited energy (∼80%) is confined within a radius of about 10 nm. The probability distributions of clustered ionization events in nanoscale volumes of water traversed by (1)H, (2)H, (4)He, (6)Li, (7)Li, and (12)C ions are also calculated. A good agreement of calculated ionization cluster-size distributions with the corresponding experimental data suggests that the extended MCHIT can be used to characterize stochastic processes of energy deposition to sensitive cellular structures.


Asunto(s)
Radioterapia de Iones Pesados , Radioterapia de Iones Pesados/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Simulación por Computador , Radioterapia de Iones Pesados/normas , Programas Informáticos
9.
Artículo en Inglés | MEDLINE | ID: mdl-24229305

RESUMEN

Track structure Monte Carlo simulations are frequently applied in micro- and nanodosimetry to calculate the radiation transport in detail. The use of a well-validated set of cross section data in such simulation codes ensures accurate calculations of transport parameters, such as ionization yields. These cross section data are, however, scarce and often discrepant when measured by different groups. This work surveys literature data on ionization and charge-transfer cross sections of nitrogen, methane, and propane for electrons, protons, and helium particles, focusing on the energy range between 100 keV and 20 MeV. Based on the evaluated data, different models for the parametrization of the cross section data are implemented in the code ptra, developed for simulating proton and alpha particle transport in an ion-counting nanodosimeter. The suitability of the cross section data is investigated by comparing the calculated mean ionization cluster size and energy loss with experimental results in either nitrogen or propane. For protons, generally good agreement between measured and simulated data is found when the Rudd model is used in ptra. For alpha particles, however, a considerable influence of different parametrizations of cross sections for ionization and charge transfer is observed. The ptra code using the charge-transfer data is, nevertheless, successfully benchmarked by the experimental data for the calculation of nanodosimetric quantities, but remaining discrepancies still have to be further investigated (up to 13% lower energy loss and 19% lower mean ionization cluster size than in the experiment). A continuation of this work should investigate data for the energy loss per interaction as well as differential cross section data of nitrogen and propane. Interpolation models for ionization and charge-transfer data are proposed. The Barkas model, frequently used for a determination of the effective charge in the ionization cross section, significantly underestimates both the energy loss (by up to 19%) and the mean ionization cluster size (up to 65%) for alpha particles. It is, therefore, not recommended for particle-track simulations.

10.
Med Phys ; 31(12): 3485-91, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15651631

RESUMEN

The edge method for measuring the modulation transfer function (MTF) has recently gained popularity due to its simplicity and appropriateness particularly for digital imaging systems. Often edge test devices made of rather thin metal sheets are used, which are semitransparent to x rays and may generate scattered radiation. The effect of this scattered radiation on the determined MTF was investigated both theoretically (assuming an ideal detector) and experimentally using a CsI-based digital detector. It was found that the MTF increases due to the scattered radiation for all spatial frequencies larger than 0 mm(-1). The theoretical model developed in this study predicts that the maximum error compared to the true detector MTF is given by S/A, where A is the attenuated fraction and S is the scattered fraction reaching the detector, relative to the incident radiation. Theoretical and experimental results are in good agreement for radiation qualities corresponding to general radiography (RQA3, RQA5, and RQA7), whereas for chest beam quality (RQA9) the experimentally observed MTF error is larger than predicted by the simple model, possibly because the energy response of the CsI-based detector differs from that of an ideal one. The theoretical MTF error reaches a value of 18% for a 0.25 mm thick lead edge of RQA9. Since the MTF enters squared into the determination of the detective quantum efficiency (DQE), an error of at least 36% in DQE may result when using this edge test device. In conclusion, the use of fully absorbing edge material is advised for MTF determination with the edge method.


Asunto(s)
Algoritmos , Análisis de Falla de Equipo/métodos , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Análisis de Falla de Equipo/instrumentación , Análisis Numérico Asistido por Computador , Intensificación de Imagen Radiográfica/instrumentación , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA