Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Arq Bras Cardiol ; 121(9): e20240310, 2024 Sep.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-39352189

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most prevalent cardiac arrhythmia, and its presentation differs according to age and sex. Recent studies have revealed differences in AF among various demographic groups, including the Latin American population. OBJECTIVES: To better understand potential disparities in AF prevalence and treatment strategies in the Brazilian population through data from a large multicentric prospective registry. METHODS: The Rede D'Or AF registry is a multicenter prospective observational study including patients aged ≥ 18 years with AF who were seen in the emergency department of 32 tertiary hospitals in Brazil. Patients were characterized according to sex and other baseline characteristics and were classified according to previous anticoagulant use. The lack of anticoagulant use in patients with previous indications was analyzed. Statistical significance was set at 5%. RESULTS: The study data were from a total of 1955 patients enrolled. Male sex was more prevalent, and men were younger than the women. Due to an increased prevalence of previous AF episode and a higher CHA2DS2-VASc score, more women had indications for anticoagulant therapy; however, a significant proportion was not receiving this treatment. From 29 in-hospital deaths, 15 patients had previous indication for anticoagulation, but only 3 were using anticoagulants. CONCLUSION: This study revealed sex-related differences in the Brazilian population of patients with AF that are consistent with trends in high-income countries. The promotion of better implementation of anticoagulant and antithrombotic therapies to reduce the risk of death and thromboembolic events among women with AF in Brazil is crucial.


FUNDAMENTO: A fibrilação atrial (FA) é a arritmia cardíaca mais prevalente e sua apresentação difere de acordo com a idade e o sexo. Estudos recentes revelaram diferenças na FA entre vários grupos demográficos, incluindo a população latino-americana. OBJETIVOS: Melhor compreender as possíveis disparidades na prevalência da FA e nas estratégias de tratamento na população brasileira por meio de dados de um registro prospectivo multicêntrico de grande escala. MÉTODOS: O registro de FA da Rede D'Or é um estudo observacional prospectivo multicêntrico que incluiu pacientes com idade ≥ 18 anos com FA atendidos no pronto-socorro de 32 hospitais terciários no Brasil. Os pacientes foram caracterizados de acordo com o sexo e outras características basais e classificados de acordo com o uso prévio de anticoagulantes. Foi analisada a falta de uso de anticoagulantes em pacientes com indicações prévias. A significância estatística foi estabelecida em 5%. RESULTADOS: Os dados do estudo foram provenientes de um total de 1.955 pacientes inscritos. O sexo masculino foi mais prevalente e os homens eram mais jovens que as mulheres. Devido ao aumento da prevalência de episódios anteriores de FA e a um escore CHA2DS2-VASc mais elevado, mais mulheres tiveram indicação de terapia anticoagulante; no entanto, uma proporção significativa não estava recebendo esse tratamento. Dos 29 óbitos intra-hospitalares, 15 pacientes tinham indicação prévia para anticoagulação, mas apenas 3 estavam em uso de anticoagulantes. CONCLUSÃO: O presente estudo revelou diferenças relacionadas ao sexo na população brasileira de pacientes com FA que são consistentes com tendências em países de alta renda. A promoção de uma melhor implementação de terapias anticoagulantes e antitrombóticas para reduzir o risco de óbito e eventos tromboembólicos entre mulheres com FA no Brasil é crucial.


Asunto(s)
Anticoagulantes , Fibrilación Atrial , Tromboembolia , Humanos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Masculino , Femenino , Brasil/epidemiología , Anticoagulantes/uso terapéutico , Anciano , Persona de Mediana Edad , Factores Sexuales , Tromboembolia/prevención & control , Tromboembolia/epidemiología , Tromboembolia/etiología , Factores de Riesgo , Estudios Prospectivos , Distribución por Sexo , Prevalencia , Adulto , Anciano de 80 o más Años , Distribución por Edad
2.
Arq. bras. cardiol ; Arq. bras. cardiol;121(9): e20240310, 2024. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1573973

RESUMEN

Resumo Fundamento A fibrilação atrial (FA) é a arritmia cardíaca mais prevalente e sua apresentação difere de acordo com a idade e o sexo. Estudos recentes revelaram diferenças na FA entre vários grupos demográficos, incluindo a população latino-americana. Objetivos Melhor compreender as possíveis disparidades na prevalência da FA e nas estratégias de tratamento na população brasileira por meio de dados de um registro prospectivo multicêntrico de grande escala. Métodos O registro de FA da Rede D'Or é um estudo observacional prospectivo multicêntrico que incluiu pacientes com idade ≥ 18 anos com FA atendidos no pronto-socorro de 32 hospitais terciários no Brasil. Os pacientes foram caracterizados de acordo com o sexo e outras características basais e classificados de acordo com o uso prévio de anticoagulantes. Foi analisada a falta de uso de anticoagulantes em pacientes com indicações prévias. A significância estatística foi estabelecida em 5%. Resultados Os dados do estudo foram provenientes de um total de 1.955 pacientes inscritos. O sexo masculino foi mais prevalente e os homens eram mais jovens que as mulheres. Devido ao aumento da prevalência de episódios anteriores de FA e a um escore CHA2DS2-VASc mais elevado, mais mulheres tiveram indicação de terapia anticoagulante; no entanto, uma proporção significativa não estava recebendo esse tratamento. Dos 29 óbitos intra-hospitalares, 15 pacientes tinham indicação prévia para anticoagulação, mas apenas 3 estavam em uso de anticoagulantes. Conclusão O presente estudo revelou diferenças relacionadas ao sexo na população brasileira de pacientes com FA que são consistentes com tendências em países de alta renda. A promoção de uma melhor implementação de terapias anticoagulantes e antitrombóticas para reduzir o risco de óbito e eventos tromboembólicos entre mulheres com FA no Brasil é crucial.


Abstract Background Atrial fibrillation (AF) is the most prevalent cardiac arrhythmia, and its presentation differs according to age and sex. Recent studies have revealed differences in AF among various demographic groups, including the Latin American population. Objectives To better understand potential disparities in AF prevalence and treatment strategies in the Brazilian population through data from a large multicentric prospective registry. Methods The Rede D'Or AF registry is a multicenter prospective observational study including patients aged ≥ 18 years with AF who were seen in the emergency department of 32 tertiary hospitals in Brazil. Patients were characterized according to sex and other baseline characteristics and were classified according to previous anticoagulant use. The lack of anticoagulant use in patients with previous indications was analyzed. Statistical significance was set at 5%. Results The study data were from a total of 1955 patients enrolled. Male sex was more prevalent, and men were younger than the women. Due to an increased prevalence of previous AF episode and a higher CHA2DS2-VASc score, more women had indications for anticoagulant therapy; however, a significant proportion was not receiving this treatment. From 29 in-hospital deaths, 15 patients had previous indication for anticoagulation, but only 3 were using anticoagulants. Conclusion This study revealed sex-related differences in the Brazilian population of patients with AF that are consistent with trends in high-income countries. The promotion of better implementation of anticoagulant and antithrombotic therapies to reduce the risk of death and thromboembolic events among women with AF in Brazil is crucial.

3.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 31(4): 156-159, out.-dez. 2018. ilus
Artículo en Portugués | LILACS | ID: biblio-999206

RESUMEN

Introdução: A estimulação cardíaca temporária eventualmente é necessária por mais de 15 dias. Este contexto clínico está associado a complicações como o deslocamento de eletrodo e perfuração cardíaca, havendo a necessidade de reposicionamento ou troca de eletrodo. Além disto, os eletrodos e geradores convencionais para estimulação cardíaca temporária impõem ao paciente a restrição ao leito e suas consequências. Objetivo: avaliar um método previamente estudado de estimulação temporária relacionado à menor incidência de complicações e que permite a deambulação do paciente. Método: foram estudados 24 pacientes, entre janeiro de 2015 e dezembro de 2017, submetidos a implante de marcapasso provisório com o uso de eletrodo de fixação ativa. Resultados: a média de idade foi de 68,9 anos, e predominantemente do sexo masculino. O tempo médio de uso do marcapasso (MP) provisório foi de 9,7 dias, variando de dois a 28 dias. Durante um tempo total de 233 pacientes/ dia, não houve deslocamento de eletrodos, falhas de estimulação ou necessidade de revisão do sistema. Conclusão: a estimulação provisória utilizando eletrodos de MP definitivo de fixação ativa foi segura e impactou positivamente na qualidade de vida dos pacientes


Introduction: Temporary cardiac pacing is eventually required for more than 15 days. This clinical context is associated with complications such as electrode displacement and cardiac perforation, requiring repositioning or electrode replacement. In addition, conventional electrodes and generators for temporary cardiac stimulation force patients to stay in bed with its consequences. Objective: to evaluate a previously studied method of temporary stimulation related to a lower incidence of complications which allows patient to walk. Method: 24 patients were studied between January 2015 and December 2017, who underwent temporary PM implantation with the use of an active fixation electrode. Results: mean age was 68.9 years, and patients were predominantly male. The mean time of use of the temporary pacemaker (PM) was 9.7 days, ranging from two to 28 days. During a total time of 233 patients/ day, there was no electrode displacement, no stimulation failures or a need for system revision. Conclusion: Temporary stimulation using definitive PM fixation active electrodes was safe and had a positive impact on patients' quality of life


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Marcapaso Artificial , Estimulación Cardíaca Artificial/métodos , Electrodos , Prótesis e Implantes , Vena Subclavia , Bradicardia/diagnóstico , Estudios Retrospectivos , Desfibriladores Implantables , Bloqueo Atrioventricular , Atrios Cardíacos , Ventrículos Cardíacos , Venas Yugulares
7.
Arq. bras. cardiol ; Arq. bras. cardiol;103(6): 485-492, 12/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-732164

RESUMEN

Background: Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. Objective: To evaluate the impact of AF ablation on estimated LV filling pressure. Methods: A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. Results: One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Conclusion: Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure. .


Fundamento: A disfunção diastólica do ventrículo esquerdo (VE) está associada a novos episódios de fibrilação atrial (FA), e a estimativa das pressões de enchimento do VE através da razão E/e' está relacionada a um pior prognóstico em pacientes com FA. Entretanto, não se sabe se a restauração do ritmo sinusal pode reverter este processo. Objetivo: Avaliar o impacto da ablação da FA na estimativa da pressão de enchimento do VE. Métodos: Um total de 141 pacientes foi submetido à ablação por radiofrequência (RF) para o tratamento da FA refratária a drogas. Foi realizado ecocardiograma transtorácico 30 dias antes e 12 meses após a ablação. Foram avaliados os parâmetros funcionais do VE, volume do átrio esquerdo indexado (VAEi) e Doppler transmitral pulsado e Doppler tecidual do anel mitral (e' e E/e'). Dezoito pacientes apresentavam FA paroxística, 102 persistente e 21 pacientes FA persistente de longa duração. O acompanhamento incluiu ECG e monitoramento pelo sistema Holter 24h, 3, 6 e 12 meses após a ablação. Resultados: Cento e dezessete pacientes (82,9%) não apresentaram FA durante o acompanhamento (média de 18 meses ± 5 meses). O VAEi apresentou redução significativa no grupo com sucesso (30,2 mL/m2 ± 10,6 mL/m2 para 22,6 mL/m2 ± 1,1 mL/m2, p < 0,001) em comparação ao grupo sem sucesso (37,7 mL/m2 ± 14,3 mL/m2 para 37,5 mL/m2 ± 14,5 mL/m2, p = ns). A melhora da estimativa da pressão de enchimento do VE, avaliada através da redução na razão E/e', foi observada apenas após ablação com sucesso (11,5 ± 4,5 vs. 7,1 ± 3,7, p < 0,001), não sendo observada em pacientes com FA recorrente (12,7 ± 4,4 vs. 12 ± 3,3, p = ns). A taxa de ...


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Remodelación Atrial/fisiología , Ablación por Catéter/métodos , Función Ventricular Izquierda/fisiología , Análisis de Varianza , Fibrilación Atrial , Ecocardiografía , Electrocardiografía Ambulatoria , Estudios de Seguimiento , Variaciones Dependientes del Observador , Estudios Prospectivos , Volumen Sistólico/fisiología , Factores de Tiempo , Resultado del Tratamiento
8.
Epilepsy Res ; 108(6): 1026-31, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24836846

RESUMEN

BACKGROUND: Pharmacology frequently fails for the treatment of epilepsy. Although surgical techniques are effective, these procedures are highly invasive. We describe feasibility and efficacy of minimally invasive mapping and ablation for the treatment of epilepsy. METHODS: Mapping and radiofrequency ablations were performed via the venous system in eleven baboons and three dogs. RESULTS: Mapping in deep cerebral areas was obtained in all animals. High-frequency pacing was able to induce seizure activity of local cerebral tissue in 72% of our attempts. Cerebral activity could be seen during mapping. Ablative lesions were deployed at deep brain sites without steam pops or sudden impedance rise. Histologic analysis showed necrosis at the sites of ablation in all primates. CONCLUSION: Navigation through the cerebral venous system to map seizure activity is feasible. Radiofrequency energy can be delivered transvenously or transcortically to successfully ablate cortical tissue in this animal model using this innovative approach.


Asunto(s)
Ablación por Catéter/métodos , Corteza Cerebral/cirugía , Epilepsia/cirugía , Procedimientos Neuroquirúrgicos/métodos , Animales , Mapeo Encefálico , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Corteza Cerebral/irrigación sanguínea , Corteza Cerebral/patología , Corteza Cerebral/fisiopatología , Modelos Animales de Enfermedad , Perros , Epilepsia/patología , Epilepsia/fisiopatología , Estudios de Factibilidad , Campos Magnéticos , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Neuroquirúrgicos/efectos adversos , Procedimientos Neuroquirúrgicos/instrumentación , Papio
9.
Arq Bras Cardiol ; 103(6): 485-92, 2014 Dec.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-25590928

RESUMEN

BACKGROUND: Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. OBJECTIVE: To evaluate the impact of AF ablation on estimated LV filling pressure. METHODS: A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. RESULTS: One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m(2) ± 10.6 mL/m(2) to 22.6 mL/m(2) ± 1.1 mL/m(2), p < 0.001) compared to the non-successful group (37.7 mL/m(2) ± 14.3 mL/m(2) to 37.5 mL/m(2) ± 14.5 mL/m(2), p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). CONCLUSION: Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Remodelación Atrial/fisiología , Ablación por Catéter/métodos , Función Ventricular Izquierda/fisiología , Anciano , Análisis de Varianza , Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Volumen Sistólico/fisiología , Factores de Tiempo , Resultado del Tratamiento
10.
Rev. bras. ecocardiogr. imagem cardiovasc ; 26(2): 105-110, abr.-jun. 2013. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-678704

RESUMEN

Introdução: O aumento do átrio esquerdo (AE) está diretamente relacionado a disfunção diastólica do VE(VD) e ambos estão associados a ocorrência de fibrilação atrial (FA). Embora o diâmetro (DAE) seja mundialmente usado como medida do AE, muitas evidencias mostram que o volume indexado para a superficie corporea (indVAE) é mais acurado. Objetivo: Avaliar a correlação entre DAE e IndVAE em pacientes (pt) com DD. Material e Métodos: Dentre 892 pacientes encaminhados ao ecocardiograma, (ECO) de uma clínica terciaria no DF, entre janeiro de 2008 a junho de 2009, foram selecionados 540 com addos clínicos e ecocardiograficos, dos quais foram excluidos 21, devido a idade < 18 anos e 18 pacientes com lesão valvar mitral > discreta. A função diastólica foi considerada, significativamente, anormal se E/e'>-15 (elevação das pressões de encihmento ventricular esquerdo). A concordância entre as medidas de DAE e IndVAE foi avaliada da seguinte forma concordante (IndVAE<- 40mm ou IndVAE > 40); e discordante (indVAE<- 32 e DAE > 40 ou IndVAE > 32 e DAE <- 40.). Resultados: Dos 501 pacientes estudados, 33 (6,6%) tinham E/e' >- 15 e 468 (93,4%) E/e' < 15. Houve boa correlação entre DAE e IndVAE tanto para pacientes com E/e' >- 15 (r=0,57), quando para pacientes com E/e' < 15 (r=0,62). A discordância entre DAF e IndVAE foi maior nos pacientes...


Background: Increased left atrial (LA) is directly related to LV diastolic dysfunction (DD), and both are associated with atrial fibrillation (AF). Although the diameter (LAD) is used as a measure of LA, many evidences show that LA volume index (iLAV) is more accurate. Objective: To evaluate the correlation between LAD and iLAV in patients (pt) with DD. Material and Methods: Among 892 pt referred to the echocardiography laboratory of a tertiary clinic, from Jan/08 to June/09, 540 pt with clinical and echocardiographic data were selected and 21 were excluded for being <18yo and 18 pt presenting more than mild mitral valve lesion. Diastolic function was considered abnormal when E/e¡¯ ratio ¡Ý 15 (elevated left ventricular filling pressures). Agreement between measures of LAD and iLAV was evaluated: agreement if iLAV ¡Ü 32ml/m2 and LAD ¡Ü 40mm or iLAV > 32 and LAD > 40; and disagreement if iLAV ¡Ü 32 and LAD > 40 or iLAV > 32 and LAD ¡Ü 40. Results: Of 501 pt, 33 (6.6%) presented E/e¡¯ ratio ¡Ý 15 and 468 (93.4%) < 15. There was a good correlation between LAD and iLAV in both patients with E/e¡¯ ¡Ý 15 (r = 0.57), and E/e¡¯ < 15 (r = 0.62). The disagreement between LAD and iLAV was higher in p with E/e¡¯ ¡Ý 15 (21.2% vs 9% - p <0.0001). Clinical and echocardiographic data were, respectively, for E/e¡¯ ¡Ý15 and E/e¡¯ < 15: male 54.5% vs 45.5% (p = ns), age 73.2 ¡À 12.4 vs 50.1 ¡À 16.5 (p <0.0001), LAD (cm) 38.8 ¡À 6.3 vs 35.2 ¡À 5.2 (p <0.0001); iLAV (ml/m2) 35 ¡À 16.2 x 21.9 ¡À 7 (p <0.0001), EF (%) 60.7 ¡À 16.2 vs 70.7 ¡À 6.9 (p <0.0001), E/e¡¯ 21 , 1 ¡À 8.1 vs 16.5 ¡À 2.4 (p <0.0001), HBP 81.8% vs. 50.2% (p <0.0001), DM 21.2% vs. 9.4% (p = 0.04); CHF 24.2% vs. 3.2% (p <0.0001), CAD 33.3% versus 9% (p <0.0001). Conclusion: Patients with elevated left ventricular filling pressures are older, have larger LA diameter and volume, worse EF and higher incidence of HBP, diabetes, CHF and CAD. There is less agreement between LAD and iLAV in these patients.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Ecocardiografía Doppler/métodos , Ecocardiografía , Fibrilación Atrial/complicaciones , Función Atrial/fisiología , Atrios Cardíacos
11.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 26(2): 82-88, abr.-jun .2013.
Artículo en Portugués | LILACS | ID: lil-711866

RESUMEN

Objetivo: Avaliar a segurança e a eficácia da ablação por cateter de substrato endocárdico e epicárdico de pacientes com cardiomiopatia chagásica e taquicardia ventricular refratária ao tratamento farmacológico. Método: 34 pacientes foram incluídos no estudo. Durante o ritmo sinusal, foi realizado o mapeamento eletroanatômico (CARTO-XP) endoepicárdico de voltagem utilizando critérios padronizados (cicatriz < 1,5 mV). A estimulação programada foi usada para a indução de taquicardia ventricular e as arritmias estáveis foram submetidas a mapeamento de ativação e encarrilhamento. Nas arritmias instáveis, a saída do circuito foi definida pela estimulação e o mapeamento (pace mapping) na borda da cicatriz. A ablação foi realizada após definição do circuito e do substrato pelas técnicas descritas. Resultados: Foram realizados 34 procedimentos, com sucesso imediato de 79 por cento. Foi encontrada cicatriz epicárdica em 88 por cento dos pacientes. Não houve tamponamento cardíaco ou qualquer outra complicação grave relacionada ao procedimento. No seguimento de 12 meses, a taxa de recorrência foi de 15 por cento sem indução de taquicardia ventricular e três pacientes morreram devido a progressão da falência cardíaca. Conclusão: A ablação endocárdica e epicárdica foi segura e efetiva para o controle da taquicardia ventricular em pacientes com doença de Chagas.


Objective: Assess the safety and efficacy of endocardial and epicardial substrate catheter mapping and ablation of refractory ventricular tachycardia in patients with Chagas Disease. Patients and Methods: 34 patients were included in this study. During sinus rhythm, patients underwent epicardial and endocardial voltage electroanatomic mapping (CARTO) using standardized criteria (scar < 1.5 mV). Programmed ventricular stimulation was used to induce ventricular tachycardia and stable rhythms were submitted to activation and entrainment mapping. Exit of unstable arrhythmias was defined by stimulation and mapping (pace-mapping) in the scar border zone. Ablation was performed after definition of the circuit and substrate by the reported techniques. Results: 34 procedures were performed and immediate success was achieved in 79 percent. Epicardial scar was observed in 88 percent. There was no cardiac tamponade or major complications related to the procedure. During the 12 month follow-up the recurrence rate was 15 percent in the patients without ventricular tachycardia induction and three patients died due to progressive heart failure. Conclusion: In the study population, catheter ablation using epicardial and endocardial approach was safe and effective in ventricular tachycardia control in chagasic patients.


Asunto(s)
Humanos , Amiodarona/administración & dosificación , Cardiomiopatía Chagásica/terapia , Taquicardia Ventricular/diagnóstico , Ablación por Catéter/métodos , Electrocardiografía , Ecocardiografía/métodos , Espectroscopía de Resonancia Magnética , Estudios Prospectivos
12.
Rev. bras. anestesiol ; Rev. bras. anestesiol;62(6): 881-884, nov.-dez. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-659019

RESUMEN

JUSTIFICATIVA E OBJETIVOS: O relato de caso descreve uma situação rara e potencialmente fatal associada à administração de anestesia. Nosso objetivo foi discutir as causas de parada cardíaca súbita no período perioperatório em pacientes aparentemente saudáveis e a fisiopatologia das anomalias de origem das artérias coronárias como uma causa de parada cardíaca súbita. RELATO DE CASO: Uma mulher de 44 anos, sem sintomas prévios de doença coronariana ou arritmias, apresenta parada cardíaca súbita durante a instalação de anestesia geral em duas situações distintas. No primeiro episódio, a paciente apresentava-se com quadro de abdômen agudo, porém hemodinamicamente estável. Após a indução anestésica, ocorreu bradicardia e hipotensão arterial, refratárias à reposição de volume e vasopressores. O quadro evoluiu para assistolia. A paciente foi reanimada com sucesso e recebeu alta em boas condições. No segundo episódio, um ano após o primeiro, a paciente se encontrava em boas condições clínicas para feitura de uma cirurgia eletiva. Após a indução anestésica, a paciente desenvolveu taquicardia ventricular seguida por assistolia, que foi prontamente revertida. Após extensa investigação, foi identificada uma origem anômala da artéria coronária esquerda. CONCLUSÕES: Nosso relato é ilustrativo ao enfatizar que uma investigação diagnóstica minuciosa deve ser feita nos casos de parada cardíaca súbita perioperatória, mesmo em pacientes aparentemente saudáveis.


BACKGROUND AND OBJECTIVES: This case report describes a rare and potentially fatal condition associated with anesthesia administration. Our aim was to discuss the causes of sudden cardiac arrest during the perioperative period in apparently healthy patients and the pathophysiology of anomalous origin of the coronary arteries as a cause of sudden cardiac arrest. CASE REPORT: Female patient, 44 years old, with no previous symptoms of heart disease or arrhythmias, had a sudden cardiac arrest during general anesthesia in two different situations. In the first episode, the patient presented signs of acute abdomen, but remained hemodynamically stable. Following induction of anesthesia, the patient exhibited bradycardia and hypotension refractory to volume replacement and vasopressors. The condition progressed to asystole. The patient was successfully resuscitated and discharged from the hospital in good condition. In the second episode, one year after the first, the patient was in good clinical condition to undergo an elective surgery. After induction of anesthesia, the patient developed ventricular tachycardia followed by asystole, which was promptly reversed. After extensive investigation, an anomalous origin of the left coronary artery was identified. CONCLUSIONS: Our report is illustrative as it emphasizes that a thorough diagnostic investigation should be done in cases of sudden cardiac arrest during the perioperative period, even in patients that appear to be healthy.


JUSTIFICATIVA Y OBJETIVOS: El relato de caso describe una situación rara y potencialmente fatal asociada con la administración de anestesia. Nuestro objetivo fue discutir las causas de parada cardíaca súbita en el período perioperatorio en pacientes aparentemente sanos y la fisiopatología de las anomalías de origen de las arterias coronarias como una causa de parada cardíaca súbita. RELATO DE CASO: Mujer de 44 años, sin sintomatología anterior de enfermedad coronaria o arritmias, que presenta una parada cardíaca súbita durante la aplicación de la anestesia general en dos situaciones distintas. En el primer episodio, la paciente tenía un cuadro de abdomen agudo pero hemodinámicamente estable. Después de la inducción anestésica, ocurrió una bradicardia e hipotensión arterial, refractarias a la reposición de volumen y vasopresores. El cuadro evolucionó con asistolia. La paciente fue reanimada con éxito y recibió alta en buenas condiciones. En el segundo episodio, un año después del primero, la paciente estaba en buenas condiciones clínicas para la realización de una cirugía electiva. Después de la inducción anestésica, desarrolló una taquicardia ventricular seguida por asistolia, que fue rápidamente revertida. Después de una extensa investigación, fue identificado un origen anómalo de la arteria coronaria izquierda. CONCLUSIONES: Nuestro relato es ilustrativo porque enfatiza que una investigación diagnóstica minuciosa debe ser realizada en los casos de parada cardíaca súbita perioperatoria, incluso en los pacientes aparentemente sanos.


Asunto(s)
Adulto , Femenino , Humanos , Anestesia General , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/diagnóstico , Muerte Súbita Cardíaca/etiología
13.
Rev Bras Anestesiol ; 62(6): 878-84, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23176996

RESUMEN

BACKGROUND AND OBJECTIVES: This case report describes a rare and potentially fatal condition associated with anesthesia administration. Our aim was to discuss the causes of sudden cardiac arrest during the perioperative period in apparently healthy patients and the pathophysiology of anomalous origin of the coronary arteries as a cause of sudden cardiac arrest. CASE REPORT: Female patient, 44 years old, with no previous symptoms of heart disease or arrhythmias, had a sudden cardiac arrest during general anesthesia in two different situations. In the first episode, the patient presented signs of acute abdomen, but remained hemodynamically stable. Following induction of anesthesia, the patient exhibited bradycardia and hypotension refractory to volume replacement and vasopressors. The condition progressed to asystole. The patient was successfully resuscitated and discharged from the hospital in good condition. In the second episode, one year after the first, the patient was in good clinical condition to undergo an elective surgery. After induction of anesthesia, the patient developed ventricular tachycardia followed by asystole, which was promptly reversed. After extensive investigation, an anomalous origin of the left coronary artery was identified. CONCLUSIONS: Our report is illustrative as it emphasizes that a thorough diagnostic investigation should be done in cases of sudden cardiac arrest during the perioperative period, even in patients that appear to be healthy.


Asunto(s)
Anestesia General , Anomalías de los Vasos Coronarios/complicaciones , Anomalías de los Vasos Coronarios/diagnóstico , Muerte Súbita Cardíaca/etiología , Adulto , Femenino , Humanos
14.
Rev. bras. ecocardiogr. imagem cardiovasc ; 25(2): 91-96, abr.-jun. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-619138

RESUMEN

Objetivo: Avaliar os efeitos da terapia de ressincronização cardíaca no remodelamento reverso do átrio esquerdo e na função diastólica do ventrículo esquerdo. Método: Entre setembro de 2004 e junho de 2006, 22 pacientes (62 +- 14 anos, 12 homens, 52%), foram submetidos a terapia de ressincronização cardíaca por ICC CFIII/IV (NYHA), com tratamento clínico otimizado, QRS>120ms (151+- 20ms) e dissincronia ventricular ao ecocardiograma, A etiologia da ICC foi isquêmica em 10 pacientes, hipertensiva em 3, chagásica em 6, alcoólica em 1 e idiopática em 2 pacientes. Foram coletados dados clínicos e ecocardiográficos [diâmetros e volumes VE, FE, índice do volume AE (Índ VAE) e DTI do anel mitral (E' e E/E'), antes e até 90 dias após o procedimento. O volume do AE foi medido através da fórmula 8/3 ? [(A1 x A2)/L]. A dissincronia intraventricular foi avaliada pelo modo-M (atraso entre pico de contração septal e parede posterior - PP) e ao Doppler tecidual do miocárdio. Resultados: Não foram observadas complicações durante o procedimento. Houve melhora da CF (3,5 +-0,5 x 1,5+- 0,5 p>0,001), das medidas de função sistólica e dos índices de atraso inter e intraventricular em todos os pacientes. Houve redução significativa do Índ VAE (34,3 +- 17 x 21,8 +- 11 p<0,01) e da relação E/E' (16,4 +- 7,7 x 7 +- p<0,001. Conclusão: Neste estudo, a terapia de ressincronização cardíaca esteve associada a um remodelamento reverso do AE e uma melhora da função diastólica do VE.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Ecocardiografía/métodos , Ecocardiografía , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Contracción Miocárdica , Función Ventricular , Remodelación Ventricular , Ventrículos Cardíacos
15.
Circ Arrhythm Electrophysiol ; 4(2): 149-56, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21325208

RESUMEN

BACKGROUND: Luminal esophageal temperature (LET) monitoring is one strategy to minimize esophageal injury during atrial fibrillation ablation procedures. However, esophageal ulceration and fistulas have been reported despite adequate LET monitoring. The objective of this study was to assess a novel approach to LET monitoring with a deflectable LET probe on the rate of esophageal injury in patients undergoing atrial fibrillation ablation. METHODS AND RESULTS: Forty-five consecutive patients undergoing an atrial fibrillation ablation procedure followed by esophageal endoscopy were included in this prospective observational pilot study. LET monitoring was performed with a 7F deflectable ablation catheter that was positioned as close as possible to the site of left atrial ablation using the deflectable component of the catheter guided by visualization of its position on intracardiac echocardiography. Ablation in the posterior left atrial was limited to 25 W and terminated when the LET increased 2°C from baseline. Endoscopy was performed 1 to 2 days after the procedure. All patients had at least 1 LET elevation >2°C necessitating cessation of ablation. Deflection of the LET probe was needed to accurately measure LET in 5% of patients when ablating near the left pulmonary veins, whereas deflection of the LET probe was necessary in 88% of patients when ablating near the right pulmonary veins. The average maximum increase in LET was 2.5±1.5°C. No patients had esophageal thermal injury on follow-up endoscopy. CONCLUSIONS: A strategy of optimal LET probe placement using a deflectable LET probe and intracardiac echocardiography guidance, combined with cessation of radiofrequency ablation with a 2°C rise in LET, may reduce esophageal thermal injury during left atrial ablation procedures.


Asunto(s)
Fibrilación Atrial/cirugía , Temperatura Corporal , Quemaduras/prevención & control , Ablación por Catéter/efectos adversos , Fístula Esofágica/prevención & control , Esófago/lesiones , Monitoreo Intraoperatorio/métodos , Úlcera/prevención & control , Ultrasonografía Intervencional , Adulto , Anciano , Fibrilación Atrial/diagnóstico por imagen , Quemaduras/diagnóstico , Quemaduras/etiología , Ablación por Catéter/instrumentación , Catéteres , Distribución de Chi-Cuadrado , Diseño de Equipo , Fístula Esofágica/diagnóstico , Fístula Esofágica/etiología , Esofagoscopía , Esófago/diagnóstico por imagen , Esófago/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/instrumentación , Ontario , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Úlcera/diagnóstico , Úlcera/etiología , Ultrasonografía Intervencional/instrumentación
16.
Arq. bras. cardiol ; Arq. bras. cardiol;93(6): 666-671, dez. 2009. ilus
Artículo en Inglés, Español, Portugués | LILACS | ID: lil-542750

RESUMEN

Fundamento: O isolamento das veias pulmonares (IVP) tem sido usado como endpoint para a ablação da fibrilação atrial (FA) com cateter balão. Objetivo: Determinar a utilidade do ultrassom intracardíaco (USIC) para guiar o IVP, usando cateter balão a laser. Métodos: 59 VP foram ablacionadas em 27 cães. Imagens de Doppler foram usadas para identificar os vazamentos do fluxo sanguíneo entre a VP e o balão. Após cada liberação de energia, o cateter de mapeamento circular foi reposicionado para verificar se o isolamento tinha sido obtido. A posição de vazamento foi então correlacionada com a posição do gap no estudo patológico. A análise de regressão logística multivariada foi realizada. Resultados: Cinquenta e nove VP foram submetidas à ablação. O tempo médio de energia liberada foi de 279±177 seg., o diâmetro médio do balão era de 23±3 mm, e o comprimento médio do balão era 25±4 mm. O isolamento completo foi obtido em 38/59 (64 por cento), e foi significantemente mais comum sem vazamento: [30/38 (79 por cento) versus 8/23 (35 por cento), p<0,001]. Isso foi independente do tempo de aplicação (302±223 seg. vs. 266±148 sec., p=ns), potência (3,5 W/cm, 4,5 W/cm, e 5,5 W/cm), diâmetro do balão (24± 3 mm vs. 22± 3 mm, p= ns) e comprimento (27±4 mm vs. 24±4 mm, p=ns). O valor preditivo positivo para previsão de isolamento completo foi de 65 por cento e o valor preditivo negativo foi 83 por cento. Conclusão: Um vazamento identificável entre a VP e o dispositivo de ablação por cateter-balão observado no USIC é preditor de menor taxa de isolamento de VP mais baixas. O USIC pode ser útil para detectar vazamentos a fim de evitar o uso ineficaz de aplicação energia durante a ablação circunferencial da VP. Isto também pode ser útil quando outras energias são utilizadas.


Background: Pulmonary vein isolation (PVI) with balloon catheter has been used as the endpoint for AF ablation. Objective: To determine the usefulness of intracardiac ultrasound (ICUS) to guide PVI using laser balloon catheter. Methods: 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken. Results: 59 PV were ablated. Mean burn time was 279±177 sec, mean balloon diameter was 23±3 mm, and mean balloon length was 25±4 mm. Complete isolation was achieved in 38/59 (64 percent) cases, and it was significantly more common when there was no leak: [30/38 (79 percent) versus 8/23 (35 percent), p<0.001]. This occurred regardless of time of laser application (302±223 sec. vs. 266±148 sec., p=ns), laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm), balloon diameter (24± 3 mm vs. 22± 3 mm, p=ns) and length (27±4 mm vs. 24±4mm, p=ns). The positive predictive value for predicting incomplete isolation was 65 percent and the negative predictive value was 83 percent. Conclusion: An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.


Fundamento: Se usó el aislamiento de las venas pulmonares (AVP) como endpoint para la ablación de la fibrilación atrial (FA) con catéter-balón. Objetivo: Determinar la utilidad del ultrasonido intracardíaco (USIC) para guiar el AVP, usando catéter-balón láser. Métodos: Se ablacionaron 59 VP en 27 perros. Se usaron imágenes de Doppler para identificar los derrames del flujo sanguíneo entre la VP y el balón. Tras cada liberación de energía, se reposicionó el catéter de mapeamiento circular para verificar si se obtuvo el aislamiento. Se correlaccionó, entonces, la posición del derrame con la posición del gap en el estudio patológico. Se realizó el análisis de regresión logística multivariada. Resultados: Se sometieron 59 VP a la ablación. El tiempo promedio de energía liberada fue de 279±177 seg., el diámetro promedio del balón era de 23±3 mm, y la largura promedio del balón era 25±4 mm. Se obtuvo el aislamiento completo en 38/59 (64 por ciento), y fue significantemente más común sin derrame: [30/38 (79 por ciento) versus 8/23 (35 por ciento), p<0,001]. Eso fue independiente del tiempo de aplicación (302±223 seg. vs. 266±148 sec., p=ns), potencia (3,5 W/cm, 4,5 W/cm, y 5,5 W/cm), diámetro del balón (24± 3 mm vs. 22± 3 mm, p= ns) y largura (27±4 mm vs. 24±4 mm, p=ns). El valor predictivo positivo para la previsión del aislamiento completo fue del 65 por ciento y el valor predictivo negativo fue del 83 por ciento. Conclusión: Un derrame identificable entre la VP y el dispositivo de ablación por catéter-balón observado en el USIC es predictor de menor tasa del aislamiento de la VP más baja. El USIC puede ser útil para detectar derrames a fin de evitar el uso ineficaz de la aplicación de la energía durante la ablación circunferencial de la VP. Ello también puede ser útil cuando se utilizan otras energías.


Asunto(s)
Animales , Perros , Masculino , Ablación por Catéter/métodos , Complicaciones Intraoperatorias , Rayos Láser/efectos adversos , Venas Pulmonares/cirugía , Ultrasonografía Intervencional , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Métodos Epidemiológicos , Modelos Animales , Venas Pulmonares/lesiones , Venas Pulmonares , Ultrasonografía Doppler en Color/normas
17.
J Interv Card Electrophysiol ; 26(3): 195-205, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19757003

RESUMEN

BACKGROUND AND AIMS: Slow conduction scarred areas are related with ventricular tachycardia (VT) arrhythmogenesis in nonischemic cardiomyopathy. The purpose of this study was to characterize the substrate in both epicardial and endocardial surfaces of the left ventricle and to evaluate the effectiveness of substrate mapping and ablation for VT in Chagas cardiomyopathy. METHODS AND RESULTS: Seventeen patients were evaluated prospectively using a simultaneous epicardial and endocardial electroanatomical substrate mapping and ablation. With a mean of 201 +/- 94 epicardial and 169 +/- 77 endocardial points, the epicardial voltage areas < or =0.5 mV were 56.8 +/- 40.6 (range 4.4 to 154.8 cm(2)) as compared to 22.5 +/- 15.8 cm(2) (range 5.4 to 61.0 cm(2); p = 0.004) in the endocardium. Analyzing the epicardial surface, there was a strong correlation between the bipolar voltage electrograms and the electrogram duration at the epicardium during sinus rhythm (r = 0.897, p < 0.0001). Acute success was obtained in 83.3% of patients with no serious complications. At the end of follow-up from 14 patients with acute success, 11 (78.6%) had been event-free based on implantable cardioverter defibrillator (ICD) interrogation logs. CONCLUSION: Chronic Chagas cardiomyopathy patients have larger epicardial as compared to endocardial substrate areas. Combined epicardial endocardial substrate mapping and ablation during sinus rhythm proves effective in preventing VT recurrences and appropriate ICD therapies.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Cardiomiopatía Chagásica/complicaciones , Cardiomiopatía Chagásica/terapia , Desfibriladores Implantables , Taquicardia Ventricular/etiología , Taquicardia Ventricular/prevención & control , Adulto , Anciano , Enfermedad Crónica , Terapia Combinada , Endocardio/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardio/cirugía , Resultado del Tratamiento
18.
Future Cardiol ; 5(2): 191-9, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19371192

RESUMEN

Catecholaminergic polymorphic ventricular tachycardia occurs in healthy children and young adults causing syncope and sudden cardiac death. This is a familial disease, which affect de novo mutation in 50% of the cases. At least two causative genes have been described to be localized in the chromosome 1; mutation of the ryanodine receptor gene and calsequestrin gene. The classical clinical presentation is syncope triggered by exercise and emotion in children and adolescents with no structural heart disease. Polymorphic ventricular tachycardia during treadmill testing, or after isoproterenol infusion, is the most common feature. Therapeutic options include, beta-blockers, calcium-channel blockers and, an implantable cardioverter defibrillator is indicated in high-risk patients. Risk stratification of this disease is very challenging, since some risk factors proved to be useful in some series but not in others. However, family history of sudden cardiac death and symptoms initiated in very young children are important predictors.


Asunto(s)
Antagonistas Adrenérgicos beta/efectos adversos , Propranolol/efectos adversos , Taquicardia Ventricular/inducido químicamente , Antagonistas Adrenérgicos beta/administración & dosificación , Niño , Diagnóstico Diferencial , Relación Dosis-Respuesta a Droga , Electrocardiografía Ambulatoria , Resultado Fatal , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Propranolol/administración & dosificación , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología
19.
Arq Bras Cardiol ; 93(6): 616-21, 666-71, 2009 Dec.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-20379642

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) with balloon catheter has been used as the endpoint for AF ablation. OBJECTIVE: To determine the usefulness of intracardiac ultrasound (ICUS) to guide PVI using laser balloon catheter. METHODS: 59 PVs were ablated in 27 dogs. Doppler imaging was used to identify blood flow leaks between PV and balloon. After each energy delivery, the circular mapping catheter was repositioned to check if isolation had been achieved. The leak position was then correlated with the gap position at the pathological study. Multivariate logistic regression analysis was undertaken. RESULTS: 59 PV were ablated. Mean burn time was 279+/-177 sec, mean balloon diameter was 23+/-3 mm, and mean balloon length was 25+/-4 mm. Complete isolation was achieved in 38/59 (64%) cases, and it was significantly more common when there was no leak: [30/38 (79%) versus 8/23 (35%), p<0.001]. This occurred regardless of time of laser application (302+/-223 sec. vs. 266+/-148 sec., p=ns), laser power (3.5 W/cm, 4.5 W/cm, and 5.5 W/cm), balloon diameter (24+/- 3 mm vs. 22+/- 3 mm, p=ns) and length (27+/-4 mm vs. 24+/-4mm, p=ns). The positive predictive value for predicting incomplete isolation was 65% and the negative predictive value was 83%. CONCLUSION: An identifiable leak between PV and the LBA device seen at the ICUS is predictive of lower PV isolation rates. ICUS may be useful for leak detection to avoid ineffective energy application during circumferential PV ablation. This could also be helpful when other types of energy are used.


Asunto(s)
Ablación por Catéter/métodos , Complicaciones Intraoperatorias/diagnóstico por imagen , Rayos Láser/efectos adversos , Venas Pulmonares/cirugía , Ultrasonografía Intervencional , Animales , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Perros , Métodos Epidemiológicos , Masculino , Modelos Animales , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/lesiones , Ultrasonografía Doppler en Color/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA